HORNER XLE 5 Manual

HORNER XLE 5 Manual

12 dc in, 12 dc out, 2 – 14/16-bit analog in (ma/v/tc/mv/rtd), 2 – 12-bit analog out

Advertisement

Quick Links

12 DC In, 12 DC Out, 2 - 14/16-bit Analog In (mA/V/Tc/mV/RTD), 2 - 12-bit Analog Out
Find the user manual via the
on the Horner website.
Part Numbers
Global Part Numbers
XLEe - Model 5 with Ethernet
XLT - Model 5
XLTe - Model 5 with Ethernet
European Part Numbers
XLE - Model 5
XLEe - Model 5 with Ethernet
XLT - Model 5
XLTe - Model 5 with Ethernet
Accessories and Add-Ons
Part #
HE-BAT009
CR2450 Lithium Coin Battery
HE-XCK
Programming Cables
2 channel Analog Output I/O option kit,
HE-XDAC
selectable 0-10V, +/-10V, 4-20mA.
4 channel Analog Output I/O option kit,
HE-XDAC107
selectable 0-10V, +/-10V, 4-20mA.
HE-XKIT
Blank I/O Board
Adapter, RJ45 (8P8C) male to 8-pos-
HE200MJ2TRM
ition terminal strip.
Ferrite core for filtering out electrical
HE-FBD001
noise.
XLE/XLT User Manual - MAN0878
Find the user manual via the
on the Horner website.
XLE/XLEe & XLT/XLTe - Model 5
MAN1116-22-EN_XLET_Mod5
Documentation Search
HE-XE105
HE-XE1E5
HE-XT105
HE-XT1E5
HEXE220C115
HEXE221C115
HEXT240C115
HEXT241C115
Description
Documentation Search

Table of Contents

page
page
Page 1
2
2
2
2
2
3
3
3
4
4
4
5
5
6
6
6
6
6
6
6
6
7
7
7
8
8
9
9
9
9
9
10
10
10
10
10
11
11
11
11
11

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the XLE 5 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for HORNER XLE 5

  • Page 1: Table Of Contents

    Overview of XLE and XLT Power Wiring Find the user manual via the Documentation Search page Model 5 Technical Specifications on the Horner website. Digital DC Input Digital DC Outputs Part Numbers Analog Inputs, High Resolution Global Part Numbers Analog Outputs...
  • Page 2: Xle - Model

    TECHNICAL SPECIFICATIONS General Specifications User Interface Primary Power Range 10-30VDC Transflective LCD Sun- light Display Type Readable 500mA, Class 2 Max. Current 750mA, Class 2 with heater* 128 x 64 pixels (XLEe) Resolution 160 x 128 pixels (XLTe) Required Power 130mA @ 24VDC (Steady State) Color...
  • Page 3: Controller Overview

    CONTROLLER OVERVIEW Overview of XLE and XLT Power Wiring NOTE: The Primary Power Range is 10VDC to 30VDC. Primary Power Port Pins Signal Description Ground Frame Ground Input Power Supply Ground Input Power Supply Voltage DC Input / Frame 1. Function Keys 2.
  • Page 4: Model 5 Technical Specifications

    Wiring: Model 5 Model 5 Technical Specifications Digital DC Outputs Digital DC Input 16 Including 2 Configurable PWM 12 Including 4 Configurable HSC Outputs per Module Inputs per Module Outputs Inputs Commons per Module Commons per Module Output Type Sourcing / 10kΩ Pull-Down Input Voltage Range 12VDC / 24VDC Output Frequency...
  • Page 5: Analog Inputs, High Resolution

    Analog Inputs, High Resolution Number of Channels 0-10VDC; 0-20mA; 4-20mA; Input Ranges (Selectable) 100mV PT100 (-200 to 850˚C); J, K, N, T, E, R, S, B Thermocouples 10VDC: -0.5V to +15V; 20mA: -0.5V to +6V Safe Input Voltage Range RTD / T/C: +/- 24VDC Nominal Resolution 10V, 20mA, 100mV: 14 Bits;...
  • Page 6: Wiring: Inputs And Outputs

    WIRING: INPUTS AND OUTPUTS Analog Inputs Information Jumper Settings for Model 5 Raw input values for channels 1-4 are found in the registers Location of I/O jumpers (JP1 - JP4) and wiring connectors as Integer- type data with a range from 0 – 32000. (J1 -J3) with back cover removed: Analog inputs may be filtered digitally with the Filter Con- stant found in the Cscape Hardware Configuration for Ana-...
  • Page 7: J1 - Positive Logic: Digital Inputs

    J1 - Positive Logic: Digital Inputs J3 Wiring - TC & RTD J2 - Positive Logic: Digital Outputs Wiring Details Solid/Stranded Wire: 12-24 awg (2.5-0.2mm2). Strip Length: 0.28” (7mm). Torque, Terminal Hold-Down Screws: 4.5 – 7 in-lbs (0.50 – 0.78 N-m). Page 7...
  • Page 8: Built-In I/O

    Built-In I/O Analog Input Tranzorb Failure The I/O is mapped into OCS Register space, in three sep- A common cause of Analog Input Tranzorb Failure on Ana- arate areas: Digital/Analog I/O, High-Speed Counter I/O, log Inputs Model 2, 3, 4 & 5: If a 4- 20mA circuit is initially and High-speed Output I/O.
  • Page 9: Communications

    COMMUNICATIONS Serial Communication CAN Communications MJ1 Wiring RS-232 with full handshaking or RS-485 half- duplex RS-485 termination via switches; biasing via soft- ware CAN Pin Assignments MJ1 Pins SIGNAL DESCRIPTION SIGNAL DIRECTION CAN Ground – Black CN_L CAN Data Low – Blue SHLD Shield Ground –...
  • Page 10: Dimensions & Installation

    DIMENSIONS & INSTALLATION Dimensions & Panel Cutout Installation Procedure 1. Carefully locate an appropriate place to mount the XLE/XLT. Be sure to leave enough room at the top of the unit for insertion and removal of the microSD™ card. 2. Carefully cut the host panel per the diagram, cre- ating a 92mm x 92mm +/-0.1 mm opening into which the XLE/XLT may be installed.
  • Page 11: Safety & Maintenance

    This device must accept any interference received, includ- ing interference that may cause undesired operation. Technical Support North America 1 (317) 916-4274 (877) 665-5666 www.hornerautomation.com techsppt@heapg.com Europe +353 (21) 4321-266 www.hornerautomation.eu technical.support@horner-apg.com Page 11...

Table of Contents