Murphy Bed Accessories Installation
Instruction Manual(Queen Vertical)
Note: If you encounter any problems with the installation, missing
or replacement parts, please Contact ROOMTEC.
Please also tell us your "ORDER ID," we will solve the issue for
you as soon as possible.
Customer Service: (800)209-3199 (MON -FRI 9:00am-5:00pm
Eastern Time) or hello@room-tec.com

Advertisement

loading
Need help?

Need help?

Do you have a question about the Murphy Bed Accessories and is the answer not in the manual?

Questions and answers

Summary of Contents for RoomTec Murphy Bed Accessories

  • Page 1 Murphy Bed Accessories Installation Instruction Manual(Queen Vertical) Note: If you encounter any problems with the installation, missing or replacement parts, please Contact ROOMTEC. Please also tell us your “ORDER ID,” we will solve the issue for you as soon as possible.
  • Page 2 Tools needed: Power Drill, Stud Finder, Tape Measure, Phillips-head Screwdriver, Flat-Head Screwdriver, #4 Allen Wrench, Clamps and Drill bits appropriate for your mounting surface see step 16 on page 9. Step 1: Replace all hardware on bed components except for the bed stops.Familiarize yourself with all components in Figure 1.
  • Page 3 Step 2: Lay 1/4 inch plywood mattress support (PART J) on inner bed frame and attach with screws do not glue. Screw ends of both mattress retaining straps thru 1/4 inch plywood (PART J) into inner wood bed frame,16 (sixteen) inch from front corners of face panel as shown. - 02 -...
  • Page 4 Step 3: Lay assembled FRAME and FACE PANEL face-down on a padded surface i.e.,blanket or rug. Assembled Step 4: Frame & Face Panel Lay cabinet verticals on finished (front) edge as shown. Step 5: Slide plastic spacers onto pivot bars. Step 6: Slide pivot bars into pivot holes in bed frame until no...
  • Page 5 Step 7: Snap the E-Clips in the grooves on both pivot bars. Step 8: Measure up and mark a reference point 15 inches from the end of the vertical. Measure up18 inches and 28 inches,mark and drill two pilot holes. Screw the headboard into place as shown using #8 x 2 inch screws.
  • Page 6 Step 9: With the bed face panel remaining face-down on padding, and legs in the closed position slowly and carefully rotate the cabinet verticals & the headboard assembly into its upright position. NOTE: To prevent damage to the legs be sure they are in the closed position when rotating the bed into the upright position.
  • Page 7 Step 11: Place bed cabinet 2 to 3 feet away from the wall,allowing enough room to comfortably work behind the bed cabinet. Step 12: With a helper holding the bed cabinet, allow the bed to recess back into the cabinet about three (3) inches.
  • Page 8 Step 13: With a helper securely holding the cabinet, pull the bed out of the cabinet 4 to 5 inches. Working from behind the cabinet,reattach the bed stops. FLOOR Step 14: If the room has existing base molding, make a cut at the bottom rear of the cabinet verticals to accommodate the existing base molding.
  • Page 9 Step 16 Is very,very important!!Your bed must be securely and correctly anchored to the wall to assure proper operation and to avoid possible injury. NOTE: When the bed is lowered, it wants to pull the bed cabinet down with it, so the bed cabinet MUST be securely anchored to the wall using the correct fasteners for your type of wall.
  • Page 10 Step 16: Mounting the bed cabinet to the wall If the wall has wood studs, use 3" coarse thread drywall screws or 3" lag screws: Locate and mark the centers of the studs in desired wall location using a good studfinder. Drill four (4) pilot holes through the rear rail of the bed header into the wall for a queen size bed.
  • Page 11 Step 17: Holding the bed face panel in the down position, place the innersping mattess on the bed and secure with elastic retaining straps. NOTE:When lowering the bed without the counter balance of the mattress it may seem very difficult...do not be concerned, once the mattress is placed on the bed it will function easily.
  • Page 12: Problem Solving

    Problem Solving Q: The gas spring won't hand-compress.. has it "frozen up?" A: The design and construction of the gas spring's internal parts won't allow it to "freeze up."Each gas spring contains a significant amount of pressure, so they cannot be compressed by hand. Please refer to assembly booklet,page 6-step 12.
  • Page 13 REPLACING THE COUNTER BALANCE GAS SPRING Do not attempt to compress the by any other means than the one described in the step below. Step 1: Remove the mattress and with the bed in the upright. closed position, remove the anchor screws from the top of the bed cabinet.
  • Page 14 Step 5: With your helper still holding the bed cabinet, allow the bed to pull back into the bed cabinet. It will recess about 3 inches into the bed cabinet. Step 6: At this point, the gas spring can be removed and replaced one at a time.