Page 1
Operating & Installation Manual Farringdon 16 Wood Stove Rev 07 BK685 June 2017 UL1482-11 or ULC S627-00...
Page 2
Install and operate this stove only in accordance with these instruction Applicable standards: UL 1482-11, ULC S627-00 This manual describes the installation and operation of the Arada, Farringdon 16 catalytic equipped wood heater. This heater meets the 2015 U.S. Environmental Protection Agency’s crib wood emission limits for wood heaters sold after May 15, 2015.
Main Fire Door Handle Parts List GUARANTEE ( USA & Canada ONLY ) 34-35 A USER QUICK REFERENCE GUIDE ( ENGLISH AND FRENCH ) 36-37 Additional information on the correct Function of catalyst within this stove FACTORY CHECK LIST Arada Farringdon Stoves...
DO NOT CONNECT THIS STOVE TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE Installation of wood burning stoves must be safe and legal. The Farringdon 16 is designed for installation in main living areas of your home only. If your Farringdon stove is not installed correctly, it may cause a house fire.
When lifting always keep your back straight, Grate Bars bend your legs not your back The Farringdon 16 wood stove is fitted with a Avoid twisting at the waist. It is better to riddling grate system to support the fuel above reposition your feet.
CHECK LIST Inside the appliance body you should find the following: Part Description & Visual Aid (not to scale) Farringdon 16 1. Fuel Retainer 2. Throat Plate 3. Ash Pan 4. Throat Plate Insulation Blanket 5. Instruction Manual Arada Farringdon Stoves...
CHECK LIST Inside the appliance you should find the following : Description & Visual Aid (not to scale) Farringdon 16 6. Back Side Liners 7. Front Side Liners 8. Rear Liner 9. Grate Bars 10. Stove Mitten ( Hot Glove) 11.
DATA LABEL PLATES Farringdon 16 Safety Label A This Stove data label is manufactured from plated mild steel, laser etched with the information detailed below. and is permanently fixed to the top of the stove heat shield CONTACT YOUR LOCAL BUILDING OFFICIAL ABOUT RESTRICTIONS AND INSTALLATION INSPECTION IN YOUR AREA CONTACTER VOTRE RESPONSABLE D’INSTALLATION LOCAL POUR CONNAITRE LES RESTRICTIONS ET INSPECTIONS DES INSTALLATIONS...
Page 9
DATA LABEL PLATES Farringdon 16 Safety Label B This Stove data label is manufactured from plated mild steel, laser etched with the information detailed below. Manufactured by, Fabrique par Arada Ltd Axminster, Devon United Kingdom EX13 5HU Serial #, No. de serie...
Fire proof board spaced 13mm (0.5”) off the sur- ASBESTOS face with strips of non combustible material. Make All Arada stoves contain no asbestos in their man- sure that there is a gap between an ufacture or construction. If there is a possibility of...
24 gauge (0.025 inches 0.64 mm) Factory Made Chimney: This must be secured into the flue spigot with A HT type factory-built chimney approved UL103 3 screws through the holes provided. or ULC 629 with 6 inches diameter (15.24 cm) Arada Farringdon Stoves...
Page 13
(or Inspection is advised on a regular basis and ² Openings) should be increased by 300 mm accumulations of more than 3mm removed. each KW of rated output. Arada Farringdon Stoves...
Page 14
Factory built chimneys and chimney units must be installed in accordance with the tempera- ture and pressure conditions detailed in the manufacturers instructions. Temperature and pressure limits. Flue gas temperature and static pressure within the chimney must not exceed the limits used during listing tests Arada Farringdon Stoves...
Page 15
6 inches diameter (15.24cm) PLAN VIEW OF REGISTER PLATE AND CLEARANCES FOR NON INSULATED FLUES Combustible Thick (Plan View Of Steel Register Plate, 1.5mm Register Minimum ) Plate. Minimum 1.5mm Thick Steel. Arada Farringdon Stoves...
Page 16
(4.8 metres) Connector, rigid or flexible (between flue collar of stove and flue liner) Sample installation into existing chimney. Chimney liner system has to be UL listed to UL 1777 in USA and ULC S635 in Canada. Arada Farringdon Stoves...
Radiated heat caused by stove over firing Spillage of creosote as a result of a chimney fire The surface used must be non-combustible and approved to UL 1618 for USA or local codes ( cement, brick, stone, ceramic etc ) Arada Farringdon Stoves...
Page 18
7 inches (178mm) See diagrams below Without 7 inch (178mm) Step With 7 inch (178mm) Step R VALUE 1.49 Stove side R VALUE 0 Stove side view view 7 inch (178mm) step Arada Farringdon Stoves...
27 inches 14 inches 30 inches 30 inches (760mm) 760 mm 686 mm 356 mm Side Front inches inches inches 478 mm 478 mm 432 mm Do NOT connect this unit to a chimney serving another appliance Arada Farringdon Stoves...
Fig 3 shown for clarity FIREBOX LINER PANELS The Arada Farringdon stove uses firebox liner panels to the sides and back. The throat plate sits on top of the perforated air tube at the front and into two slots in the rear air bar. These parts should come fitted to your stove, if however they are not, proceed as follows to fit them.
INSTALLATION Catalyst Replacement The catalyst in your Farringdon 16 wood stove should be replaced after approximately 12000 hours of burning, or if you notice a darkening of the smoke omitted from your chimney. The catalyst should be replaced every 5 to 6 years irrespective of hours burned.
The following details must be checked and completed in full by the installer at the time of installation. Please answer all questions as fully as possible. Arada stoves cannot be held responsible for the chimney or installation. Arada Farringdon Stoves...
The rope gasket can be replaced, using the The door should be lifted off the hinges so universal rope kit (Available from Arada), that the operation can be carried out on a please follow the instructions below : work bench or similar level surface.
Page 25
Use only genuine Arada 5mm Neocrem Ceramic glass as detailed in the parts list shown on page 30. ( Size 484mm wide x 368mm high ) Do not substitute with any other material type or size.
Company Work Carried Out Signature Should you have any questions about your Arada Farringdon stove that have not been covered in this manual please contact your Arada dealer. Please keep all repair receipts safely. Please ensure you have this manual available when an engineer visits so they can complete the service record chart.
GLOVES WHEN REFUELLING YOUR STOVE. Charcoal can produce high levels of Carbon DO NOT OPERATE THE STOVE WITH CRACKED OR highly toxic Monoxide, a gas. BROKEN DOOR GLASS. The Farringdon 16 is NOT designed to burn any type of coal Arada Farringdon Stoves...
It will give off fumes which are non toxic, but certain persons may find they have Seek expert advice an unpleasant or irritant effect. Ensure that the surrounding area is well ventilated during this time. Arada Farringdon Stoves...
When burning wood it is acceptable to maintain an ash bed on top of the grate of approximately 20mm (3/4”) without any un-due effect upon the grate bars. Arada Farringdon Stoves...
PRIMARY AIR avoided. Air enters the appliance through the control at the bottom of the fire door. The Arada Farringdon has a single control slider sliding left to right. See Fig A & B below Note:...
OPERATING INSTRUCTIONS Catalyst Fig A The Arada Farringdon 16kw stove is fitted with a ceramic catalyst to aid clean burning. The catalyst should be inspected for damage annually and if necessary replaced. The catalyst part number can be found in the parts list on page 33.
OPERATING INSTRUCTIONS MAIN FIRE DOOR HANDLE A stove mitten is supplied with your Arada Farringdon stove, this is provided for the operation of the fire door handle whilst the stove is in use. Care must be taken when opening and closing the fire door as any surrounding areas of the stove will be very hot.
The warranty policy applies to wood-burning products identified by the Arada and Aarrow trade names only. Arada Stoves warrants that each stove body will be free of material defect for a period of 10-years from the date of original purchase. If a product is proved to contain a defective component, Arada Stoves will, at its sole discretion authorise repair or replace the defective part at Arada Stoves expense.
Page 35
State to State. If you believe your Arada Stove is defective you should return the defective part/stove at your expense together with the original proof of purchase and stove serial number to the place of purchase. If upon inspection the product is deemed to have a manufacturing defect, an official warranty claim will be processed on your behalf.
Arada, disponible Combustible: chez votre revendeur agrée. Adresses et détails sont disponibles sur www.aradastoves.com. Le Farringdon 16 est conçu pour ne brûler que du bois. Utiliser du bois non-traité et séché avec un Checking your combustor: pourcentage d’humidité inférieur à 20%.
COATINGS, METAL FOILS, ANY TYPE OF COAL, PLASTIC, OU CONTENANT DES CONSERVATEURS, GARBAGE, SULPHUR OR OIL MAY DAMAGE THE LES EMBALLAGES MÉTALLIQUES, TOUS TYPES DE CATALYST AND REQUIRE IST REPLACEMENT. CHARBON, PLASTIQUE, DÉTRITUS, SOUFRE OU PÉTROLE PEUVENT ENDOMMAGER LE CATALYSEUR ET NÉCESSITER SON REMPLACEMENT. Arada Farringdon Stoves...
Page 38
37 of this manual. Details on checking and replacing can be found on pages 27 and 31 of this manual, pay close attention to the use of the bypass door described in detail on page 31 of this manual. Arada Farringdon Stoves...
Stove Mittens Ceramic Catalyst ( 1 off fitted ) Date of Purchase……………………………….. Name and Address of Supplier……………………………………………………………... ………………………………………………………………………………………………….. ………………………………………………………………………………………………….. Arada Ltd The Fire Works Weycroft Avenue Axminster Devon EX13 5HU United Kingdom Tel: +44(0)1297 35700 Fax: +44(0)1297 35900 www.arada.uk.com BK685...
Need help?
Do you have a question about the Farringdon 16 and is the answer not in the manual?
Questions and answers