The hysteresis prevents excessive switching when the current ambient brightness is close to the twilight
threshold.
Pos : 45.2.22 /#N eustruktur #/Onli ne-D okumentation (+ KNX)/Ü bers chriften (--> Für alle Dokumente <--)/3. Ebene/G - L/Leuchtmittel liegen i m Erfass ungs bereic h @ 24\mod_1338274997184_15.doc x @ 213894 @ 3 @ 1
Pos : 45.2.23 /#N eustruktur #/Onli ne-Hilfe/Powertool/Powertool 2/chm- Onli ne-Hilfe/App/D aemmerungssc hal ter ( AP- Wächter Basic / Pr emium)/Par ameter/Leuc htmittel liegen i m Erfassungs ber eich - DIN-A4 - ohne Obj ekte @ 28\mod_1346941028984_15.doc x @ 231178 @ @ 1
No:
No determination of the artificial light component (ambient brightness = total brightness)
Yes:
Artificial light component is calculated (Ambient brightness = total brightness - brightness of artificial light)
The calculation of artificial light is only required and practical when light sources that have been switched via the
bus and / or the movement detector lie within the detection range of the movement detector.
Pos : 45.2.24 /#N eustruktur #/Onli ne-D okumentation (+ KNX)/Ü bers chriften (--> Für alle Dokumente <--)/3. Ebene/M - O/Mindestdauer der U nterschr eitung @ 20\mod_1323253355893_15.doc x @ 111534 @ 3 @ 1
Pos : 45.2.25 /#N eustruktur #/Onli ne-Hilfe/Powertool/Powertool 2/chm- Onli ne-Hilfe/App/D aemmerungssc hal ter ( AP- Wächter Basic / Pr emium)/Par ameter/Mi ndestdauer der U ntersc hreitung - DIN-A4 - ohne Obj ekte @ 28\mod_1346941100746_15.doc x @ 231216 @ @ 1
A telegram will only be sent when the set time for the switching threshold has fallen short. This prevents false
triggering due to short-term changes in brightness.
Pos : 45.2.26 /#N eustruktur #/Onli ne-D okumentation (+ KNX)/Ü bers chriften (--> Für alle Dokumente <--)/3. Ebene/M - O/Mindestdauer der Ü bers chr eitung @ 20\mod_1323253357674_15.doc x @ 111542 @ 3 @ 1
Pos : 45.2.27 /#N eustruktur #/Onli ne-Hilfe/Powertool/Powertool 2/chm- Onli ne-Hilfe/App/D aemmerungssc hal ter ( AP- Wächter Basic / Pr emium)/Par ameter/Mi ndestdauer der Ü bersc hreitung - D IN-A4 - ohne Obj ekte @ 28\mod_1346941062660_15.doc x @ 231202 @ @ 1
A telegram will only be sent when the set time for the switching threshold has been exceeded. This prevents false
triggering due to short-term changes in brightness.
Pos : 45.2.28 /#N eustruktur #/Onli ne-D okumentation (+ KNX)/Ü bers chriften (--> Für alle Dokumente <--)/3. Ebene/M - O/Obj ekt Ausgang U mgebungshelligkeit ( Lux) @ 20\mod_1323253359362_15.doc x @ 111550 @ 3 @ 1
Pos : 45.2.29 /#N eustruktur #/Onli ne-Hilfe/Powertool/Powertool 2/chm- Onli ne-Hilfe/App/D aemmerungssc hal ter ( AP- Wächter Basic / Pr emium)/Par ameter/Obj ekt Ausgang U mgebungshelligkeit (Lux) - DIN- A4 - ohne Objekte @ 28\mod_1346941137055_15.doc x @ 231230 @ @ 1
Ambient brightness = total brightness - brightness of artificial light
To determine the brightness of the artificial light the twilight switch has several actuator inputs. Each time the
status changes, the resulting change in brightness is measured and the content of the artificial light recalculated.
Pos : 45.2.30 /#N eustruktur #/Onli ne-D okumentation (+ KNX)/Ü bers chriften (--> Für alle Dokumente <--)/3. Ebene/M - O/Obj ekt Eing ang H elligkeits-/D ämmer ungsschwelle @ 20\mod_1323253361205_15.doc x @ 111558 @ 3 @ 1
Pos : 45.2.31 /#N eustruktur #/Onli ne-Hilfe/Powertool/Powertool 2/chm- Onli ne-Hilfe/App/D aemmerungssc hal ter ( AP- Wächter Basic / Pr emium)/Par ameter/Obj ekt Ei ngang Hellig keits-/Dämmerungssc hwell e - DIN- A4 - ohne Objekte @ 28\mod_1346941231907_15.doc x @ 231244 @ @ 1
Adjusting range: 1 to 1000 lux
With this 2-byte float object the twilight threshold can be adjusted via the bus.
Pos : 45.2.32 /#N eustruktur #/Onli ne-D okumentation (+ KNX)/Ü bers chriften (--> Für alle Dokumente <--)/3. Ebene/S - T/Sc hwell e über Bus ei nler nbar (1 Bit) @ 20\mod_1323253444227_15.doc x @ 111566 @ 3 @ 1
Pos : 45.2.33 /#N eustruktur #/Onli ne-Hilfe/Powertool/Powertool 2/chm- Onli ne-Hilfe/App/D aemmerungssc hal ter ( AP- Wächter Basic / Pr emium)/Par ameter/Sc hwell e über Bus ei nler nbar (1 Bit) - DIN-A4 - ohne Obj ekte @ 28\mod_1346941270504_15.doc x @ 231258 @ @ 1
If an On telegram is received on this object, the currently measured ambient brightness value is taken over as
twilight threshold.