CEFLA PURE 500 Operating Manual

Water demineralizer

Advertisement

Quick Links

WATER DEMINERALIZER
PURE
500
OPERATING MANUAL

Advertisement

Table of Contents
loading

Summary of Contents for CEFLA PURE 500

  • Page 1 WATER DEMINERALIZER PURE OPERATING MANUAL...
  • Page 3: Table Of Contents

    INSTALLATION ......................9 GENEraL PrECaUTIoNS ................9 SaFETY PrECaUTIoNS ................. 9 INSTaLLING THE oSmoTIC mEmBraNE CarTrIDGE ......11 CoNNECTING PUrE 500 To aUToCLaVES ..........16 CoNNECTING To THE WaTEr maINS ............18 OPERATION ......................21 FIrST STarTING .................... 21 PrECaUTIoNS To PrEVENT WaTEr STaGNaTIoN ....... 21 APPENDIX A - TECHNICAL CHARACTERISTICS ..........
  • Page 5: Introduction

    INTRODUCTION Dear Customer, Thank you for choosing a product. We hope that you will find it completely satisfactory. This manual describes all procedures for the correct installation and use of the equipment. Should you have any questions or suggestions concerning this product or our support, do not hesitate to contact us.
  • Page 6: Purpose Of The Manual

    WARNING! THE FaILUrE To oBSErVE THE aBoVE, rELEaSES THE maNUFaCTUrEr From aLL LIaBILITY. WARNING THE WaTEr ProDUCED BY PUrE 500 CaNNoT BE USED For FooD PUrPoSES.
  • Page 7: Contents Of The Package

    (see the accompanying document); that there is no obvious product damage. DImENSIONS AND WEIGHT Size and weight Pure 500 Height mm 490 Width mm 295...
  • Page 8: Description Of The Contents

    DESCRIPTION OF THE CONTENTS 1) Demineralizer body; 2) osmotic membrane cartridge; 3) wrench for fitting/removing the osmotic membrane vessel; 4) 2 PIPU unions for 1/4” Ø tube 5) net minifilter; 6) 1/2” female - 3/4” male reducer; 7) safety valve (WATER BLOCK®) with filter and adjustment wrench; 8) 3/4”...
  • Page 9: Product Presentation

    Pure 500 is a reverse osmosis demineralizer, a natural addition to the range of steam sterilizers. It has an elegant and compact design that combines ease of use and high reliability. PRESENTATION Pure 500 is hence an interesting option for users that require professional devices with an excellent quality/ price/performance ratio. mAIN PERFORmANCES Pure 500 has been designed to demineralize mains drinking water for subsequent automatic feeding into steam sterilizers.
  • Page 10 BOTTOm Serial number label REAR Support feet Filter drain valve Solenoid valve bypass outlet tap...
  • Page 11: Installation

    ProVIDE FUrTHEr INFormaTIoN. GENERAL PRECAUTIONS Install Pure 500 on autoclaves using the accessories provided with the demineralizer; do not install in humid or poorly ventilated environments; do not install in environments where there are flammable and/or explosive gases or vapours;...
  • Page 12 Listed below are the actions to take in the event of contact with the activated carbon filter contained in Pure 500. RISKS ON CONTACT Contact with the eyes. Possible temporary irritation because of abrasive dust. Contact with the skin. Possible temporary irritation because of abrasive dust.
  • Page 13: Installing The Osmotic Membrane Cartridge

    INSTALLING THE OSmOTIC Take the osmotic membrane cartridge and the vessel fitting/removing wrench out of the accessory kit: mEmBRANE CARTRIDGE a) Undo the screws (1) that secure the cover to the frame of the demineralizer using a cross-head screwdriver (not provided). B) Lift the plastic cover (2) of the demineralizer and place it on a flat surface.
  • Page 14 (9) from the coupling. D) Using both hands, grip the membrane vessel (4) positioned horizontally in the front part of the deminerali- zer and remove it from the brackets (5) fitted on the Pure 500 frame.
  • Page 15 E) Unscrew the head (4a) of the osmotic membrane vessel (4) using the wrench (10) contained in the acces- sory kit. F) remove the protective bag of the osmotic membrane cartridge (11). G) Insert the osmotic membrane cartridge (11) in the osmotic membrane vessel (4). H) Screw on the head (4a) of the osmotic membrane vessel (4) using the wrench (10).
  • Page 16 I) Refit the osmotic membrane vessel (4) in the brackets on the frame. L) Insert the tube (9) in the quick-coupling (8) on the head (4A) of the osmotic membrane vessel (4), then fit the safety clip (7) on the coupling.
  • Page 17 (2) and fasten it to the frame with the screws (1) WARNING DUrING INSTaLLaTIoN, PUT THE PLaSTIC CoVEr BaCk oN THE DEmINEraLIzEr ONLY AFTER HaVING CorrECTLY FoLLoWED THE INSTrUCTIoNS For oPENING aND CLoSING THE TaPS oN THE PUrE 500 BoDY, INDICaTED IN THE ProCEDUrE “FIrST STarTING” (Par. 5.1).
  • Page 18: Connecting Pure 500 To Autoclaves

    CONNECTING PURE 500 TO Pure 500 must be installed on the right-hand side of the autoclaves using the devices that form part of the AUTOCLAVES standard equipment of the demineralizer. m) Take the following out of the accessory kit: - the filling tube (3 m, 1/4” Ø) - 1 spigot union for 1/4”...
  • Page 19 - tube (7) = 30 cm - tube (8) = 20 cm q) Fasten one end of the tube (7) to the demineralized water outlet quick-coupling of Pure 500 and then fasten the other end to the minifilter inlet quick-coupling provided (10)..
  • Page 20: Connecting To The Water Mains

    CONNECTING TO THE WATER For Pure 500 to function it needs to be connected to a mains drinking water tap using the devices supplied mAINS standard with the demineralizer: T) Take the following out of the accessory kit: - the 1/2” female-3/4” male reducer;...
  • Page 21 W) Fasten the other free end of the tube (17) to the Pure 500 (19) inlet.
  • Page 22 ) Fasten one end of the tube (30) to the wastewater outlet quick-coupling (32) of Pure 500, then fasten the other end to the intermediate quick-coupling (33). ) Take a spigot union for 1/4” tube (35) and, after removing the clip and cap, insert it in the free outlet union on the rear wall of the autoclave.
  • Page 23: Operation

    Connect the plug (38). OPERATION In order to start using the Pure 500 demineralizer, all the installation phases must have been correctly FIRST STARTING carried out: a) fitting of the osmotic membrane cartridge (par. 4.3.); B) connection of the autoclaves (par. 4.4.);...
  • Page 24: Appendix A - Technical Characteristics

    APPENDIX A - TECHNICAL CHARACTERISTICS SUmmARY TABLE model PUrE 500 CEFLA s.c. Headquarters manufacturer Via Selice Provinciale 23/A – 40026 Imola (BO) IT operating temperature +5°C ÷ +30°C Storage temperature +5°C ÷ +30°C Dimensions (L x D x H) x 328 mm...
  • Page 25: Appendix C - Manteinance

    Turn off the autoclave. B) Drain out the autoclave filling tank (see the sterilizer user manual). C) remove the plastic cover of Pure 500: - undo the screws that secure it to the frame of the demineralizer using a cross-head screwdriver (not provided);...
  • Page 26 D) open the drain and close the outlet. E) Remove the three vertical filter cartridges (SEDIMENT + ACTIVATED CARBON + IONIC EXCHANGE rESIN) from the relative quick-coupling heads positioned on the frame of the demineralizer. - Dry off any water that has spilled out with a cloth; - dispose of the three quick-coupling filter cartridges in compliance with the regulations in force.
  • Page 27 F) Take the new set of quick-coupling filter cartridges (SEDIMENT + ACTIVATED CARBON + IONIC EXCHAN- GE rESIN) and screw them into the respective heads on the frame of the demineralizer. sediment activated carbon ionic exchange resin G) oSmoTIC mEmBraNE CarTrIDGE rEPLaCEmENT Take the vessel fitting/removing wrench out of the accessory kit and remove the exhausted cartridge found inside the vessel.
  • Page 28 H) rEPLaCING THE INLINE rESIN CarTrIDGE - Release the cartridge from the clips that join it to the osmotic membrane cartridge vessel. - remove the tubes that connect the resin cartridge to the hydraulic circuit of the demineralizer. - Unscrew the quick-couplings fitted on the two heads of the resin cartridge. - Dry off any water that has spilled out with a cloth.
  • Page 29 I) When you have finished changing the cartridges, open the tap on the solenoid valve and drain water for about 15 minutes to clean the cartridges. L) When rinsing is complete, close the tap on the solenoid valve. m) Close the drain and open the outlet.
  • Page 30 N) reposition the plastic cover on the frame of the demineralizer and secure it with the screws previously removed in point (C). o) Turn on the sterilizer. P) Wait for automatic filling of the demineralized water tank of the sterilizer.
  • Page 31: Appendix C - Manteinance

    APPENDIX C - mANTEINANCE WATER BLOCK SAFETY ® VALVE mAINTENANCE It is recommended to clean the filter at the inlet to the WaTEr BLoCk valve periodically. ® Carefully follow the instructions in the instruction leaflet contained in the relative package. PERIODIC CHECK OF THE WARNING! ANTI-BACKFLOW DEVICES...
  • Page 32: Appendix D - Troubleshooting

    APPENDIX D - TROUBLESHOOTING If the demineralizer does not function properly, carry out the following checks before calling Technical Service: WARNING POSSIBLE CAUSE ACTION -The demineralizer is working but is producing The message “H2O quality insufficient” is shown demineralized water with conductivity values -Replace the ionic exchange resin cartridges.
  • Page 33: Appendix Z - Customer Support

    IN OR OUT OF WARRANTY, DIRECTLY CONTACT THE TECHNICAL SUPPORT DEPARTmENT OF THE DEALER OR RESELLER THAT SUPPLIED THE PRODUCT. CEFLA S.C. will gladly provide any information you may need on the product as well as give you sugge-stions and advice on the steam sterilization procedures.