SCOTT MILLER PRODUCT USER MANUAL Important Safety Instructions READ ALL INSTRUCTIONS BEFORE USE AND RETAIN INSTRUCTIONS FOR FUTURE REFERENCE. Overview of the package content 1 x Scott Miller SM‐V6000 Machine 1 x Aluminium Tube 1 x Power Adaptor 1 x Motorised Floor Brush 1 x Crevice Tool 1 x Soft Brush 1 x Wall Mount (Hanger) 1 x Wall Screw Important safety Instructions To avoid potentially fatal electric shocks: Do not charge or use the appliance outdoors. Never use the vacuum cleaner if the cable, plug or casing are damaged. To avoid unforeseen circumstances, only use power cables supplied by the manufacturer only/or replace damaged power cables provided by manufacturer only. ...
Page 3
SCOTT MILLER PRODUCT USER MANUAL Do not use the adapter with an extension cable; connect the power adapter directly to a power socket. To avoid the risk of injury: Do not change any accessories while the appliance is switched on. Do not use the vacuum cleaner for sharp objects or glass shards. Never use the vacuum on burning matches, glowing ashes or cigarette butts. Do not use the vacuum cleaner on chemical products, stone dust, gypsum, cement or similar particles. Do not use the vacuum for liquid, water or similar particles. This appliance is not suitable for use with inflammable and explosive substances or chemical and aggressive liquids. Always store the appliance indoors. To prevent accidents, keep the appliance in a dry location when not in use. Under extreme conditions, leaks in the battery cells may occur. In the event that battery fluid comes into contact with skin or eyes, the affected area must be rinsed ...
Page 4
SCOTT MILLER PRODUCT USER MANUAL Operation Instructions Assemble the unit Note: Ensure that the vacuum cleaner is not connected to the charger before assembling the extended tube. 1. Remove the vacuum cleaner, extended tube and floor brush from the box. 2. Insert the extended tube into the suction inlet of handheld vacuum cleaner and you will hear the “click” sound when the extended tube is assembled correctly. Please make sure that the extended tube is inserted correctly before use the vacuum cleaner. 3. Connect the floor brush with the extended tube. Please connect the extended tube with the floor brush and push the vacuum cleaner toward the floor brush firmly. ...
Page 5
SCOTT MILLER PRODUCT USER MANUAL 1. To remove the vacuum cleaner from the extended tube, push the extended tube release button to pull out the extended tube from the vacuum cleaner. Grasp the handle of vacuum cleaner and pull the extended tube outwards. 2. You can use the handheld vacuum cleaner directly. If you need to reassemble the unit, please refer the instructions in “assemble the unit”. Using the vacuum cleaner Note: Please remove the charger before using the vacuum cleaner. If the vacuum cleaner is in charging or low battery status, the vacuum cleaner and floor brush will not work properly. 1. The vacuum cleaner can be independently, with crevice nozzle or other connection converter enabled brushes. ...
Page 6
SCOTT MILLER PRODUCT USER MANUAL Removing the dust container & HEPA filter Note: To ensure the optimum performance of the vacuum cleaner, empty the dust container and clean the HEPA filter frequently. 1. Remove the vacuum cleaner from the accessories. Press down on the release button to remove the accessories. 2. Push down on the dust release button. Empty the dust from the dust container. 3. Press down on the release button of dust container to remove the dust container from the vacuum cleaner. 4. Rotate the dust container upper cover towards the “unlock” marking and take out of the upper lid. Then take out of the HEPA filter. 5. Take out the upper dust HEPA filter and the plastic cyclone filter. Then wash them and let it to dry. After drying completely, put back the HEPA filter in the machine. Do not use a washing machine to clean the HEPA filter assembly. Do not use a hair dryer to dry it. Air dry only. 6. Replace the HEPA filter assembly back into the dust container and push the HEPA filter assembly to fix firmly in the dust container. NEVER operate vacuum cleaner without HEPA filter assembly ...
SCOTT MILLER PRODUCT USER MANUAL TROUBLESHOOTING GUIDE PROBLEM POSSIBLE REASON POSSIBLE SOLUTION Vacuum cleaner does Battery discharged. Charge unit. not work Dead battery (battery won’t hold Call customer service or dispose of unit. charge). Wipe and clean dirt from connector. Connector between the unit and Check fuse or breaker, replace the charger are dirty. fuse/reset breaker. No power in electrical outlet Unplug charger. supplying transformer. Activate the system with the charger. Charger is plugged in. System is cut off. Power floor brush Rolling brush is blocked with Remove debris from rolling brush. If does not work debris or string etc. there is string or thread wrapped cut Belt is broken. gently with scissors. Vacuum cleaner is not connected Call customer service for assistance. properly. Connect the vacuum cleaner properly. Vacuum cleaner Dust container is full. 1. Empty dust container ...
Page 8
SCOTT MILLER PRODUCT USER MANUAL Important Make sure that dust filter has completely air dried before replacing back in the vacuum cleaner. Warning Please remove the floor brush from the unit before cleaning it. WARNING: Correct Disposal of this product This marking indicates that this product should not be disposed with other household wastes throughout the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable ...
Need help?
Do you have a question about the SM-V6000 and is the answer not in the manual?
Questions and answers