Three types of programming are available: Daily, Weekly, Week-end. After having chosen the
program:
• with the arrow buttons 6 or 4 select the time slot to program
• enter in modification mode by pressing the button 3 (the time slot starts to blink)
• modify the time with the buttons 6 or 4
• to save the programmation press the button 3
• enable (a "
Daily
Choose the day of the week and set the time slots for ignition and extinguishing.
Program
Chrono
Chrono at midnight
Set the hour of ON of the previous day, for example at 20:30. Set the hour for OFF of the
previous day
at 23:59. Set the hour for ON of the next day at 00:00. Set the desired hour for OFF of the
next day, for exapmle at 06:30. The appliance will start Tuesday at 20:30 and will shut down
Wednesday at 6.30.
Weekly
For each day of week the programming is the same
Week end
The same time slots for ignition and extinguishing on working days Monday-Friday and diffe-
rent operation time slots for Saturday and Sunday.
Night
In this menu can be set the time slot for Night Mode, the reduced operation mode. The programming is similar to the
Mode
one described in the Chrono Mode. To program the operation at midnight set the time slot ON until 23:59 with the next
operation starting at 00:00 and stopping at the desired hour.
In this menu can be activated the calculation of the pellet remaining in the tank basing on the current consumption. Four
levels of the tank load will be shown on the display: 100% (full tank), 75%, 50%, 25%, 0 (Refill menu disabled ). If you
wish to use the Refill function, every time after loading pellet, insert an approximate percentage of tank load. If the load
Refill
is the same as the last percent inserted manually, press and hold for 3 seconds the button ESC to confirm. During the
operation of the generator, the function "Refill" will show on the display an alert when the tank load is less than 20%.
After 3 hours this message becomes alarm Er18, this error appears when the pellet load in the tank is les than 10%.
Make sure to insert the correct percentage of the pellet loaded in the tank, otherwise can appear an alarm Er03 (load
overestimated).
Soft
The Soft Mode can be enabled and disabled in this menu. It introduces reduced power, without taking in consideration the
Mode
thermal request of the house.
" sign appears) or disable the time slot (a "
button 2.
" disappears) by pressing the
12
Monday
ON
OFF
09:30
11:15 √
00:00
00:00
00:00
00:00
Monday
Tuesday
Wednesday
Thursday
Friday
Mon-Fri
Sat-Sun