Advertisement

Quick Links

ADD-ON MODULE
NMEA2000 TO ETHERNET
CONVERTER
The easiest way to stay online.
Installation Manual
version 1.0

Advertisement

Table of Contents
loading

Summary of Contents for Locomarine NMEA2000

  • Page 1 ADD-ON MODULE NMEA2000 TO ETHERNET CONVERTER Installation Manual The easiest way to stay online. version 1.0...
  • Page 2 Read carefully. For better understanding check video tutorials on our website. Register your product for software update notifications. Thank you.
  • Page 3 The contents of this manual are well prepared by Locomarine Networks d.o.o. While we try to improve our equipment at all times, Locomarine Networks d.o.o. shall incur no liability based on contents, updates or modification of the contents, or the lack of contents in this manual.
  • Page 4 PREFACE SAFETY INSTRUCTIONS ELECTRICAL SHOCK HAZARD: Do not open enclosure of the equipment if you are not qualified to do it. TURN OFF THE POWER IMMEDIATELY IF WATER LEAKS INTO THE EQUIPMENT OR AN OBJECT DROPS INTO THE EQUIPMENT: Continue operating the equipment could cause electrical shock or fire. Contact your nearest distributor or dealer for service. DO NOT DISASSEMBLE THE EQUIPMENT OR MODIFY THE EQUIPMENT: Improper disassemble or modification could cause electrical shock, fire, or personal injury.
  • Page 5: Table Of Contents

    CONTENT INTRODUCTION ABOUT NMEA2000 TO ETHERNET CONVERTER WHAT IS IN THE PACKAGE WARRANTY WARRANTY TERMS INSTALLATION DEVICE INSTALLATION AND CONNECTION CONNECTING TO ON NMEA 2000 NETWORK CONNECTING TO ETHERNET NETWORK CONNECTING TO CONVERTER CONNECTION TO THE CONVERTER ETHERNET MODES OF THE Converter...
  • Page 6: About Nmea2000 To Ethernet Converter

    When shipped, all devices are wrapped in plastic bags that protect them from humidity. Devices are then placed into a cardboard box. 1 - NMEA2000 to Ethernet converter, NML-04, 1 pcs 2 - Manuals & control software (on USB stick), QIG-0...
  • Page 7: Warranty Terms

    CHAPTER 2 - WARRANTY 2.1. WARRANTY TERMS 1. The Device warranty is valid for two years from the date of purchase. If a Device was purchased in a retail store, the sales receipt may be requested when applying for a warranty claim. 2.
  • Page 8: Device Installation And Connection

    CHAPTER 3 - INSTALLATION 3.1. DEVICE INSTALLATION AND CONNECTION The Device requires no maintenance. When deciding where to install the Device, choose a dry mounting location. Do not place the Device where it can be flooded by water or exposed to rain or water spray.
  • Page 9: Connecting To Converter

    The internal web site of the Ethernet Converter should be opened. Use login admin and password admin to enter the administrative web site. In case of a wrong password please contact our support at support@locomarine.com It is possible that the connection will not be established due to network settings or you will open some other device in a web browser instead of the Ethernet Converter. Even in case of a successful connection, we strongly recommend you to read this entire Section to the end and change factory settings.
  • Page 10: Emergency Mode Of The Converter

    CHAPTER 4 - CONNECTION TO CONVERTER 4.3. EMERGENCY MODE OF THE CONVERTER Turn off the NMEA 2000 power supply and use the supplied paperclip to press and hold the hidden button before powering on. Release the button when the status LED (green) lights up (it will be constantly lit while the button is pressed).
  • Page 11: Troubleshooting Of Ethernet Connection

    CHAPTER 4 - CONNECTION TO CONVERTER 4.4. TROUBLESHOOTING OF ETHERNET CONNECTION The following step-by-step guide will help you to troubleshoot the network connection: 1. Be sure that the network (yellow) LED of the Converter is flashing chaotically every few seconds. Otherwise, see the Section II. 2.
  • Page 12: Converter Settings

    CHAPTER 5 - CONVERTER SETTINGS 5.1. CONFIGURATION OF APPLICATION PROTOCOLS Most marine applications support both TCP and UDP network protocols. TCP is a connection-oriented protocol. This means that the receiver must confirm reception of data before it gets the next packet of data, otherwise the sender repeats the transmission after a timeout. So, the second TCP connection doubles the network traffic and CPU load, despite the fact that both clients receive the same data.
  • Page 13: Nmea Settings And Autopilot Control

    CHAPTER 5 - CONVERTER SETTINGS Server #3 also supports the Debug and Memory data protocols. The Debug protocol is designed to diagnose hardware or software issues. The Memory protocol allows export of the vessel’s data from an internal memory to GPX (tracks), CSV (spreadsheets) or XML formats. With the factory settings, Converter has Server #1 enabled and pre-configured use of TCP port 1456 and the NMEA 0183 data protocol.
  • Page 14 CHAPTER 5 - CONVERTER SETTINGS The difference in the last two modes is that autopilot not only maintains the right direction to the waypoint, but also tries to follow the line from the previous to the next waypoint. Note that Converter server port must be configured to work in both directions (Bidirectional in factory settings) to allow control of autopilot from the application.
  • Page 15 CHAPTER 5 - CONVERTER SETTINGS It is impossible to switch from Track mode to Auto when the application controls the autopilot, because it will return it to the Track mode after a 5-second delay. To take control in an emergency, switch the autopilot to Standby mode.
  • Page 16 CHAPTER 5 - CONVERTER SETTINGS Syntax of NMEA 2000 (RAW protocol) filters You should be familiar with the NMEA 2000 Standard (can be purchased from National Marine Electronics Association, www.nmea.org) to operate with NMEA 2000 filters. These filters actually contain pairs of 29-bit message identifiers and a mask. The identifier is compared by processing the NMEA 2000 message identifier and the second value (mask) defines the comparison concerning which bits are significant.
  • Page 17: Web Gauge Setup

    CHAPTER 6 - WEB GAUGE SETUP 6.1. WEB GAUGES OF ADMINISTRATIVE WEB SITE The Web Gauges page (WG) allow real time viewing of vessel data using a web browser on PC, laptop, tablet or smartphone and can replace instrument displays. You can open the WG using the link on the logon page of the Converter’s administrative web site (no authorization is required) or, if you are logged in, using the Web Gauges menu item.
  • Page 18: Nmea2000 And Nmea0183

    CHAPTER 7 - NMEA2000 AND NMEA0183 7.1. NMEA 2000 MESSAGES SUPPORTED BY CONVERTER The Converter can pass any message from NMEA 2000 to a PC application and in the opposite direction. No in the table below means that the Device will not process these messages during service communication with other devices on the network.
  • Page 19 CHAPTER 7 - NMEA2000 AND NMEA0183 127488 Engine Parameters, Rapid Update RPM, XDR, DIN, PGN 127489 Engine Parameters, Dynamic XDR, DIN DIN and PGN are wrap NMEA 2000 messages according SeaSmart (v1.6.0) and MiniPlex 127493 Transmission Parameters, Dynamic DIN, PGN (v2.0) specifications.
  • Page 20 CHAPTER 7 - NMEA2000 AND NMEA0183 130311 Environmental Parameters XDR, MTW, MDA Device with factory settings perform conversion from true to apparent wind and vice versa. MWV sentence is sending twice (one for relative wind and one for true). Also used in MDA.
  • Page 21: Conversions From Nmea0183 To Nmea2000

    CHAPTER 7 - NMEA2000 AND NMEA0183 7.3. CONVERSIONS FROM NMEA0183 TO NMEA2000 NMEA0183 NMEA2000 Comment 129283 Cross Track Error Also used in PGN 129284 59904 ISO Request According SeaSmart.Net protocol specification v1.6.0 127488 Engine Parameters, Rapid Update 127489 Engine Parameters, Dynamic 127493 Transmission Parameters, Dynamic...
  • Page 22 CHAPTER 7 - NMEA2000 AND NMEA0183 126992 System Time The Device provides 50 milliseconds intervals between outgoing NMEA 2000 messages 127258 Magnetic Variation that are generated by more than one NMEA 0183 sentence. For example, a message with 129025 Position, Rapid Update PGN 129025 is generated only once if RMC and GLL are received withina 50 millisecond 129026 COG &...
  • Page 23: Drawing And Specification

    CHAPTER 8 - DRAWING AND SPECIFICATION 8.1. DIMENSION DRAWING 8.2. SPECIFICATIONS Supply voltage (from NMEA 2000 network): 7-17 V Current consumption (average): 48 mA Load Equivalency Number: 1 LEN Ethernet physical layer: 10/100 Base-T/TX Ethernet interface maximum speed: 100 Mb/s Ethernet galvanic isolation from NMEA 2000: 1500 V Internet protocol version: IPv4 TCP connections from applications (max.): 9...
  • Page 24 www.yachtrouter.com...

Table of Contents