EEPROM (IC402) writing procedure
1. Procedure to replace EEPROM and write initial value of microcomputer in EEPROM
(1) Replace EEPROM.
(2) Refer to the latest EEPROM data list.
(3) Start the test mode. (Refer to "How to enter the test mode".)
(4) Version display (At the time of settlement of the test mode by the button operation.)
[ V e r .
(5) The whole LCD lights.
(6) Test mode stop state.
[
T E S T
(7) Press the "BASS" button, and press 1 time the "SKIP DOWN" button.
[ E E P R O M ]
(8) Perform the operation to display "EEPROM SETTING MODE CHART", compare the EEPROM DATA LIST with the display,
and set according to the EEPROM DATA LIST with the VOL UP or VOL DOWN key.
(9) Set the temperature reference. (Refer to the Temperature Reference Setting Method.)
(10) Set according to the EEPROM DATA LIST.
(11) Press the stop button.
[
T E S T
(12) Press the stop button.
(13) After data is written in EEPROM, turn off power .
2. Temperature reference setting method
[1] Measurement, calculation and setting procedure
(1) Set the TEST mode.
(2) Start the EEPROM mode 'Temp' menu.
Key operation in order of BASS, SKIP-DOWN x 1 time, PLAY, PLAY in the test mode STOP state.
'TM$$%%' is displayed. ($$= Temperature code, %% = Temperature reference)
(3) Once press SKIP-UP, and determine the displayed microcomputer TEMP input AD value.
• 'TPin##' is displayed. (## = TEMP input AD value)
(4) At the ambient temperature, determine the temperature corrected value from the temperature measurement value
correction table.
(5) Determine the temperature reference, using the following formula.
• Temperature reference = Microcomputer TEMP input AD value + Temperature corrected value
(6)
Set the temperature reference value by button operation, and check whether the temperature code indication corresponds to "Temperature
Code Identification Table".
[2] Temperature measurement value correction table
Ambient
temperature
o
o
+ 9
C ~ +11
C
o
o
+12
C ~ +14
C
o
o
+15
C ~ +16
C
o
o
+17
C ~ +19
C
o
o
+20
C ~ +22
C
o
o
+23
C ~ +24
C
+25
o
C ~ +27
o
C
+28
o
C ~ +30
o
C
o
o
+31
C ~ +33
C
]
EEPROM version (C ~ Z)
Microcomputer ROM version
]
]
Temperature
Center
correction
temperature
- 05h
+ 10.0
- 04h
+ 12.7
- 03h
+ 15.4
- 02h
+ 18.2
- 01h
+ 20.9
± 00h
+ 23.6
+ 01h
+ 26.3
+ 02h
+ 29.0
+ 03h
+ 31.8
[3] Temperature code identification
Ambient
temperature
o
C
- 9
o
C ~ +10
o
C
+ 3
o
C ~ +21
o
C
+15
o
C ~ +33
o
C
o
+26
C ~ +43
o
C
o
C
o
C
o
C
o
C
– 17 –
MD-MT866H/MD-MT866W
Temperature
correction
o
C
08h
o
C
07h
o
C
06h
o
C
05h
Center
temperature
+ 0.5
o
C
+ 12.5
o
C
+ 23.6
o
C
o
+ 35.0
C

Advertisement