EN : AUTOMATIC DIGITAL BLOOD PRESSURE MONITOR Thank you for purchasing Automatic Digital Blood Pressure Monitor. It is mainly designed for general home use. Before using the device, please read this manual carefully to ensure proper and safe operation. Please take good care of the manual for future reference. We glad to give you advice and support.
Included in delivery 4. Motion detection • Blood pressure monitor B-BM02 1 pc. 5. 60 Memories / person ( 2 person ) 6. WHO Indicator • Upper arm cuff size 23-33 cm. 1 pc. 7. Use with batteries or USB •...
Notes on use Disposal in accordance with the Waste • In order to ensure comparable values, always measure Electrical and Electronic Equipment EC your blood pressure at the same time of day. Directive – WEEE • Before every measurement, relax for about five minutes. Dispose of packaging in an environmen •...
Page 5
• Cardiovascular diseases may lead to incorrect • Do not allow sustained pressure in the cuff or frequent measurements or have a detrimental effect on measurements. The resulting restriction of the blood measurement accuracy. The same also applies to very flow may cause injury.
Instructions for storage and maintenance • If a battery has leaked, put on protective gloves and clean the battery compartment with a dry cloth. • The blood pressure monitor is made from precision and • Protect batteries from excessive heat. electronic components.
3. Device description • Please dispose of the device in accordance with EC Directive – WEEE (Waste Electrical and Electronic Equipment). If you have any questions, please contact the local authorities responsible for waste disposal. Notes on electromagnetic compatibility • The device is suitable for use in all environments listed in these instructions for use, including domestic environments.
Information on the display: 4. Preparing the measurement Inserting the batteries Press the indicator on the battery cover and slide the cover off in the direction of the arrow Insert 4 “AA” size batteries, align the polarities of the battery. 1.
Display Setup Memory Deletion If the low battery indicator is permanently displayed, you can no longer perform any measurements and must It is essential to set the date and time. replace the batteries. Once the batteries have been Otherwise, you will not be able to save your measured removed from the device, the time must be set again.
5. Measuring blood pressure Blood pressure may vary between the right and left arm, which may mean that the measured blood pressure Ensure the device is at room temperature before values are different. Always perform the measurement on measuring. The measurement can be performed on the the same arm.
4. After having reached the anticipated value of inflation, the monitor starts to deflate automatically with a constant speed to detect your blood pressure and pulse. • Before the initial blood pressure measurement, make sure always to rest for about 5 minutes. Otherwise deviations can occur.
Motion detector The monitor will be automatically shut off in 2 minutes without operation. When the monitor can’t measure the The icon will show on display when device detect value correctly, the screen will display “E” icon. movement during measurement. Press ON/OFF button to shut off the monitor and wait for Evaluating results 4 to 5 minutes to start a new measurement.
Page 13
Life Guide for Hypertension Patients Risk indicator: • High blood pressure (Hypertension); The measurements can be classified and evaluated in A blood pressure of 140/90 or higher is considered high accordance with the following table. However, these blood pressure. High blood pressure (HBP) is a serious standard values serve only as a general guideline, as the condition that can lead to coronary heart disease, heart individual blood pressure varies in different people and...
6. Abnormal phenomenon and Solutions Troubleshooting Error Indicators Abnormal Potential cause Solutions Phenomenon Symbol Cause Solutions Replace old batteries with new Power on Low battery or wrong ones; Align the polarities of the Check the connection of the air doesn’t work polarities of batteries aligned Air tube plug is not battery correctly.
7. Maintenance and storage 8. Technical Specifications 1. Do not subject the monitor and package to shocks, Model No. B-BM02 such us dropping it onto the floor. System Fully Automatic inflation and 2. Do not submerge the device or any of the components deflation in water.
Page 16
Guidance and Manufacturer’s Declaration Important information regarding Electro Magnetic Compatibility (EMC) This product needs special precautions regarding EMC and needs to be installed and put into service according to the EMC information provided, and this unit can be affected by portable and mobile RF communications equipment.
Need help?
Do you have a question about the bluedot B-BM02 and is the answer not in the manual?
Questions and answers