cg
, cg
, eg, peg, & lgb user manual
a
i
This section is intended to provide service schedules
and maintenance information for users
Section Contents
Maintenance Overview
Boiler Components
Maintenance Procedures — DAILY
Maintenance Procedures — MONTHLY
Maintenance Procedures — PERIODICALLY
Maintenance Procedures — EVERY 6 MONTHS
Maintenance Procedures — END OF SEASON
Figure 1
Service and maintenance schedule
Beginning of Season
Daily
Monthly
Every 3 Months
Every 6 Months
End of Season
WARNING
!
Follow the service and maintenance procedures given in this manual. Failure to perform service and
maintenance could result in damage to the boiler or system. Failure to follow the directions in this manual
and component literature could result in severe personal injury, death, or substantial property damage.
550-142-301/0123
Section 3
Maintenance
13
14
18
19
21
23
23
Owner Maintenance
(see the following pages for instructions)
Contact your boiler service technician to inspect, service, and start up your boiler
You must have an annual start-up performed by a qualified service technician to
ensure reliable operation of the boiler and system
Check the boiler area
Check air openings
Check the pressure and temperature gauge
Check boiler interior piping
Check venting system
Check air vents
Check boiler relief valve
Check automatic air vents (if used)
Test low water cutoff
Check the boiler gas and water piping
Operate the relief valve
Shut down procedure
Maintenance Overview
Servicing and Maintaining the Boiler
The boiler must be inspected and started at the
beginning of the heating season every year by a
qualified service technician.
The maintenance and service of the boiler listed
in Figure 1 and explained in this manual must be
performed to assure maximum boiler efficiency and
reliability
maintenance
13
1
2
3
4
5
6
7
8