  • Page 1 HY10000-WK08D Integrated Writer User’s Manual © 2023 HYCON Technology Corp. APD-HYIDE013-V06_EN www.hycontek.com...
  • Page 2: Table Of Contents

    Chip check(Blank Check) ........................16 Burning 6.3. chip (Program) ........................17 Check chip 6.4. (Verify) ..........................17 6.5. Read chip(Read) ..........................18 Automatic burning and reading 6.6. (AUTO) ..................18 6.7. Cautions .............................. 19 © 2023 HYCON Technology Corp APD-HYIDE013-V06_EN www.hycontek.com page2...
  • Page 3 Limitation of Programming Times ....................... 21 7.3. Cautions .............................. 21 MESSAGES DESCRIPTION ........................22 8.1. Information Messages Description ...................... 22 8.2. Error Messages Description ........................ 24 8.3. Cautions .............................. 27 REVISIONS ............................. 28 © 2023 HYCON Technology Corp APD-HYIDE013-V06_EN www.hycontek.com page3...
  • Page 4 HY10000-WK08D Integrated Writer User’s Manual Attention: 1. HYCON Technology Corp. reserves the right to change the content of this datasheet without further notice. For most up-to-date information, please constantly visit our website: http://www.hycontek.com. 2. HYCON Technology Corp. is not responsible for problems caused by figures or application circuits narrated herein whose related industrial properties belong to third parties.
  • Page 5: Package Contents

    Integrated Writer User’s Manual 1. Package Contents HY10000-WK08D integrated writer is a tool for connecting PC to program the chips. As shown in Figure 1-1, HYCON HY10P/HY11P/HY12P/HY13P/HY15P/HY17P/HY16F series products can be programmed through the integrated writer, the related hardware is...
  • Page 6: Safety Precautions

    When following status occurred, please remove the power supply immediately, and contact our engineer.  Power Supply line is worn or damaged.  Power source (battery) connected but no any light on while operating.  Component off. © 2023 HYCON Technology Corp APD-HYIDE013-V06_EN www.hycontek.com page6...
  • Page 7: Software Installation Requirements

    Windows XP, Windows Vista, Windows 7, Windows 8, Windows 10 (6) Apply the following interface modes: USB Port with “HID-compliant device” The HY10000-WK08D's USB Port driver uses the Windows standard “HID-compliant device”(Figure 3-1), so there is no need to install another USB driver.
  • Page 8: Hardware Version Requirements

    Firmware of HY16F series products uses V3.4(including) above 3.3. Firmware Version Conversion HY10000-WK08D integrated writer supports HY10P/HY11P/HY12P/HY13P/HY15P/ HY17P & HY16F series products, and it’s internal firmware can only be used for one family of products per conversion, before different firmware conversion, you can view the current firmware version through the “information 1”...
  • Page 9 USB cable and remove the short circuit. Figure 3-4 Note: For more information about the “Burner Transformer” software, please refer to the “APD-HYIDE014_EN” document ( HY10000-WK08x Integrated Writer Online Update Manual). © 2023 HYCON Technology Corp APD-HYIDE013-V06_EN www.hycontek.com page9...
  • Page 10: Writer Architecture

    HY10000-WK08D Integrated Writer User’s Manual 4. Writer Architecture 4.1. Architecture Description The HY10000-WK08D is a programming device between the Chips to be programmed and the writer software, the assembly diagram is as follows: Figure 4-1 4.2. Appearance introduction The integrated writer is a tool for programming chips, it can burn HY10P/ HY11P/ HY12P/HY13P/HY15P/HY17P &...
  • Page 11 Action success indicator (OK LED): Programming success message indicator. Action failure indicator (Error LED): This message indicator will be on in case of programming failure, blank checking failure and HAO frequency calibration failure. © 2023 HYCON Technology Corp APD-HYIDE013-V06_EN www.hycontek.com page11...
  • Page 12: Description Of Writer Characteristics

    Special programming software is provided for each Programming software product, which can download the code to be support version programmed to the Writer, to provide on-line or off-line programming function for the chip by the Writer. © 2023 HYCON Technology Corp APD-HYIDE013-V06_EN www.hycontek.com page12...
  • Page 13: Cautions

    LCM screen will display "Verifying….” string, If the check is passed, the "HYCON IDE" string will appear to ensure the correctness of the data, which means that the Writer can be started; if the check fails, the "Verify error 6" string will appear, which means that the code to be programmed is not correct, and the code to be programmed must be downloaded again.
  • Page 14: Programming Software Operation Instructions

    HY10000-WK08D Integrated Writer User’s Manual 5. Programming Software Operation Instructions Only 8-bit OTP chip is introduced below, for HY16F series products, please refer to "APD-HY16IDE006_EN" document directly. © 2023 HYCON Technology Corp APD-HYIDE013-V06_EN www.hycontek.com page14...
  • Page 15: On-Line (Pc) Programming Instructions

    When the file is successfully loaded into the burner or the Flash Memory of the IDE. The blank check, burn, verify, and read actions will be possible. If the file is not loaded successfully, the blank check, burn, verify, and read actions will not succeed. Figure 6-3 © 2023 HYCON Technology Corp APD-HYIDE013-V06_EN www.hycontek.com page15...
  • Page 16: Chip Check(Blank Check)

    Figure 6-7. Figure 6-7 If the chip is selected incorrectly or the check is not empty, the following message appears in the message bar, as shown in Figure 6-8. Figure 6-8 © 2023 HYCON Technology Corp APD-HYIDE013-V06_EN www.hycontek.com page16...
  • Page 17: Burning Chip (Program)

    Figure 6-11. Figure 6-11 If the chip is selected incorrectly or the programming is confirmed to be unsuccessful, the following message appears in the message bar, as shown in Figure 6-12. Figure 6-12 © 2023 HYCON Technology Corp APD-HYIDE013-V06_EN www.hycontek.com page17...
  • Page 18: Read Chip(Read)

    1, and the remaining programming times will be displayed in the message bar. Figure 6-14 If there is a failure, the entire process stops immediately and an error message is displayed in the message bar. © 2023 HYCON Technology Corp APD-HYIDE013-V06_EN www.hycontek.com page18...
  • Page 19: Cautions

    HY16F series programming function is different from 8-bit OTP chip products, which is not fully applicable to the above functions (such as no voltage, frequency calibration, etc.), please refer to HY16F series programming operation manual ( http://www.hycontek.com/ © 2023 HYCON Technology Corp APD-HYIDE013-V06_EN www.hycontek.com page19...
  • Page 20: Off-Line (Pc) Programming Instructions

    During Off-Line programming operation, it is necessary to download the programmed code (HEX or BIN file) into flash memory of the Writer, please refer to the user manual of Writer’s programming software. © 2023 HYCON Technology Corp APD-HYIDE013-V06_EN www.hycontek.com page20...
  • Page 21: Limitation Of Programming Times

    HY16F series programming function is different from 8-bit OTP chip products, which is not fully applicable to the above functions (such as no voltage, frequency calibration, etc.), please refer to HY16F series programming operation manual ( http://www.hycontek.com/ © 2023 HYCON Technology Corp APD-HYIDE013-V06_EN www.hycontek.com page21...
  • Page 22: Messages Description

    Press the Information button again to display the message of the (ST)Checksum of the download programming code of the Writer(and do the verification action) and the (RI)Checksum of the connected chip. ST Checksum=FFFF Information 6 : RI Checksum=FFFF © 2023 HYCON Technology Corp APD-HYIDE013-V06_EN www.hycontek.com page22...
  • Page 23  In Information 11-13, the set calibration message will be displayed, If all calibration functions are enabled, the following will be displayed: © 2023 HYCON Technology Corp APD-HYIDE013-V06_EN www.hycontek.com page23...
  • Page 24: Error Messages Description

    Error 6 Verification failed Verify Fail!  Error 7: Indicates that the set programming protection is not protected due to poor programming. © 2023 HYCON Technology Corp APD-HYIDE013-V06_EN www.hycontek.com page24...
  • Page 25 Communication error  Error 13: Only applicable to HY16F programming information description, indicating that chip has been programmed and protected. Chip has been protected © 2023 HYCON Technology Corp APD-HYIDE013-V06_EN www.hycontek.com page25...
  • Page 26 Writer is detected to be inconsistent with the calculated Checksum value, that is, the programming code loaded is wrong, and the programming code needs to be downloaded again. Error 19 Checksum error ckSum Mismatch © 2023 HYCON Technology Corp APD-HYIDE013-V06_EN www.hycontek.com page26...
  • Page 27: Cautions

    HY16F series programming function is different from 8-bit OTP chip products, which is not fully applicable to the above functions (such as no voltage, frequency calibration, etc.), please refer to HY16F series programming operation manual ( http://www.hycontek.com/ © 2023 HYCON Technology Corp APD-HYIDE013-V06_EN www.hycontek.com page27...
  • Page 28: Revisions

    HY10000-WK08D Integrated Writer User’s Manual 9. Revisions The following describes the major changes made to the document, excluding the font and punctuation changes. Version Page Date Revision Summary 2023/2/3 First edition © 2023 HYCON Technology Corp APD-HYIDE013-V06_EN www.hycontek.com page28...