Farringdon 12 Wood Stove Operating & Installation Manual PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE UL 1482-2011 CAN/ULC S627-2016 Tested To : BK 655 Rev 10 F15-095 ISSUE DATE : 03/10/2023...
Page 2
Install and operate this stove only in accordance with these instruction Applicable standards: UL 1482-11, CAN/ULC S627-00 This manual describes the installation and operation of the Arada, Farringdon 12 wood heater. This heater meets the 2020 U.S. Environmental Protection Agency’s cored wood emission limits for wood heaters sold after May 15, 2020.
Clearances To Combustible Materials Firebox Liner Panels Final Check List Summer Storage / Non Usage SERVICE & MAINTENANCE Annual Maintenance Cleaning Chimney Sweeping Door Glass Outer Finish Fire Door Rope Replacement Fire Door Glass Replacement 22-23 Service Record Arada Farringdon 12...
WARNING Installation of wood burning stoves must be safe and legal. The Farringdon 12 is designed for installation in the main living area of your home only. If it is not installed correctly, it may cause a house fire. To reduce the risk of fire, the installation instructions must be followed carefully.
When lifting always keep your back straight, Grate Bars bend your legs not your back The Farringdon 12 wood stove is fitted with a Avoid twisting at the waist. It is better to riddling grate system to support the fuel above reposition your feet.
CHECK LIST Inside the appliance body you should find the following: Part Description & Visual Aid (not to scale) Farringdon 12 1. Fuel Retainer 2. Throat Plate 3. Ash Pan 4. Throat Plate Insulation Blanket 5. Instruction Manual Arada Farringdon 12...
Page 7
Inside the appliance you should find the following : Description & Visual Aid (not to scale) Farringdon 12 6. Back Side Liners 7. Front Side Liners 8. Rear Liner 9. Grate Bars 10. Stove Gauntlets 1 Pair 11. Fire Door and grate riddling Handle Arada Farringdon 12...
VENT REQUIREMENTS: 6” (150mm) diameter, single wall,minimum 24 MSG blue steel connector with Listed factory-built Type HT chimney or masonary chimney. CARACTERISTIQUES POUR LES CONDUITS: Raccord en acier bleu minimum 24MSG de 6” (150mm) paroi simple, avec une cheminée en acier fabriqué en usine homologué de type HT ou une cheminée de maçonnerie. Arada Farringdon 12...
ASBESTOS beam is protected by a 13mm (0.5”) sheet of All Arada stoves contain no asbestos in their man- Fire proof board spaced 13mm (0.5”) off the sur- ufacture or construction. If there is a possibility of face with strips of non combustible material.
This must be secured into the flue spigot with ( See Fig. 1 ) 3 screws through the holes provided. The chimney connector must be in good condition and kept clean. Arada Farringdon 12...
Page 12
Note: To avoid chimney problems your fire should not be burnt slowly for longer than 12 hours without a period of fast burning. Inspection is advised on a regular basis and accumulations of more than 3mm removed. Arada Farringdon 12...
Page 13
Factory built chimneys and chimney units must be installed in accordance with the temperature and pressure conditions detailed in the manufacturers instructions. Temperature and pressure limits. Flue gas temperature and static pressure within the chimney must not exceed the limits used during listing tests Arada Farringdon 12...
Page 14
6 inches diameter (15.24cm) PLAN VIEW OF REGISTER PLATE AND CLEARANCES FOR NON INSULATED FLUES Combustible Thick (Plan View Of Steel Register Plate, 1.5mm Register Minimum ) Plate. Minimum 1.5mm Thick Steel. Arada Farringdon 12...
Page 15
Flue liner, rigid or flexible. Minimum 16' high. Connector, rigid or flexible (between flue collar of stove and flue liner) Sample installation into existing chimney. Chimney liner system has to be UL listed to UL 1777 in USA and ULC S635 in Canada. Arada Farringdon 12...
The surface used must be non-combustible and approved to UL 1618 for USA or local codes ( cement, brick, stone, ceramic etc ) Floor protection minimum dimensions D (USA) D (Canada) 198mm 275mm 940mm 960mm 1016mm 8ins. 11ins. 37ins. 38ins. 40ins Arada Farringdon 12...
Page 17
INSTALLATION Stove clearances on floor protection plate The floor protection plate must be of Non-Combustible Material Minimum dimensions listed may be increased C (USA) D (Canada) 203mm 203mm 406mm 458mm 8ins. 8ins. 16ins. 18ins. Arada Farringdon 12...
18ins. 10.5ins. For Alcove Installation The ceiling can be 72ins (1828mm) above the base of the stove or 16ins (406mm) above the top of the stove. Do NOT connect this unit to a chimney serving another appliance. Arada Farringdon 12...
FIREBOX LINER PANELS Throat plate sat correctly on air tube and rear air bar. Note: Insulation blanket not The Arada Farringdon stove uses firebox liner shown for clarity panels to the sides and back. The throat plate sits on top of the perforated air tube at the front and into two slots in the rear air bar.
The following details must be checked and completed in full by the installer at the time of installation. Please answer all questions as fully as possible. Arada stoves cannot be held responsible for the chimney or installation. Arada Farringdon 12...
It is important that your appliance is regularly serviced in accordance with these instructions. DOOR GLASS Note: Only use original Arada components for service replacements, NEVER substitute parts The door glass should remain clear during normal for similar items burning.
The rope gasket can be replaced, using the work bench or similar level surface. universal rope kit (Available from Arada), please follow the instructions below : Unscrew the four screw fixings, securing the ...
Page 23
Use only genuine Arada 5mm Neocrem Ceramic glass as detailed in the parts list shown on page 30. Do not substitute with any other material type or size.
Company Work Carried Out Signature Should you have any questions about your Arada Farringdon stove that have not been covered in this manual please contact your Arada dealer. Please keep all repair receipts safely. Please ensure you have this manual available when an engineer visits so they can complete the service record chart.
Please Note : The burn classification for all GLOVES WHEN REFUELLING YOUR STOVE. appliances in these instructions are classed as intermittent use. DO NOT OPERATE THE STOVE WITH CRACKED OR BROCKEN DOOR GLASS. The Farringdon is NOT designed to burn any type of coal Arada Farringdon 12...
Seek expert advice! Please Note : To avoid chimney problems your appliance should not be burnt at a reduced burn rate without a period of fast burning. Arada Farringdon 12...
When burning wood it is acceptable to maintain an ash bed on top of the grate of approximately 20mm (3/4”) without any un-due effect upon the grate bars. Arada Farringdon 12...
PRIMARY AIR avoided. Air enters the appliance through the control at the bottom of the fire door. The Arada Farringdon has a single control slider sliding left to right. See Fig. 10. & 11. below Note:...
OPERATING INSTRUCTIONS MAIN FIRE DOOR HANDLE A stove mitten is supplied with your Arada Farringdon stove, this is provided for the operation of the fire door handle whilst the stove is in use. Care must be taken when opening and closing the fire door as any surrounding areas of the stove will be very hot.
Throat Plate Insulation AFS3770 Air Slider AFS3405 Throat Plate AFS3775 Comb actuator & clevis lock AFS3795 Tertiary Air Bar AFS3780 Farringdon Feet AFS3700 Air Wash Tube AFS3785 Base Air Cover AFS3710 Grate Bars AFS2375 Pilot Tube AFS3715 Arada Farringdon 12...
The warranty policy applies to wood-burning products identified by the Arada and Aarrow trade names only. Arada Stoves warrants that each stove body will be free of material defect for a period of 10-years from the date of original purchase. If a product is proved to contain a defective component, Arada Stoves will, at its sole discretion authorise repair or replace the defective part at Arada Stoves expense.
Page 32
State to State. If you believe your Arada Stove is defective you should return the defective part/stove at your expense together with the original proof of purchase and stove serial number to the place of purchase. If upon inspection the product is deemed to have a manufacturing defect, an official warranty claim will be processed on your behalf.
A USER QUICK REFERENCE GUIDE FUEL: The Farringdon 12 is suitable for WOOD burning only. Use any untreated well seasoned wood with a moisture content below 20% Never burn:- Any type of coal, charcoal, liquid fuels, garbage plastic of any other household waste.
NOTE : The Farringdon 12 stove has been accessed to meet the requirements of CAN/ULC-S627 and is suitable for installation on a combustible floor, with suitable radiant floor protection in place.
Page 35
267mm 406mm Combustible (18 inch) (43 inch) (10.5 inch) (16 inch) Dimension NOTE : The specification of the chimney as a CAN/ULC-S627 listed or code compliant masonry chimney, must be adhered to during installation of the appliance. Arada Farringdon 12...
Heat Shield (1 off fitted) Operating & Installation Manual Stove Gauntlets (1 Pair) Date of Purchase……………………………….. Name and Address of Supplier……………………………………………………………... ………………………………………………………………………………………………….. ………………………………………………………………………………………………….. Arada Ltd The Fire Works Weycroft Avenue Axminster Devon EX13 5HU United Kingdom Tel: +44(0)1297 632050 www.aradastoves.com...