Wiring Diagram - Mitsubishi Electric Mr. Slim PLH Series Technical & Service Manual

Table of Contents

Advertisement

6

WIRING DIAGRAM

PLH-1.6KKHC/PLH-2KKHC/PLH-2.5KKHC
SYMBOL
NAME
R.B
REMOTE CONTROLLER BOARD
SW17<R.B>
ADDRESS SELECTOR
SW18<R.B>
FUNCTION SELECTOR
CN1<R.B>
PROGRAM TIMER CONNECTOR
CN2<R.B>
REMOTE SWITCH CONNECTOR
MV
VANE MOTOR
LS
LIMIT SWITCH
H2
DEW PREVENTION HEATER
RT1
ROOM TEMP. THERMISTOR(0°C/15KΩ , 25°C5.4KΩ )
RT2
INDOOR COIL THERMISTOR(0°C/15KΩ , 25°C5.4KΩ )
T
TRANSFORMER
MF
INNER THERMOSTAT FAN MOTOR
C1
FAN MOTOR CAPACITOR
TB2~6
TERMINAL BLOCK
I.B
INDOOR CONTROLLER BOARD
I.B
MF
MV
1
2 3
C1
2 7
1 6
BLU
1 3 5
1 3
FAN1
CNV
FAN
VANE
F.C
X4
X3
X4
X3
1 3 5
FAN2
ON
OFF
1 2 3 4 5 6
I.B
PLH-1.6,2,2.5KKHC (with heater)
TB2
POWER SUPPLY
N
-(1PHASE)
220-240V
50Hz
NOTES :
1. Since the indoor transformer (T)is connected with 240Vpower. If 220, 230v power is used. change the wiring connection showing fig: W2
fig:W2
230V
When power supply is
220V
2. Since the outdoor side electric wiring may change be sure to check the outdoor unit electric wiring for servicing.
3. Indoor and outdoor connecting wires are made with polarities. make wiring matching terminal numbers.
4. Symbols used in wiring diagram above are. / : Terminal block,
5. Emergency operation
If remote controller or microcomputer fails but there is no other truble,. emergency operation is possible by setting dip switch (SW3<I.B>) on the indoor con-
troller board.
[Check items]
(1)Make sure that no other trouble exists the outdoor unit. Trouble with the outdoor unit prevents emergency operation.
(If any trouble exists the outdoor unit error code "P8"will be displayed on the remote controller and the trouble position will be shown on the outdoor controller
board LED. See electric wiring diagram of the outdoor unit for details.)
(2)Make sure that there is no trouble with the indoor fan.
Emergency operation will be continuous run with the power ON/OFF (ON/OFF with the remote controller is not possible).
[Emergency operation procedure]
(1)Switch the fan connector on the indoor controller board from FAN 1 to FAN 2.
(2)Set the dip switch (SW3<I.B>) on the indoor controller board to 1 on and 2 off for cooling and 1 - 2 on for heating.
(3)Turn on the outdoor unit side circuit breaker, then the indoor unit side circuit breaker.
(4)During emergency operation indoor fan runs at High speed but auto-vane does not work.
(5)Thermostat will not function. Cold air blows out for defrosting during heating thus do not operate defrosting for a long time.
(6)Emergency cooling should be limited to 10 hours maximum. (the indoor unit heat exchanger may freeze).
(7)After every operation, switch the fan connector to FAN1, and set all dip switches (SW3<I.B>) to OFF.
NOTE: If the drain water lift up mechanism is identified to be defective with the microcomputer doctor during cooling, do not use emergency operation
(it causes drain overflow)
SYMBOL
CN2L<I.B>
CN51<I.B>
FAN2<I.B>
F.C<I.B>
SW1<I.B>
SW2<I.B>
SW3<I.B>
SW5, SW7<I.B> MODEL SELECTOR
SW6<I.B>
SWA<I.B>
SWB<I.B>
SWC<I.B>
ZNR<I.B>
X1<I.B>
GRILL
BRN
H2
DP
BLU
1 3
1 3
CND
CND
S.U.M
POWER
1 3
CNT
TRANS
FI
X1
LED1 12V POWER
SW7
SW3 SWC OP
ZNR
X1
1 2 3
1 2
Shorting fig *1
SW2
SW5
SW6
SW1
SWA
3
2
1 2 3 4
1 2 3 4
1 2 3 4 5 6 7 8 9 10
fig: *1
1.6KKHC
Service Ref.
2.5KKHC
2KKHC
ON
ON
SW7
OFF
OFF
1 2 3
1 2 3
88H
H1
FS1
FS2
RED
RED
1
BLU
3
5
BLU
3
240V
YELLOW
230V
ORANGE
220V
RED
NAME
LOSSNAY CONNECTOR
CENTRALLY CONTROL CONNECTOR
EMERGENCY OPERATION CONNECTOR
FAN PHASE CONTROL
MODE SELECTOR
ADDRESS SELECTOR
EMERGENCY OPERATION SWITCH
TWIN, TRIPLE SWITCH
HIGH SEILING, NOISE SAVING SELECTOR
NUMBER OF AIR OUTLETS SELECTOR
OPTION SELECTOR
VARISTOR
DRAIN PUMP/D.HEATER RELAY
T
RED
BRN
AC
AC
14.2V
11.1V
4 3 2 1
CN4T
LED2 5V POWER
TRANS
CN40
REMOCON
POWER
1
2
CN50
3
DRAIN
CN21
4
PIPE
STD
5
CN20
1
INTAKE
SWB
CN51
2
2
HEATER
CNTRALLY
3
3
CN41
CN24
CONTROL
4
4
5
1
2 3
4
DS
HEATER
CN24
1
YLW
3
YLW
88H
1
YLW
26H
2
YLW
: Connector.
SYMBOL
NAME
X3<I.B>
VANE MOTOR RELAY
X4<I.B>
FAN MOTOR RELAY
F1<I.B>
FUSE(6.3A)
LED1<I.B>
DC 12V POWER LED
LED2<I.B>
DC 5V POWER LED
CNP<I.B>
DRAIN PUMP CONNECTOR
CN50<I.B>
DRAIN SENSOR CONNECTOR
DP
DRAIN PUMP
DS
DRAIN SENSOR
H1
HEATER
FS1,2
THERMAL FUSE
26H
HEATER THERMAL SWITCH
88H
HEATER CONNECTOR
CNV<I.B>
VANE MOTOR CONNECTOR
L
POWER SUPPLY
N
~(1 PHASE)
GRN /
YLW
220-240V 50Hz
220V 60Hz
TB2
TRANSMISSION
WIRE S
BRN
3
DC 12V
ORN
2
1
YLW
TB4
1
2
1
CN22
3
2
TO REMOCON
4
CN30
YLW
1
2
1
OUTDDOR
1
ORN
2
2
TB5
BRN
3
1
1
CN23
BRN
2
2
VANE
1
1
2
CN2L
2
3
LOSSNAY
4
R.B.
1
CN2
2
SW18
RT1
RT2
TB4
1 2 3
4 3 2 1
SW17
CN1
1 2 3 4 5
8 7 6 5 4 3 2 1
OUTDOOR
UNIT
3
2
1
TB3
OFF
ON
OFF
ON
15

Advertisement

Table of Contents
loading

Table of Contents