Note
The activation test also functions without programming.
Fig. 20: Control elements
To carry out the activation test, perform the following steps:
-
Set selector switch to T/S.
-
The device is now in test mode for 10 minutes (daytime operation, switch-off delay 2...9 seconds). In
addition, each detection is indicated by a special flashing of the status LED.
The device then switches back into standard operating mode (Standard operation = switch-off delay 3
min, brightness 5 lux).
-
To carry out an additional activation test, set the selector switch out of position T/S and then back to it or
interrupt the operating voltage supply for more than 15 seconds.
-
The device is now in test mode for another 10 minutes. Test mode is exited automatically after 10 minutes
or by adjusting the brightness.