Dantel 44214 Installation & Operation Manual

9600 bps modem

Advertisement

Quick Links

About this Practice:
This practice has been reissued to:
• Update Figs. 1 and 3.
Reissued Practices: Updated and
new content can be identified by a
banner in the right margin.
Issue date: August 1998
Copyright 1998 by Dantel, Inc. • Dantel is a registered trademark of Dantel, Inc. • ISO 9001 Registered
9600 BPS M

Table of Contents

Ordering Information ........................................................................... 2
General Description .............................................................................. 2
Circuit Description ............................................................................... 3
Installation ............................................................................................ 5
Operation ............................................................................................ 10
Application Information ..................................................................... 10
Technical Specifications ..................................................................... 12
Warranty ............................................................................................. 14
CAUTION
Install or remove modules from the shelf only when the power is off.
If you install a module in the shelf with the power on, the internal
circuitry may suffer damage and the product warranty will be void.
Remove and install circuit boards only in a static-safe environment
(use antistatic wrist straps, smocks, footwear, etc.).
Keep circuit boards in their antistatic bags when they are not in use.
Do not ship or store circuit boards near strong electrostatic, electromag-
netic, magnetic, or radioactive fields.
For more complete information on electrostatic discharge safety
precautions, refer to Bellcore
Printed in the U.S.A.
I
NSTALLATION
44214
TM
Technical Reference # TR-NWT-000870.
& O
M
PERATION
ANUAL
44214-0898 <90-00005>
ODEM

Advertisement

loading

Summary of Contents for Dantel 44214

  • Page 1: Table Of Contents

    For more complete information on electrostatic discharge safety Issue date: August 1998 precautions, refer to Bellcore Technical Reference # TR-NWT-000870. Copyright 1998 by Dantel, Inc. • Dantel is a registered trademark of Dantel, Inc. • ISO 9001 Registered Printed in the U.S.A.
  • Page 2: Ordering Information

    On the data side of the 44214 there are input/output ports available for interfacing to Data Terminal Equipment. Available interfaces are: ♦...
  • Page 3: Circuit Description

    Loopback again. Both the analog and digital sides of the 44214 can be set to loopback. A two-position switch (S3) is used to enable or disable the analog side. A second two-position switch (S5) is used to enable or disable the digital side.
  • Page 4 CIRCUIT DESCRIPTION . 1 - F ; 44214 4-W UNCTIONAL CHEMATIC ODEM NOTE: The following are accessible through the front panel: S1, S3, S4, S5, R44, R53 +5VDC TTL / MODE CMOS GATING & DRIVERS MICRO CONTROLLER SIGNAL GROUND DLB 45...
  • Page 5: Installation

    Connection can be made at either of two places. A mini-plug can be inserted into the front panel jack labeled 4W MON or the meter can be connected to the 44214’s edge connector at pins 40 and 39. 44214-0898 <90-00005>...
  • Page 6 Figure 1. Edge connector pin 21 is the transmit into the test the facility between the mo- 44214. Pin 14 is the receive back to the dumb terminal. Use dem and the DTE device connect- pin 17 or 25 for signal ground.
  • Page 7 ORG mode and the other to ANS. These switches are on the front panel of each unit. Make sure that the 2W/4W switch (S7) is set per the application. . 3 - S TRAP AND WITCH OCATIONS 1 2 3 4 1 2 3 4 44214-0898 <90-00005>...
  • Page 8 180 ohm termination at RS-485 Transmit Data Input 1 & 2 Activated / DTR (*required for RS-422 or RS-485) 2 & 3 Not activated 1 & 2 Activated / RTS (*required for RS-422 or RS-485) 2 & 3 Not activated 44214-0898 <90-00005>...
  • Page 9 INSTALLATION When it is necessary to wire directly to the 44214 4-Wire Mo- dem, refer to Fig. 4 for the pin designation. . 4 - P ESIGNATIONS Reserved Reserved Reserved Reserved ALB (TTL) DLB (TTL) 4-Wire RCV or 2-Wire XMT/RCV...
  • Page 10: Operation

    MPORTANT When used in alarm applications, Fig. 5 shows a 44214 Modem application. A 44214 Modem at a as depicted in Fig. 5, the 44214 remote location transmits 460 Alarm and Control System data to has specific limitations.
  • Page 11 STATION 1 CODE STATION 1 CODE FIBER FIBER OPTIC OPTIC 41096-01 41096-01 TERM TERM CH 1 CH 1 DATA CIRCUIT REMOTE (CALLED) TERMINAL MASTER (CALLING) TERMINAL B18-05547-01 B18-05547-01 FIBER FIBER OPTIC OPTIC TERM TERM A11-44214-00 EXTERNAL FIBER 4-WIRE TERMINAL MODEM 44214-0898 <90-00005>...
  • Page 12: Technical Specifications

    TECHNICAL SPECIFICATIONS ; 44214 4-W ECHNICAL PECIFICATIONS ODEM DESCRIPTION VALUE POWER REQUIREMENTS Input Voltage -21 to -56 VDC Input Current @ -21 VDC 114 mA @ -24 VDC 100 mA @ -48 VDC 48 mA @ -56 VDC 45 mA...
  • Page 13 TECHNICAL SPECIFICATIONS ); 44214 4-W ECHNICAL PECIFICATIONS CONTINUED ODEM 9600 7200 4800 2400 1200 Configuration Mode V.32 9600 V.32 TCM V.32 4800 V.22 BIS 2400 V.22 BIS 1200 Modulation KPSK Carrier Frequency +0.01 1800 1800 1800 1200/2400 1200/2400 Baud (Symbol/Sec.)
  • Page 14: Warranty

    To ensure expedient processing of your order, provide a purchase order number and shipping and billing information when requesting an RMA number. Also, when the units are returned to Dantel, include a descrip- tion of the failure symptoms for each unit returned. Send defective equipment to: Dantel, Inc.

This manual is also suitable for:

A11-44214-00