Download Print this page

Advertisement

Quick Links

Your Water Hardness (ppm)
Midnight Water
Your Water Is Classed As
Average Water Hardness In Your Area
DO I NEED A WATER SOFTENER?
If your water hardness is above 100ppm then you could
benefit from a water softner.
Based on the information provided in your survey and
your water hardness. we have recommended some of
our water softners that would be suitable for you below..
Your Water Softener Recommendations
350
Very Hard Water
310
Softener
Product Manual
Cyan Domestic Water Softener 18L - $590
Example Text
Example Text
Example Text
Cyan Domestic Water Softener 18L - $590
Example Text
Example Text
Example Text
Cyan Domestic Water Softener 18L - $590
Example Text
Example Text
Example Text
Test ID: [XXX]
WATER HARDNESS CLASSIFICATION
BY PARTS PER MILLION
SOFT WATER
MODERATELY SOFT WATER
SLIGHTLY HARD WATER
MODERATELY HARD WATER
HARD WATER
VERY HARD WATER

Advertisement

loading

Summary of Contents for ULTRA SOFT Midnight

  • Page 1 Test ID: [XXX] Your Water Hardness (ppm) Midnight Water WATER HARDNESS CLASSIFICATION Your Water Is Classed As Very Hard Water BY PARTS PER MILLION Average Water Hardness In Your Area Softener SOFT WATER MODERATELY SOFT WATER DO I NEED A WATER SOFTENER?
  • Page 2 Technical Parameters Height: 460mm Width: 260mm Depth: 465mm Transformer Input: 240V / 50 Hz Transformer Output: DC12V/1.5A Suggested Flow Rate: 500 to 1500 l/hour Water Pressure: 1.5 to 4 bar Water Temperature: 5 to 25C Environmental Temperature: 4 to 30C Water Hardness: <400 ppm Capacity At 300ppm Hardness: 600 Litres Per Vessel How Does A Duplex Water Softener Work?
  • Page 3 Parts And Assembly Positioning The Softener Where possible the softener should be placed close to the rising main. Take care to allow hard water take off points for a drinking water facility and /or an outside tap. The distance between the drain and the softener should be as short as possible. Ensure that both the drain and overflow will not freeze or reach a temperature above 40°C.
  • Page 4 Water Pressure Test It is important that a pressure test is carried out. High and low water pressure can result in either damage to or failure of the softener. We recommend the fitting of a pressure limiter should your pressure exceed 4 bar (58 psi). The minimum working pressure for the system is 1.4 bar (20 psi).
  • Page 5: Product Manual

    Waste Pipe Installation Run the waste hose to either an up stand or outside drain, a minimum air gap of 20mm Midnight Water must exist at the end of the drain line. Softened water will have no adverse effect on a septic tank.
  • Page 6 Preparing The Softener To Go Into Service Ensure turbine cable is clipped into outlet pipework. Put approximately 5 litres of water into the brine tank. You may also at this point put a quantity of salt into the tank. Do not allow the salt level in the brine tank to exceed the height of the overflow.
  • Page 7 Changing The Language The display should be in English. If for some reason it is not follow these instructions to change it. Within 6 seconds of switching on the power press and hold both for 5 seconds to enter the advanced menu setup. The top item is language. Press to enter the language choices and press to choose the language...
  • Page 8 Commissioning The Softener With the softener fully plumbed and the valve programmed commissioning can start. Regeneration When the softener is fully functional the regenerations will happen automatically. To initiate an immediate regeneration press the Manual button until the valve motor starts to turn.
  • Page 9 Programming The Valve Should the programming have been lost in transit the following instructions in conjunction with the setting sheet will allow you to re set it. For time, date and hardness settings see the programming settings on page 7. The settings below should not be altered without good reason. Within 6 seconds of switching on the power press and hold both for 5 seconds to enter the advanced menu setup.
  • Page 10: Troubleshooting

    Troubleshooting Following the below as a guide you can find the most common problems that may arise; please consult this section before contacting us as most problems are easily cured by following this information. Problem Possible Cause Solution Softener fails to regenerate A.
  • Page 11 Pressure loss or rust in pipe A. Iron in water supply pipe A. Clean water supply pipe B. Iron mass in the softener B. Clean valve and add resin C. Fouled resin bed clean agent D. Too much iron in raw water C.