Working Cycle
P12
Overheat Degree in Smart/
Powerful Mode
P13
Exhaust Gas Temp. of
Electronic Expansion Valve
P14
Electronic Expansion Valve's
Steps during Defrosting
(Set Value*10=Actual Steps)
P15
Electronic Expansion Valve's
Min. Steps (Set Value*10=Actual Steps)
P16
Electronic Expansion Valve's
Working Mode
P17
Manual Steps of
Electronic Expansion Valve
(Set Value*10=Actual Steps)
P18
Overheat Degree in Cooling
Mode
P19
Reserved
P20
Electronic Expansion Valve's
Working Mode When Cooling
P21
Water Pump's Working Mode
When Target Temperature Reached
P22
Fan's Working Mode
P23
Fan's Manual Control Speed
(Set Value*10=Actual Speed)
P24
Ambient Temp. to Start
Auxiliary Electric Heater
P25
Auxiliary Heating
Function in Defrosting Mode
P26
Low temperature protection value
Note: In the above table, the actual value of the electronic expansion valve and the
air speed is 10 times of the parameter displayed value. For example, when the P20
defrost expansion valve opening degree shows 30, the actual value at this time is 300
steps; when P30fan manual rotation speed shows 80, the actual value at this time is
800.
Restore factory settings
In the shutdown state, press and hold the "
seconds to restore the factory settings by wire control. At this time, the buzzer will ring twice
continuously, and all parameter values will change back to the default values.
-5℃~10℃(-9~20℉)
70℃~125℃(158~257℉)
2~45
5~15
0 Manual/1 Auto
2~45
-5℃~10℃(-9~20℉)
/
0=Water Temperature
1=Supercooling
1= Non Stop/2= Stop
3=Intermittent
0=Auto/ 1= Manual
0-99
(Set
Value*10=Actual
Speed)
-20℃~20℃(-4~68℉)
Reserved
-20℃~0℃(-22~32℉)
"+"
"+"
- 21 -
Depends on
Actual Model
95℃(203℉)
Depends on
Actual Model
10
1
35
Depends on
Actual Model
/
0
3
0
80
(Set
Value*10=Actual
Speed)
-20℃(-4℉)
Reserved
-20℃
"+"
"at the same time for 3