5855836-YTG-A-0220
SYSTEM CAPACITY - Single Piece and Modular Air Handlers
AIR HANDLER
UNIT
MODEL
MODEL
YEE42B21S
MVC14DN21
YEE42B21S
MVC16CN21
YEE42B21S
MVC20DN21
YEE48B21S
AE48CX21
YEE48B21S
AE48DBC21
YEE48B21S
AE48DX21
YEE48B21S
AVC48CX21
YEE48B21S
AVC48DX21
YEE48B21S
ME16CN21
YEE48B21S
ME20DN21
YEE48B21S
MVC14DN21
YEE48B21S
MVC16CN21
YEE48B21S
MVC20DN21
YEE60B21S
AE60DX21
YEE60B21S
AVC60DX21
YEE60B21S
ME20DN21
YEE60B21S
MVC20DN21
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ANSI/AHRI Standard 210/240.
1. Cooling MBH based on 80°F entering air temperature, 50% RH (Relative Humidity), and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTUs at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTUs during a normal annual usage period for cooling divided by the total electric power input in watt-hours during the same period.
2. Heating MBH based on AHRI standards of 70°F DB (Dry Bulb) entering indoor air, 72% RH (Relative Humidity) outdoor air with 25 feet of interconnecting piping and no supplemental electric heat operation.
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input during the same period.
COP (Coefficient of Performance) equals Heating MBH output divided by (total KW input x 3.412).
3. CM coils available with a factory installed horizontal drain pan. See price pages for specific model number.
— = Not applicable.
* Notates "Hot Heat Pump" performance. These ratings are not AHRI listed.
MP Modular Air Handlers use Coil Only Ratings.
6
COIL
RATED
3
MODEL
CFM
WIDTH
24.5
CF/CM48D
1350
21.0
CF/CM48C
1275
24.5
CF/CM48D
1300
24.5
1425
24.5
1225
24.5
1225
21.0
1200
24.5
1225
21.0
CF/CM48C
1325
24.5
CF/CM48D
1250
24.5
CF/CM48D
1200
21.0
CF/CM48C
1275
24.5
CF/CM48D
1300
24.5
1675
24.5
1500
24.5
CF/CM64DXA1
1675
24.5
CF/CM64DXA1
1650
1
COOLING
NET MBH
SEER
EER
TOTAL
SENS.
42.5
33.9
14.00
12.75
42.0
32.9
14.00
12.50
42.0
33.1
14.00
12.75
46.5
32.9
14.00
12.00
45.5
29.7
14.00
12.25
45.5
29.7
14.00
12.25
45.5
29.6
14.00
12.00
45.5
29.7
14.00
12.25
46.0
30.7
14.00
12.00
45.5
29.8
14.00
12.25
45.5
29.6
14.00
12.25
45.5
30.0
14.00
12.25
46.0
30.6
14.00
12.25
56.5
39.6
14.00
12.00
55.5
37.3
14.00
12.00
56.5
39.2
14.00
12.00
56.5
39.1
14.00
12.00
HEATING
NET MBH
HSPF
HSPF
Region IV
Region V
47°F OD 17°F OD
37.8
22.2
8.20
6.85
37.6
22.0
8.20
6.90
37.6
22.0
8.20
6.85
45.5
29.8
9.00
8.10
46.0
28.4
9.00
7.55
46.0
28.4
9.00
7.55
46.0
28.6
9.00
7.60
46.0
28.6
9.00
7.55
46.5
28.8
9.00
7.55
46.0
28.6
9.00
7.55
45.5
28.4
9.00
7.55
46.0
28.6
9.00
7.55
46.0
28.6
9.00
7.50
56.0
34.6
9.00
7.90
55.5
35.8
9.00
7.65
55.5
35.8
9.00
7.40
55.5
35.8
9.00
7.40
Johnson Controls Ducted Systems
2
COP
47°F OD 17°F OD
3.40
2.22
3.34
2.18
3.38
2.20
3.58
2.56
3.68
2.56
3.68
2.56
3.60
2.52
3.66
2.54
3.68
2.54
3.68
2.56
3.66
2.56
3.68
2.56
3.72
2.58
3.70
2.60
3.72
2.68
3.84
2.74
3.84
2.74