Sirius Technologies ST301U/ST302U USB Data Logger Operating Manual V1.0 1. Specifications Specifications Model # ST301U ST302U Type Temperature/Humidity Temperature Channels Range -20°C to 70°C -40°C to 85°C Temp. Accuracy ±0.7°C at 21°C ±0.7°C@25°C Humidity Range 0-100% RH Humidity Accuracy 2.5% Rh (20-80%Rh)
Sirius Technologies ST301U/ST302U USB Data Logger Operating Manual V1.0 2. Data Logger Content 1. Data Logger Unit 2. USB Cable 3. Installation Disk 3. Installation Requirements: Minimum system requirements for the software -Pentium III - 500 MHz processor or equivalent with 128 Megabytes of RAM.
Sirius Technologies ST301U/ST302U USB Data Logger Operating Manual V1.0 4. Hardware Setup 4.1.- Connect small end of cable to the data logger. 4.2.- Connect large end of the cable to PC’s USB port. 418-B Cloverleaf Dr. Baldwin Park, CA 91706...
Sirius Technologies ST301U/ST302U USB Data Logger Operating Manual V1.0 4.3.- Found New Hardware Window will identify ST300’s USB connection driver as” CP2103 USB to UART Bridge Controller” Fig. 4.3. 418-B Cloverleaf Dr. Baldwin Park, CA 91706 TEL:(626)934-0100 FAX:(626)934-0161 E-Mail: INFO@SIRIUSTEC.COM...
Sirius Technologies ST301U/ST302U USB Data Logger Operating Manual V1.0 4.4. Ready to Use Window will install the USB driver automatically. It only needs to install once. The message “Found New Hardware- Your new hardware is installed and ready to use.”...
Sirius Technologies ST301U/ST302U USB Data Logger Operating Manual V1.0 4.5. Driver Verification Click on Start, Click on Control Panel, Click on System, on click Hardware, Click on Device Manager, Click on Port(COM and LPT). Identify “CP210X USB to UART Bridge Controller”. If it’s there, the driver has been successfully installed.
Sirius Technologies ST301U/ST302U USB Data Logger Operating Manual V1.0 4.5.2. Correct USB Driver property Fig. 4.5.2. 418-B Cloverleaf Dr. Baldwin Park, CA 91706 TEL:(626)934-0100 FAX:(626)934-0161 E-Mail: INFO@SIRIUSTEC.COM...
Sirius Technologies ST301U/ST302U USB Data Logger Operating Manual V1.0 5. Software Installation 5.1. Insert the CD into the disk drive. Fig.5.1. 5.2. Click on Setup to start installation Fig. 5.2 418-B Cloverleaf Dr. Baldwin Park, CA 91706 TEL:(626)934-0100 FAX:(626)934-0161 E-Mail: INFO@SIRIUSTEC.COM...
Sirius Technologies ST301U/ST302U USB Data Logger Operating Manual V1.0 5.4. Select destination folder and click Next to continue. Fig. 5.4 5.5.-Click Next to continue 418-B Cloverleaf Dr. Baldwin Park, CA 91706 TEL:(626)934-0100 FAX:(626)934-0161 E-Mail: INFO@SIRIUSTEC.COM...
Sirius Technologies ST301U/ST302U USB Data Logger Operating Manual V1.0 Fig.5.5. 5.6. Installing program 418-B Cloverleaf Dr. Baldwin Park, CA 91706 TEL:(626)934-0100 FAX:(626)934-0161 E-Mail: INFO@SIRIUSTEC.COM...
Sirius Technologies ST301U/ST302U USB Data Logger Operating Manual V1.0 Fig.5.6 5.7. Installation completed. Click Finish to complete the setup program. 418-B Cloverleaf Dr. Baldwin Park, CA 91706 TEL:(626)934-0100 FAX:(626)934-0161 E-Mail: INFO@SIRIUSTEC.COM...
Sirius Technologies ST301U/ST302U USB Data Logger Operating Manual V1.0 Fig. 5.7. 6. Data Logger Setup 418-B Cloverleaf Dr. Baldwin Park, CA 91706 TEL:(626)934-0100 FAX:(626)934-0161 E-Mail: INFO@SIRIUSTEC.COM...
Sirius Technologies ST301U/ST302U USB Data Logger Operating Manual V1.0 6.1.-The ST300U series data logger requires the user to setup the data logger from the PC interface program. From Window’s start menu, Click on All programs, Click on Sirius Data logger, Click on ST300 DATA LOGGER to start the PC program.
Sirius Technologies ST301U/ST302U USB Data Logger Operating Manual V1.0 Fig.6.2.1 Fig. 6.2.2. Click on Logger, click on Setup to enter the setup screen. 418-B Cloverleaf Dr. Baldwin Park, CA 91706 TEL:(626)934-0100 FAX:(626)934-0161 E-Mail: INFO@SIRIUSTEC.COM...
Sirius Technologies ST301U/ST302U USB Data Logger Operating Manual V1.0 6.3. -. Setup menu Figure 6.3.- Setup Menu 418-B Cloverleaf Dr. Baldwin Park, CA 91706 TEL:(626)934-0100 FAX:(626)934-0161 E-Mail: INFO@SIRIUSTEC.COM...
Sirius Technologies ST301U/ST302U USB Data Logger Operating Manual V1.0 6.3.1. Data logger information and real-time display Fig.6.3.1 Product Name Model # Date Current Date and Time Maximum Record Number Maximum # of records can be stored in a data logger...
Sirius Technologies ST301U/ST302U USB Data Logger Operating Manual V1.0 6.3.2. Setting Menu Fig. 6.3.2. Parameter Settings 7. Description Enter data logger description 8. Interval(Duration) Select sampling Interval -2sec/3sec/4sec/5sec/6sec/7sec/8sec/9sec/10 sec 15sec/30sec/45 sec -1min/5min/10min/20min/30min -1hr/3hr/8hr 9. Start Time Data logger start record time(No user input) 10.
Sirius Technologies ST301U/ST302U USB Data Logger Operating Manual V1.0 6.3.3. Real-Time Graph Display Fig.6.3.3. 15. Temperature Real-Time Real-Time temperature display 16. Humidity Real-Time Real-Time Humidity display Display real-time temperature and humidity value from the data logger. 6.4. Using Delay Start 418-B Cloverleaf Dr.
Sirius Technologies ST301U/ST302U USB Data Logger Operating Manual V1.0 -Check Delay Start box. -The Start Date/Time window will light up. -Select the Start Date to start the data logger. -End Time will be computed automatically according to the start date/time and interval values.
Sirius Technologies ST301U/ST302U USB Data Logger Operating Manual V1.0 7. DATA Download 7.1. Click on the icon to start the Download menu. Fig.7.1 Click on Logger, Click on Download Records to start the Download menu. Fig. 7.1.1 418-B Cloverleaf Dr. Baldwin Park, CA 91706...
Sirius Technologies ST301U/ST302U USB Data Logger Operating Manual V1.0 7.2. The software will try to establish the connection between PC and the data logger. Fig. 7.2. 418-B Cloverleaf Dr. Baldwin Park, CA 91706 TEL:(626)934-0100 FAX:(626)934-0161 E-Mail: INFO@SIRIUSTEC.COM...
Sirius Technologies ST301U/ST302U USB Data Logger Operating Manual V1.0 7.2. Data logger Found. Fig. 7.3 418-B Cloverleaf Dr. Baldwin Park, CA 91706 TEL:(626)934-0100 FAX:(626)934-0161 E-Mail: INFO@SIRIUSTEC.COM...
Sirius Technologies ST301U/ST302U USB Data Logger Operating Manual V1.0 7.4. Save the data in .adc file format. Fig.7.4- (Enter .adc file name) 418-B Cloverleaf Dr. Baldwin Park, CA 91706 TEL:(626)934-0100 FAX:(626)934-0161 E-Mail: INFO@SIRIUSTEC.COM...
Sirius Technologies ST301U/ST302U USB Data Logger Operating Manual V1.0 7.5. Downloading Record Fig. 7.5 Once the connection is established, the software will automatically download all the records in the data logger to the PC. 418-B Cloverleaf Dr. Baldwin Park, CA 91706...
Sirius Technologies ST301U/ST302U USB Data Logger Operating Manual V1.0 7.6. Download success. Fig. 7.6 Data is downloaded to the PC. It’s ready for viewing. Click OK to view the data. 418-B Cloverleaf Dr. Baldwin Park, CA 91706 TEL:(626)934-0100 FAX:(626)934-0161 E-Mail: INFO@SIRIUSTEC.COM...
Sirius Technologies ST301U/ST302U USB Data Logger Operating Manual V1.0 7.7.Viewing Data Fig. 7.7 The right column is for data display. The left column is for data graphic display. Move the cursor up or down to scroll through the data. The black data line corresponds to the high- lighted data entry.
Sirius Technologies ST301U/ST302U USB Data Logger Operating Manual V1.0 8. Using Other Software Functions 8.1. FILE 8.1.1.Open -Click on Open to open the file in .adc format. 8.1.2. Export Data to Excel File -Save download data in Excel format. 8.1.3. Print Data -Print data in data format.
Sirius Technologies ST301U/ST302U USB Data Logger Operating Manual V1.0 8.2.1. Setup -Click Setup to enter Setup screen 8.2.2. Download Records -Click Download to Download screen 8.2.3. Test COM Port -Test available COM port 418-B Cloverleaf Dr. Baldwin Park, CA 91706...
Sirius Technologies ST301U/ST302U USB Data Logger Operating Manual V1.0 8.2.3. Test COM Port COM Port available. Fig. 8.2.3. 418-B Cloverleaf Dr. Baldwin Park, CA 91706 TEL:(626)934-0100 FAX:(626)934-0161 E-Mail: INFO@SIRIUSTEC.COM...
Sirius Technologies ST301U/ST302U USB Data Logger Operating Manual V1.0 8.2.4. COM port not available. Fig.8.2.4. 418-B Cloverleaf Dr. Baldwin Park, CA 91706 TEL:(626)934-0100 FAX:(626)934-0161 E-Mail: INFO@SIRIUSTEC.COM...
Sirius Technologies ST301U/ST302U USB Data Logger Operating Manual V1.0 8.3. View Click on Temp(F) or Temp(C) to change temperature unit. 418-B Cloverleaf Dr. Baldwin Park, CA 91706 TEL:(626)934-0100 FAX:(626)934-0161 E-Mail: INFO@SIRIUSTEC.COM...
Operating Manual V1.0 9. Warranty Sirius Technologies, Inc. equipment is warranted for a period of twelve (12) months from the date of purchase to be free of defects in material or workmanship. This warranty does not apply to damage resulting from accident, alteration, abuse, loss of parts or repair by other than Sirius Technologies, Inc.
Need help?
Do you have a question about the ST301U and is the answer not in the manual?
Questions and answers