Telebyte 458-LM-E8-36 Manual

Local loop simulator

Advertisement

Quick Links

"Results You Can Count On"
Model 458-LM-E8-36
Local Loop Simulator
0315-0361 Rev. A
Date of Publication: 11/06/07

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 458-LM-E8-36 and is the answer not in the manual?

Questions and answers

Summary of Contents for Telebyte 458-LM-E8-36

  • Page 1 “Results You Can Count On” Model 458-LM-E8-36 Local Loop Simulator 0315-0361 Rev. A Date of Publication: 11/06/07...
  • Page 2 Customer Support Thank you for your purchase of the Telebyte Model 458-LM-E8-36 Local Loop Simulator, featuring 36 MHz bandwidth and 8 channels for simulation of 0.4mm PE as specified in ANSI ETSI TS 101 388. Contact Information: Telephone E-mail/Internet General: 631-423-3232 support@telebytebroadband.com...
  • Page 3 TELEBYTE, INC. warrants its broadband simulation equipment to be free from defects in material and workmanship, under normal and proper use and in its unmodified condition, for 12-months, starting on the date it is delivered for use. TELEBYTE’S sole obligation under this warranty shall be to furnish parts and labor for the repair or replacement of products found by TELEBYTE to be defective in material or workmanship during the warranty period.
  • Page 4 Equipment Returns Out of warranty equipment may be returned, prepaid, to the Hauppauge, N.Y. customer service facility. Return shipping charges will be billed to the customer. The repaired unit will have a 90-day warranty. In those cases where "no trouble" is found, a reduced charge will be billed to cover handling, testing, and packaging.
  • Page 5: Table Of Contents

    Table of Contents 1.0 Introduction ..........................1-1 2.0 Specifications ..........................2-1 3.0 Connections..........................3-1 4.0 Control ............................4-1 4.1 Remote Commands........................4-1 4.1.1 RS-232/Ethernet Remote Commands ................4-1 4.1.2 IEEE 488 (GPIB) Remote Commands................4-4 4.2 Graphical User Interface......................4-9 4.2.1 Set Control Parameters ......................
  • Page 6: Introduction

    • Ability to open loop at either end of any channel • MAE <1 dB Figure 1: Front View of Model 458-LM-E8-36. Both the front and rear of the line module have 8 RJ-45 connectors. Model 458-LM-E8-36 Local Loop Simulator...
  • Page 7: Specifications

    > 90 dB Impedance Accuracy Typically +/- 10% 25 kHz to 36 MHz Maximum Voltage Tip – Ring 200 V Maximum Current 130 mA Connectors 8 RJ-45’s on front, 8 RJ-45’s on back Model 458-LM-E8-36 Local Loop Simulator Page 2-1...
  • Page 8: Connections

    LOCAL LOOP SIMULATOR FRONT REAR Open-loop Relay Open-loop Relay The Open-loop Relays are controlled by the “Connect Mode” part of the Set Length command. Refer to that command for options available. Model 458-LM-E8-36 Local Loop Simulator Rev - Page 3-1...
  • Page 9: Control

    4.0 Control The Model 458-LM-E8-36 can be controlled by RS-232 Remote Commands using a serial or Ethernet interface, IEEE488 Remote Commands, or a Telebyte GUI interface. In addition, manual control is provided through the LCD display and controls on the front panel of the Model 458-2SL (2-Slot chassis), 458-3SL (3-Slot chassis) and 458-CC-16/458-CM (16-Slot Chassis and Control Module).
  • Page 10 Set Length command sl:LM:H:LE,C Where: LM = Module slot number 01 - 02 (458-2SL) 01 – 03 (458-3SL) or 01 – 16 (458-CC-16) H = Channel number 1 - 8 LE = Length (in feet) Model 458-LM-E8-36 Local Loop Simulator Page 4-3...
  • Page 11 Example: rl:01:1 reports the length of channel 1 on the board in slot 1. Read the Lengths of all channels on one board command rl:LM:a Example: rl:01:a reports the lengths of all channels on the board in slot 1. Model 458-LM-E8-36 Local Loop Simulator Page 4-4...
  • Page 12: Ieee 488 (Gpib) Remote Commands

    Enable manual setting of lengths or configuration :lasterror Read last error Read description of last error *idn? Identify model no. and rev. Read model no. and software revision code *esr? Event Status Register read Read IEEE esr Model 458-LM-E8-36 Local Loop Simulator Page 4-5...
  • Page 13 Enables Event Status Bits as defined by the numerical value of the bits following the command. *ESE? Used to read the Enabling Bits in the Event Status Enable Register. *ESR? Reads the Event Status Enable Register. Model 458-LM-E8-36 Local Loop Simulator Page 4-6...
  • Page 14 P = connect CPE only CO is open. O = connect CO only CPE is open. Z = open both CO and CPE ends Example: :setcard:length:01:1:2250,n sets channel 1 of the line module in slot 1 to 2250 m. Model 458-LM-E8-36 Local Loop Simulator Page 4-7...
  • Page 15 Read the lengths of all channels on one board command :readcard:length:LM:a Example: :readcard:length:01:a Read the lengths of all channels on all boards command :readcard:length:all Read serial number of one line module command :readcard:sn:LM Read all serial numbers command :readcard:sn:all Model 458-LM-E8-36 Local Loop Simulator Page 4-8...
  • Page 16: Graphical User Interface

    4.2.1 Set Control Module Parameters Suggested Settings: Control Module Parameters Serial/GPIB: Serial Com Port/Address: 1 Baud Rate: 19200 HDx Slot: All Set Channels All HDx Channels: checked Model 458-LM-E8-36 Local Loop Simulator Page 4-9...
  • Page 17 Line Modules section. Please note that, while line modules other than the 458-LM-E8-36 may be installed, and therefore displayed, those line modules may not necessarily be able to be controlled by the 458-LM-HDx software.
  • Page 18: Manual/Keypad Controls

    Where X is the serial Baud Rate, choose one of the following: Switch 19.2k 9.6k 4.8k 2.4k 1.2k Switch IEEE Y is the IEEE address. Combining values of the switch settings as shown below sets the IEEE address Switch Value Ex. Address 10 Model 458-LM-E8-36 Local Loop Simulator Page 4-11...
  • Page 19: Lcd/Rotary Encoders (458-2Sl)

    Config button: Used to access a second menu on the front panel. The bottom of the LCD displays the communication settings used. The bottom encoder adjusts this value between GPIB address 1 and GPIB address 30, as well as RS-232 baud rates 19200, 9600,4800,2400,1200 and 600. Model 458-LM-E8-36 Local Loop Simulator Page 4-12...
  • Page 20: Lcd/Keypad (458-3Sl)

    4.3.3 LCD/Keypad (458-3SL) 4.3.4 LCD/Keypad (458-CC-16/458-CM) Model 458-LM-E8-36 Local Loop Simulator Page 4-13...
  • Page 21 3. Turn rotary encoder 2 (458-2SL) or press the Right arrow (all others) to increment the allowable line length for a given board:channel combination. The connect mode displays automatically. Allowable lengths (feet) All Channels: 0 to 2250 m in 150-m increments. Model 458-LM-E8-36 Local Loop Simulator Page 4-14...

Table of Contents