Association (NFPA), the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities. 5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. 6. Ducted systems must always be vented to the outdoors. 1(844) 334-4203 support@thermomate.com...
Page 4
WARNING – TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE: A. Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings. 1(844) 334-4203 support@thermomate.com...
4 x M5Φ 0.2inch Washers 4 x Plastic wall anchors 4 x ST4 0.31inch 2 x Filters 1 x Ducting outlet 1 x User manual Check to make sure that all parts and accessories are present and in good condition. 1(844) 334-4203 support@thermomate.com...
*Duct Tape *Electrical tape Warning All electrical connections must be in accordance with local codes, ordinances, or national electrical codes. If you are unfamiliar with methods of installing electrical wiring, secure the services of a qualified electrician. 1(844) 334-4203 support@thermomate.com...
Page 7
National Fire Protection Association(NFPA), the American Society for Heating, Refrigeration and Air Conditioning Engineers(ASHRAE), and local code.When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities, Ducted systems must always be vented outdoors. 1(844) 334-4203 support@thermomate.com...
Installation Diagram For External Venting Wiring Diagram Caution! Shut-off power supply before installing. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes & standards, including fire-rated construction. 1(844) 334-4203 support@thermomate.com...
Page 9
2. Tap plastic wall anchors securely into each of the drilled holes. (Fig.1). 3. After wall anchors have been tapped in place, insert ST4x1.38inch woold screws to the top two wall anchors and tighten two screws. (Fig.1) Fig.1 1(844) 334-4203 support@thermomate.com...
Page 10
6. Lift the hood and hang the hood unit on the back wall using screws drilled in the wall. Once the hood is securely hung on the wall, tighten the screws from the interior of the hood after removing the filters. (Fig.4) Fig.4 1(844) 334-4203 support@thermomate.com...
Page 11
(Fig.6) Fig.6 Method 2:Mounting to the cabinet. To install the hood with a duct, you will need to provide a hole for the duct. Please use the template provided to correctly place the hole. (Fig.7) 1(844) 334-4203 support@thermomate.com...
Page 12
4. Pull the electrical cord through the bottom of the new cabinet hole. 5. Remove the filters and lift the hood and hang the hood unit on the bottom of the cabinet.And using 4pcs ST4x0.63inch self-tapping screw to drill in the cabinet plate. (Fig.7) 4-ST 4X16mm Fig.7 1(844) 334-4203 support@thermomate.com...
Press this button to stop the motor while it is running at any given speed. Caution: never put your hand inside of the unit while ti is operating. For the best performance clean your range hood regularly. 1(844) 334-4203 support@thermomate.com...
Page 14
3. Connect the lamp cable of the new light with the plug connection of the connection cable in the hood. 4. Press the lamp lightly into the hood housing and fix it by turning it slightly clockwise. 5. Dispose of the old lamp at an electronic waste disposal point. 1(844) 334-4203 support@thermomate.com...
A. Replace control panel or circuit board. The motor no Phillips screwdriver B. Replace with new motor longer runs. nose pliers gloves. assembly. A. Replace with a new LED light Light bulb went out. Gloves 1 watt max. 1(844) 334-4203 support@thermomate.com...