Sirius Technologies ST303 User Manual

4-channel signal processing data logger

Advertisement

Quick Links

Sirius Technologies ST303 Data Logger
Signal Processing
Office: Jl. Radin Inten II No. 62 Duren Sawit, Jakarta 13440 - Indonesia
Workshop: Jl. Pahlawan Revolusi No. 22B, Jakarta 13430 - Indonesia
Phone: 021-8690 6777 (Hunting)
User Manual V1.0
ST303
4-Channel
Data Logger
Mobile: +62 816 1740 8925
Fax: 021-8690 6771
Fax: 021-8690 6777

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ST303 and is the answer not in the manual?

Questions and answers

Summary of Contents for Sirius Technologies ST303

  • Page 1 Sirius Technologies ST303 Data Logger User Manual V1.0 ST303 4-Channel Signal Processing Data Logger Office: Jl. Radin Inten II No. 62 Duren Sawit, Jakarta 13440 - Indonesia Mobile: +62 816 1740 8925 Workshop: Jl. Pahlawan Revolusi No. 22B, Jakarta 13430 - Indonesia...
  • Page 2: Table Of Contents

    Sirius Technologies ST303 Data Logger User Manual V1.0 Table of Content 1. Specifications, Dimension and Connections………….…Page 2 2. Data Logger Content………………………………………..Page 6 3. .Installation Requirement…………………………………..Page 7 4. Hardware Setup………………………………………………………..Page8 5. Software Installation………………………………………………..Page 9 6. Data Logger Setup………………………………………………….Page 12 7. Data Logger Data Download………………………………….Page 17 8.
  • Page 3 Sirius Technologies ST303 Data Logger User Manual V1.0 1. Specifications & Dimension 1.1.- Dimension 1.2.- Specifications Model # ST303 Type 4-Channel Signal Processing Channels Range -20°C to 70°C Temp. Accuracy ±0.7°C at 21°C Resolution 12 Bits Memory 128K Interface Serial/RS232...
  • Page 4 Sirius Technologies ST303 Data Logger User Manual V1.0 1.3.- Typical 4-Channel Connection...
  • Page 5 Sirius Technologies ST303 Data Logger User Manual V1.0 1.4-Voltage Connection Power supply 1.5.- Current Connection Power supply Sensor 1.6.- Temperature Sensor Connection...
  • Page 6: Data Logger Content

    Sirius Technologies ST303 Data Logger User Manual V1.0 2. Data Logger Content Model# Description Item ST303 Data Logger RS-232 Cable SF300 Installation Disk 0-10V Voltage Cable 4-20mA Cable Temperature Cable...
  • Page 7: Installation Requirement

    Sirius Technologies ST303 Data Logger User Manual V1.0 3. Installation Requirements: • Minimum system requirements for the software -Pentium III - 500 MHz processor or equivalent with 128 Megabytes of RAM. • Optimal Performance: -Pentium 4 - 2.8 gigahertz processor or equivalent with 256 Megs or ram •...
  • Page 8: Hardware Setup

    Sirius Technologies ST303 Data Logger User Manual V1.0 4. Hardware Setup 1. Connect one end of cable to the data logger. 2. Connect the RS-232 end of the cable to the computer. 3. 4-Channel sensor connection.
  • Page 9: Software Installation

    Sirius Technologies ST303 Data Logger User Manual V1.0 5. Software Installation A. Insert the CD into the disk drive.
  • Page 10 Sirius Technologies ST303 Data Logger User Manual V1.0 B. Click on Data logger setup to start installation.
  • Page 11 Sirius Technologies ST303 Data Logger User Manual V1.0 C. Follow the Installation Shield Wizard and click Finish to complete installation.
  • Page 12: Data Logger Setup

    Sirius Technologies ST303 Data Logger User Manual V1.0 6. Data Logger Setup 6.1.- The ST303 Series data logger requires the user to setup the data logger from the PC interface program. From the ST303 software main menu, Click on All programs, Click on Siriustech, Click on ST DATALOGGER, Click on ST Datalogger to start the PC program.
  • Page 13 Sirius Technologies ST303 Data Logger User Manual V1.0 Click on the icon to start the Setup menu. Click on Logger, click on Setup to enter the setup screen.
  • Page 14 Sirius Technologies ST303 Data Logger User Manual V1.0 6.2. Setup menu Figure 6.2- Setup Menu...
  • Page 15 Sirius Technologies ST303 Data Logger User Manual V1.0 Item Description Product Name Program will identify model # connected to the RS232 port Date Current computer date Maximum Record Maximum number of records can be store in number one data logger...
  • Page 16 Sirius Technologies ST303 Data Logger User Manual V1.0 Once the (9.)start date and (10)end date parameters have been selected, click (15)Save Setting to save the parameters to the data logger. If the (11)Delay Start Record box is checked, the logger will start according to the set start and end time.
  • Page 17: Data Logger Data Download

    Sirius Technologies ST303 Data Logger User Manual V1.0 7. Data Logger Data Download A. Click on the icon to start the Download menu. Click on Logger, Click Download Records to start the Download menu.
  • Page 18 Sirius Technologies ST303 Data Logger User Manual V1.0 7B. The software will try to establish the connection between PC and the data logger. Figure 7B-Establishing Connection...
  • Page 19 Sirius Technologies ST303 Data Logger User Manual V1.0 7C.- Data Logger Found. Figure 7C- Data logger Found.
  • Page 20 Sirius Technologies ST303 Data Logger User Manual V1.0 7D. Once the Connection is established, the software will automatically download all the records in the data logger to the PC. Figure 7D- Downloading Record...
  • Page 21 Sirius Technologies ST303 Data Logger User Manual V1.0 7.E. Once the download is competed, the software will prompt you to save an .adc file. The .adc file is for ST301 software use only. The retrieved data records are saved in .adc format. The saved file can later be downloaded back to the computer for graphic and data viewing.
  • Page 22 Sirius Technologies ST303 Data Logger User Manual V1.0 7.F. After the .adc file is saved, the retrieved data will be display in both the graphic and data format for viewing. Click on the any data record set (A), will correspond to the exact point on the graphic(B).
  • Page 23 Sirius Technologies ST303 Data Logger User Manual V1.0 7.G. Channel Selection Figure 7.G. Click on View, Click on Display Options to select Channel 1-4 to display on the screen. On the example, Channel 2 is selected. Office: Jl. Radin Inten II No. 62 Duren Sawit, Jakarta 13440 - Indonesia Mobile: +62 816 1740 8925 Workshop: Jl.
  • Page 24: Using Other Software Functions

    -The display data set can be send to the printer by click on the Print command. 4. Exit - Click on Exit the ST303 data logger program. B. Test COM Port Click on Logger, click on Test COM port to test the validity of the communication port.
  • Page 25: Warranty

    Sirius Technologies ST303 Data Logger User Manual V1.0 9. Warranty Sirius Technologies, Inc. equipment is warranted for a period of twelve (12) months from the date of purchase to be free of defects in material or workmanship. This warranty does not apply to damage resulting from accident, alteration, abuse, loss of parts or repair by other than Sirius Technologies, Inc.

Table of Contents