LG Therma V AHBW A0 Series Service Manual page 60

General svc manual
Table of Contents

Advertisement

Trouble Shooting Guide
Display
Title
code
24
Press S/W Open
Check Flow Chart
Is the wire connection
normal ?
Yes
Is the soldering
state of connector is
normal?
Yes
Is the SVC Valve
opened ?
Yes
Check the leakage of
refrigerant.
Check Pressure of
suction pipe
Check Pressure of
discharge pipe
Is it normal ?
Yes
Change main PCB 2
Copyright ©2013 LG Electronics. Inc. All right reserved.
Only for training and service purposes
Cause of error
• Low / High pressure
S/W open.
No
Correct connection
No
Re-soldering component
No
Open SVC Valve
No
Re-vaccuming system
and Re-charging
- 60 -
Check point & Normal condition
• Check the connection of "CN_PRESS"
• Check the SVC V/V open.
• Check the leakage of refrigerant.
CN_PRESS
LGE Internal Use Only