Survitec Group EBS CREW User Manual

Emergency breathing system

Advertisement

Quick Links

SURVITEC
EBS CREW
EMERGENCY BREATHING SYSTEM
USER MANUAL
Survitec Part Number# 12727009 -
Emergency Breathing System (EBS CREW)
Survitec Reference Number 25-61-915
Survitec Manual Part Number 12967009
Document #: ZE.01.05.0023 Rev. 2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EBS CREW and is the answer not in the manual?

Questions and answers

Summary of Contents for Survitec Group EBS CREW

  • Page 1 SURVITEC EBS CREW EMERGENCY BREATHING SYSTEM USER MANUAL Survitec Part Number# 12727009 - Emergency Breathing System (EBS CREW) Survitec Reference Number 25-61-915 Survitec Manual Part Number 12967009 Document #: ZE.01.05.0023 Rev. 2...
  • Page 2: Table Of Contents

    CE INFORMATION .......................... 3 WARNINGS, CAUTIONS AND NOTES ....................4 INTRODUCTION ..........................5 THE CYLINDER ..........................5 THE EBS CREW FIRST STAGE ......................7 THE EBS CREW SECOND STAGE......................8 FILLING THE CYLINDER ........................ .9 CARE AND MAINTENANCE ......................11 REPAIRS AND SERVICE .......................12...
  • Page 3: Copyright/Trademark Notices

    It may not be distributed through the Internet or computer without prior written consent. MANUFACTURER The Emergency Breathing System (EBS CREW) is manufactured by Survitec Group SURVITEC EUROPEAN REPRESENTATION Survitec Group; Survival One Ltd, Balmoor Industrial Estate, Grange Road, Peterhead...
  • Page 4: Warnings, Cautions And Notes

    If the unit has been exposed to water ingress or contamination it must be serviced and cleaned by a qualified technician prior to being put back in service. WARNING: Discontinue use of any EBS CREW unit post exposure to extreme heat in excess of 121°C.
  • Page 5: Introduction

    By combining the function of a valve and regulator first stage, the EBS CREW reduces weight, bulk and a failure point. The EBS CREW utilizes a robust piston style first stage that greatly reduces moving parts while still providing good breathing characteristics. Fewer parts also make it easy to service and maintain.
  • Page 6 OVERHEATING CAN RESULT IN SERIOUS INJURY OR DEATH. Cylinder Manufacturer Recommendations: EBS CREW Cylinders have a design life of 15 years and an inspection period of 5 years, as indicated on the cylinder. Cylinders must be subjected to a thorough periodic inspection in accordance with ISO 11623. The period of inspection for this composite cylinder is 5 years for non-toxic gases or 3 years for toxic gases.
  • Page 7: The Ebs Crew First Stage

    The EBS CREW is shipped from the factory with the first stage turned “ON”, ready to use and should always be left in the “ON” position during use. Should the EBS CREW be turned off for servicing, you can turn the gas supply back on.
  • Page 8: The Ebs Crew Second Stage

    EBS CREW USER MANUAL CREW THE EBS SECOND STAGE With the On/Off port turned on, the second stage of the regulator assembly receives breathing gas at an intermediate pressure of approximately 9.7 bar from the first stage and delivers it to you at ambient pressure during inhalation.
  • Page 9: Filling The Cylinder

    Fill Port Cap Fill Adapter (Not Included) 3. Attach the EBS CREW Fill Port to a 6.4 mm Female Quick Disconnect Coupling (Not Included with the EBS CREW system). Begin filling process by turning supply gas on slowly. Filling should take at least 11 minutes. The process to safely fill the cylinder per the recommendations set forth is located on page 5 of this manual.
  • Page 10 2: With the EBS CREW Second Stage in your hand, use your thumb and index finger to push down on the Nose Clip tabs on either side of the Second Stage Body to open the Nose Clip.
  • Page 11: Care And Maintenance

    7: Once safely on the surface, discontinue use of the EBS CREW. DO NOT put the EBS CREW back into service until it has been properly serviced by an authorized Service Technician.
  • Page 12: Repairs And Service

    For units in training, service will be once each or or after every 200 uses, whichever comes first. Your complete EBS CREW assembly must be inspected and serviced by an authorized technician using ONLY Survitec supplied parts and service kits.

This manual is also suitable for:

12727009

Table of Contents