  • Page 1 OPERATOR’S MANUAL AUGER DRIVES X6075, X8075 High Torque & 8K2 Two Speed SERIAL NUMBER: ___________________ Manual Number: OM723 Part Number: 75623 MODEL NUMBER: ___________________ Rev. 6 800-456-7100 I www.paladinattachments.com 503 Gay Street, Delhi, IA 52223, United States of America Copyright © M-1644 3-6-20-9...
  • Page 3: Table Of Contents

    TABLE OF CONTENTS X6075, X8075 & 8K2 AUGER DRIVES PREFACE ................................3 SAFETY PRECAUTIONS SAFETY STATEMENTS ........................... 5 GENERAL SAFETY PRECAUTIONS ....................5-7 EQUIPMENT SAFETY PRECAUTIONS ....................8-9 DECALS ................................10 INSTALLATION ............................11-13 HYDRAULIC SYSTEM HOOK-UP INSTRUCTIONS ................. 14 OPERATING INSTRUCTIONS 8K2 TWO SPEED AUGER DRIVE ......................15 OPERATION ............................15-16 STORAGE ..............................16 LIFT POINTS ............................
  • Page 4 THIS PAGE IS INTENTIONALLY BLANK 75623...
  • Page 5: Preface

    Based on the uncertainty of the prime mover, operator, and job site, it is not possible to get precise ma- chine and operator sound pressure levels or vibration levels for this attachment. NOTE: A list of all Paladin Patents can be found at http://www.paladinattachments.com/patents.asp. M-1643...
  • Page 6 THIS PAGE IS INTENTIONALLY BLANK 75623...
  • Page 7: Safety Statements

    SAFETY STATEMENTS THIS SYMBOL BY ITSELF OR WITH A WARNING WORD THROUGHOUT THIS MANUAL IS USED TO CALL YOUR ATTENTION TO INSTRUCTIONS INVOLVING YOUR PERSONAL SAFETY OR THE SAFETY OF OTHERS. FAILURE TO FOLLOW THESE INSTRUCTIONS CAN RESULT IN INJURY OR DEATH. THIS SIGNAL WORD INDICATES A HAZARDOUS SITUATION WHICH, IF DANGER NOT AVOIDED, WILL RESULT IN DEATH OR SERIOUS INJURY.
  • Page 8 GENERAL SAFETY PRECAUTIONS WARNING! PROTECT AGAINST FLYING DEBRIS Always wear proper safety glasses, goggles, or a face shield when driving pins in or out, or when any operation causes dust, flying debris, or any other hazardous mate- rial. WARNING! LOWER OR SUPPORT RAISED EQUIPMENT Do not work under raised booms without supporting them.
  • Page 9 GENERAL SAFETY PRECAUTIONS WARNING! DO NOT MODIFY MACHINE OR ATTACHMENTS Modifications may weaken the integrity of the attachment and may impair the func- tion, safety, life, and performance of the attachment. When making repairs, use only the manufacturer’s genuine parts, following authorized instructions. Other parts may be substandard in fit and quality.
  • Page 10: Equipment Safety Precautions

    EQUIPMENT SAFETY PRECAUTIONS WARNING! KNOW WHERE UTILITIES ARE Observe overhead electrical and other utility lines. Be sure equipment will clear them. When digging, call your local utilities for location of buried utility lines, gas, water, and sewer, as well as any other hazard you may encounter. WARNING! EXPOSURE TO RESPIRABLE CRYSTALLINE SILICA DUST ALONG WITH OTHER HAZARDOUS DUSTS MAY CAUSE SE-...
  • Page 11 EQUIPMENT SAFETY PRECAUTIONS TRANSPORTING THE AUGER • Travel only with the earth auger in a safe transport position to prevent uncontrolled movement. Drive slowly over rough ground and on slopes. • Tether the earth auger with a chain, if necessary, to prevent uncontrolled swinging of the auger when moving from hole to hole.
  • Page 12: Decals

    DECALS GENERAL INFORMATION The following decals are reductions of the actual decals used on auger drives. Use this information to order replacements for lost or damaged decals. Be sure you understand all decals before operating the attachment. They contain information you need to know for attach- ment safety.
  • Page 13: Installation

    INSTALLATION INSTRUCTIONS GENERAL INFORMATION Find the mounting kit diagram and parts list for the kit you have received. Study the diagram and familiarize yourself with the names of the various parts. This knowledge will assist you in understanding these instructions. Read these instructions carefully before attempting to mount the auger.
  • Page 14 INSTALLATION INSTRUCTIONS Install the auger drive unit to pendulum mount with pivot pin provided with the drive unit assembly. Install the auger to the drive unit with the bolt and nut provided with the drive unit as- sembly. Refer to the “HYDRAULIC SYSTEM HOOK-UP” section in this manual for hydraulic connection instructions and recommendations.
  • Page 15 INSTALLATION INSTRUCTIONS Attach the swivel (#23835) to the mounting plate with pivot pin #23839 provided. Secure the pin in place with safety pin #10040. Install the drive unit to the swivel using the pin provided with the drive unit assembly. Install the auger to the drive unit with the bolt and nut provided with the drive unit as- sembly.
  • Page 16: Hydraulic System Hook-Up Instructions

    HYDRAULIC SYSTEM HOOK-UP INSTRUCTIONS GENERAL INFORMATION Once the installation instructions are complete, you are now ready to make the hydrau- lic connections necessary to operate your earth drill. READ AND UNDERSTAND SAFETY INFORMATION PRIOR TO MAKING HYDRAULIC CONNECTIONS. Your equipment dealer is in the best position to advise you as to where the best place on your machine is to make the hydraulic connections to power your earth drill drive unit.
  • Page 17: Operating Instructions

    OPERATING INSTRUCTIONS All three auger drives dig the same except the 8K2 has an additional two speed “shift on de- mand” feature. 8K2 TWO SPEED AUGER DRIVE: An increased demand on the auger drive will cause the pressure of the operating vehicle to in- crease.
  • Page 18: Storage

    OPERATING INSTRUCTIONS If necessary, repeat steps 7 & 8 to obtain a cleaner hole. In some soil conditions or when excessive down pressure is applied, auger may “screw” itself into the ground and become stuck causing earth drill to stall. If this happens, reverse the auger rotation (counter-clockwise) by moving the control valve lever to the reverse position and slowly raise the auger.
  • Page 19: Lift Points

    OPERATING INSTRUCTIONS LIFT POINTS Lifting points are identified by lifting decals where required. Lifting at other points is un- safe and can damage attachment. Do not attach lifting accessories around cylinders or in any way that may damage hoses or hydraulic components. • Attach lifting accessories to unit at recommended lifting points. • Bring lifting accessories together to a central lifting point. • Lift gradually, maintaining the equilibrium of the unit. WARNING! Use lifting accessories (chains, slings, ropes, shackles and etc.) that are capable of supporting the size and weight of your attachment. Secure all lifting accessories in such a way to prevent unintended disengagement. Failure to do so could result in the attachment falling and causing serious personal injury or death.
  • Page 20: Maintenance

    MAINTENANCE GENERAL INFORMATION Your McMillen earth drill was designed to be virtually maintenance free. Very little effort is needed to keep it in top working condition. It is however, important to follow these proce- dures to get full performance and longevity out of the unit. LUBRICATION Change planetary gear reduction oil with API-GL-5, 80W or 90W lubricant after the first 50 hours of operation and then every 1000 hours or 12 months, whichever comes first.
  • Page 21: Planetary Gearbox

    MAINTENANCE PLANETARY GEARBOX Change gear box oil using API-GL-5, 80W or 90W lubricant after the first 50 hours of operation and then every 1000 hours or 12 months, whichever comes first. Check oil level fre- quently to maintain proper lubrication. Oil should be at operating temperature when checking or changing gear box oil. NOTE: Place planetary in a horizontal position and wait 5 minutes before removing drain plug. This will give the oil a chance to drain from gears/bearings and therefore show an accurate oil level.
  • Page 22 THIS PAGE IS INTENTIONALLY BLANK 75623...
  • Page 23: Auger Options

    AUGER OPTIONS 2” HEX AUGERS AUGER SIZE (light to moderate (difficult ground (tree and shrub (soid, fracturable rock ground conditions) conditions) planting) & frozen grount) 4” x 3’ 20000 6” x 3’ 20018 20033 8” x 3’ 20053 20068 9” x 3’ 20092 20109 10”...
  • Page 24 AUGER OPTIONS 2.50” HEX AUGERS AUGER SIZE Standard Carbide Teeth Teeth 8” x 103” 40” of Flighting 20084 20085 9” x 103” 40” of Flighting 20132 20133 10” x 103” 40” of Flighting 20173 20174 12” x 103” 40” of Flighting 20221 20222 14”...
  • Page 25 AUGER OPTIONS EXTENSIONS ADAPTERS FIXED VARIABLE PART # DRIVE AUGER DESCRIPTION LENGTH LENGTH UNIT COLLAR 12” x 2” Hex 22839 23105 21969 2” HEX 2” ROUND 18” x 2” Hex 22845 23111 21987 2” HEX 2.56” ROUND 24” x 2” Hex 22851 23117 21989...
  • Page 26: Auger Wear Parts

    75623...
  • Page 27: Troubleshooting

    TROUBLESHOOTING PROBLEM POSSIBLE CAUSE POSSIBLE SOLUTION Slow Speed Low Flow Check with flow meter. If low investigate cause. Line restrictions Clear lines Fittings or connections too small Replace with proper sizes. Oil filter dirty Replace Hydraulic pump worn or See Dealer for repair damaged Insufficient Digging Worn teeth or point...
  • Page 28: Specifications

    SPECIFICATIONS GENERAL INFORMATION The X6075, X8075 and 8K2 augers require a heavy duty mounting kit with a maximum auger di- ameter of 48”. A hydraulic motor drives the auger through a sealed planetary gear reduction. The heavy duty gear design gives these units a long life with minimal maintenance and service costs. McMillen planetary drives are completely sealed with all moving components running in oil for total lubrication on a constant basis. All models feature reverse rotation for quick backout when obstructions are encountered. The system’s hydraulic relief valve protects the units from damage when the auger hits large immovable objects. DRAIN LINE REQUIRED DRAIN LINE REQUIRED MODEL X8075 MODEL X6075 Maximum Auger Diameter: 48” (1219mm) Maximum Auger Diameter: 48” (1219mm) Minimum Hydraulic Flow: 30 gpm (114 lpm) Minimum Hydraulic Flow: 36 gpm (136 lpm)
  • Page 29: Parts / Limited Warranty

    For Fax and E-mail Orders PLC_Sales@paladinattachments.com (734) 996-9014 WARRANTY In order to provide you with the most UP-TO-DATE Warranty information, Paladin Warranty Statement and Warranty Procedures along with Warranty Registration and Claim www.paladinattachments.com Forms have been moved to our website at...