4.4 User Menu 2
Date and Hour in this menu can be set time, date, month and year
Language
Radio control
2Ways2
Night Mode
Settings
Climatic
Summer-
Winter
Remote
thermostat
Temperature
scale
Service
Counters
Errors list
Secondary
Information
change the language of the display
if set OFF - there is no radio control
optional
set the time of beginning and end of the Night Mode and enable the settings by pressing and holding the
button 2.
An external probe Klimaworks can be bought as an accessory with the thermostove. This probe must be
placed at the coldest point outside of the house. With the probe connected and the climatic function ena-
bled, the parameter "Boiler thermostat" is not set manually, but changes dynamically according to the
outside temperature read by the probe.
The menu consists of 2 submenu:
• Enabled - ON, OFF (Boiler thermostat set manually);
• Comfort - is available only with the Climatic function enabled. It gives the possibility to modify the ther-
mostat temperature in the range ±20°C.
The Comfort mode is available only in the Winter mode (a snow flake symbol appears on the display).
If the system has a domestic hot water tank, the Winter mode manages both radiators heating and do-
mestic hot water. The Summer function manages only domestic hot water.
the menu to enable / disable the Room Thermostat from a remote thermostat
the menu to set Celsius or Fahrenheit scale
Ignitions
Number of ignitions made
Failed ignitions
Number of failed ignitions
Operation hours
Hours of operation in Normal, Modulation and Security mode
Menu for the exclusive use of the authorized technician Ungaro
information related to the real-time operation of the product