Advertisement

ACC400-402, ACC410-411 - Quick Start Guide

Definition

NO (Normally Open) - This is a contact which remains open (as default) until activated, during the
"active" state the contact provides a closed circuit and starts conducting.
NC (Normally Closed) - Is the opposite of a NO contact. The contact will remain closed (as default)
until activated, during the "active" state the circuit breaks and stops current flow.

Setup Examples

Emergency door releases are used in
access control systems to provide
permanent / semi-permanent
switch to either open or close a
circuit.
This examples shows a "Fail
Secure" and "Fail Safe"
scenario. For a "Fail Safe"
setup, the break glass or
button is activated, power
supply then releases power
from the lock, and if power is
lost then the lock also
releases.
Wire in NO or NC depending
on the access controller used
and also on the required state
of the lock during a "Fail-safe"
or "Fail-secure" scenario.
Document ref: qACC400-411
Door Releases
The ACC400, ACC401 and ACC402s activate the switch when
the glass is broken to open a door in an emergency. Range of
colours for flexibility and spare glasses are available. These low
cost units are supplied with a test key.
The ACC410 and ACC411 are resettable emergency door
releases with protective covers.

User Information

·
There are no user serviceable parts, opening or attempting
to repair the product will void the warranty.
·
Do not install or use the device if the wires connected are
damaged or have been subjected to water ingress.
·
Shut off all power to the access control system before wiring
this device.
·
Maintain a clean and safe environment at all times.
ZapCCTV.com

Emergency Door Releases

Zap is a registered trademark of System Q Ltd
© 2022 System Q Ltd
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ACC400 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Zap ACC400

  • Page 1 ACC400-402, ACC410-411 - Quick Start Guide Door Releases The ACC400, ACC401 and ACC402s activate the switch when the glass is broken to open a door in an emergency. Range of colours for flexibility and spare glasses are available. These low cost units are supplied with a test key.
  • Page 2 Emergency Door Releases Zap is a registered trademark of System Q Ltd Connections - ACC400-402, ACC410-411 For operation with a door access control panel or a magnetic lock, the exit button is wired with NC or NO and COM. Connections - ACC410-411...

This manual is also suitable for:

Acc401Acc402Acc410Acc411

Table of Contents