Summary of Contents for Samsung AW CGHLAWKNTC Series

  • Page 1 Air conditioner User & installation manual AW**CGHLAWKNTC • purchasing this Samsung air conditioner. • operating this unit, please read this manual carefully and retain it for future reference.
  • Page 2 AW07CGHLAWKNTC AW09CGHLAWKNTC AW12CGHLAWKNTC...
  • Page 4 Introduction to Refrigerants R32 Installation & Assembly Instructions Appearance cleaning Front panel cleaning and drying...
  • Page 5 Introduction to Refrigerants R32 The refrigerants used for air conditioners are environmentally friendly hydrocarbons R32. This kind of erant is combustible and odorless. Moreover, it can burn and explode under certain condition. However, there will be no risk of burning and explosion if you comply with the following table to install your air conditioner in a room with an appropriate area and use it correctly.
  • Page 6 The following checks shall be applied to installations using flammable refrigerants: -- The charge size is in accordance with the room size within which the refrigerant containing parts are installed; -- The ventilation machinery and outlets are operating adequately and are not obstructed; -- If an indirect refrigerating circuit is being used, the secondary circuit shall be checked for the presence of refrigerant;...
  • Page 7 as the chlorine may react with the refrigerant and corrode the copper pipe-work. If a leak is suspected, all naked flames shall be removed/ extinguished. If a leakage of refrigerant is found which requires brazing, all of the refrigerant shall be recovered from the system, or isolated (by means of shut off valves) in a part of the system remote from the leak.
  • Page 8 complete with pressure-relief valve and associated shut-off valves in good working order. Empty recovery cylinders are evacuated and, if possible, cooled before recovery occurs. The recovery equipment shall be in good working order with a set of instructions concerning the equipment that is at hand and shall be suitable for the recovery of all appropriate refrigerants including, when applicable, flammable refrigerants.
  • Page 9 Warnings Please read the manual before installation, using, maintenance. Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer. Do not pierce or burn the appliance. The appliance shall be stored in a room without continuous operating sources (for example: open flames, an operating ignition gas appliance or an operating electric heater.) Please contact the nearest after-sale service center when maintenance is necessary.
  • Page 10 Failure to follow these instructions may lead to incorrect operation, causing harm and damage. indications:...
  • Page 13 Installation & Assembly Instructions Before installing the appliance, you must read the manual carefully to get the safety information and notes. When filling the combustible refrigerant, any of your rude operations may cause serious injury or injuries to human body or bodies and object or objects. A leak test must be done after the installation is completed.
  • Page 14 Control Panel Without timer setting,the Digital Display: operation mode is Cooling,Dry, Fan and Auto,and the set temperature will be displayed. Time will be displayed under timer setting. Press the mode button to cycle 2. Mode Button: through the various modes: Cool, Dry, Fan and Auto.
  • Page 15 Control Panel 9. Fan Speed Button: Press the FAN SPEED button 5. Eco: When the unit is in ECO mode, the light to choose the fan speed options. You can choose will turn on. In ECO mode, the unit will turn off Hi, Med, Lo or auto speed in COOL mode and once the room is cooled to the user set choose Hi, Med, Lo in FAN mode.
  • Page 16 Remote controller 5. Timer: Use these buttons on the control panel and remote to set the Timer. Timer Off: The timed stop is programmed by pressing TIMER button. Set the rest time by pressing the button until the rest time displayed is to your demand then press TIMER button again.
  • Page 17 5K/6K 406 × 306 × 390 472 x 338 x 396 7K/9K 502 x 372 x 546...
  • Page 18 Remove the filter by pulling down on the indents of the filter door on the front of the unit. Appearance cleaning Please soak the soft cloth in warm water. Be sure to wring it out and wipe it. If the dust on the front panel cannot be removed well, please wash it with water after separation.
  • Page 19 Before calling for service, review this list. It may save you time and expense. This list includes common occurrences that are not the result of defective workman-ship or materials in this appliance. Problem Solution Wall plug disconnected. Push plug firmly into wall outlet. Air conditioner does not start House fuse blown or circuit breaker tripped.
  • Page 20 Problem Solution Unit removing large quantity of moisture from humid room. This is normal during Water dripping excessively humid days. OUTSIDE when unit is cooling. Remote control not located within range. Place remote control within 20 feet & 180 , Remote Sensing radius of the front of the unit.
  • Page 24 QUESTIONS OR COMMENTS? COUNTRY CALL OR VISIT US ONLINE AT 1-800-10-7267864 [ PLDT - Toll Free ] 1-800-8-7267864 [ Globe - Toll Free ] PHILIPPINES www.samsung.com/ph/support 84222111 [ Landline ] This appliance is led with R-32.

This manual is also suitable for: