7.
TROUBLESHOOTING GUIDE
SYMPTOM
Pump does not reach required
pressure
Pressure drops during use or
noisy pump
Motor does not start when
switched on
Motor hums but does not start
when switched on
The motor stops
Fluctuating pressure
Irregular jet
8.
DECLARATION OF CONFORMITY
Declaration of Conformity We, the sole importer into the UK of Sealey Power Products, declare that the product listed below is in conformity
with the following standards and directives.
Pressure Washer Model PC2950
73/23/EEC Low Voltage Directive
89/336/EEC EMC Directive
98/37/EC Machinery Directive
NOTE:
It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPORTANT: No responsibility is accepted for incorrect use of this equipment.
WARRANTY: Guarantee is 12 months from purchase, proof of which will be required for any claim.
INFORMATION: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.
01284 757500
REASON
Nozzle incorrect or worn
Dirty filter
Air being sucked into the system
Water pressure low
Worn or damaged pump components
Pump sucking air
Pump defect
Water too hot
Dirty filter
Plug is not connected
No electrical power
Unsuitable mains voltage
Pump is frozen
Incorrect extension cable
Tripped thermal overload due to
overheating
Inadequate water supply
Pump sucking air
Dirty filter
Dirt in high pressure nozzle of spray
gun
The construction file for this product is held by the Manufacturer and may
be inspected, by a national authority, upon request to Jack Sealey Ltd.
Signed by Mark Sweetman
For Jack Sealey Ltd. Sole importer into the UK of Sealey Power Products.
Sole U.K. Distributor, Sealey Group,
Bury St. Edmunds, Suffolk.
E-mail: sales@sealey.co.uk
01284 703534
REMEDY
Replace the nozzle
Clean filter
Check that hoses and fittings are air tight
Check that hoses/fittings are water tight and tap is fully open
Contact Authorised Service Agent
Check that hoses and fittings are air tight
Contact Authorised Service Agent
Reduce temperature
Clean or replace
Check plug connections and mains power supply is active
Check for adequate power supply and cable condition
Leave unit to thaw naturally. The pressure washer should be
protected from the threat of freezing. Extensive pump damage
could otherwise occur. (see Section 5 Note c).
Use a suitable extension cable. See Section 1 Elect.Safety.
Check that the mains voltage matches the specifications
Switch off the motor and let machine cool for 3 minutes
Fully open supply tap
Check that hoses and fittings are air tight
Check and clean
Clean with probe provided