Watts PWPERMKIT Installation, Operation And Maintenance Manual

Watts PWPERMKIT Installation, Operation And Maintenance Manual

Permeate pump

Advertisement

Installation, Operation
and Maintenance Manual
Model PWPERMKIT
PERMEATE PUMP INSTALLATION MANUAL
PURE WATER
Important
Please read the entire manual before proceeding with the
installation and startup. Your failure to follow any attached
instructions or operating parameters may lead to the product's
failure.
Save manual for future reference.

Table of Contents

Package Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Do not use with water that is microbiologically unsafe or
Note:
of unknown quality without adequate disinfection before or after
the system .
IOM-WQ-PWPERMKIT
PWPERMKIT
Pages

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PWPERMKIT and is the answer not in the manual?

Questions and answers

Summary of Contents for Watts PWPERMKIT

  • Page 1: Table Of Contents

    IOM-WQ-PWPERMKIT Installation, Operation and Maintenance Manual Model PWPERMKIT PERMEATE PUMP INSTALLATION MANUAL PURE WATER Important Please read the entire manual before proceeding with the installation and startup. Your failure to follow any attached instructions or operating parameters may lead to the product’s failure.
  • Page 2: Package Contents

    " from end of tube to indicate how far the ing flow . tube should be inserted . The unique Watts Quick-Connect locking Cut the tube square . It is essential that the outside diameter be free of score marks Fitting grips before it seals .
  • Page 3: Permeate Pump Installation With The Standard System

    Permeate Pump Installation Installation Steps with the Standard System 1. Turn off the incoming water to the reverse osmosis unit. Lift the handle on the reverse osmosis drinking water faucet to drain the Parts Needed water from the system and storage tank . (1) Permeate Pump with mounting clip Note: If tank is equipped with a ball valve, close valve to preserve the tank water.
  • Page 4: Permeate Pump Installation With The Manifold System

    Permeate Pump Installation Installation Steps with the Manifold System 1. Turn off the incoming water to the reverse osmosis unit. Lift the handle on the reverse osmosis drinking water faucet to drain the Parts Needed water from the system and storage tank . Note: If tank is equipped with a ball valve, close valve to (1) Permeate Pump with mounting clip preserve the tank water.
  • Page 5 ⁄ " BLACK TUBE DRAIN FLOW RESTRICTOR BLUE BLUE BLUE BLUE GREEN Figure 2: Manifold System after installation of Permeate Pump...
  • Page 6: Permeate Pump Installation With The Kwik-Change Ro

    Permeate Pump Installation Installation Steps with the KWIK-CHANGE RO 1. Turn off the incoming water to the reverse osmosis unit. Lift the handle on the reverse osmosis drinking water faucet to drain the Parts Needed: water from the system and storage tank . Note: If tank is equipped with a ball valve, close valve to pre- ⁄...
  • Page 7 RED TUBE BLUE TUBE RED TUBE BLUE TUBE GREEN TUBE Figure 3: KWIK-CHANGE RO after installation of Permeate Pump...
  • Page 8: Limited Warranty

    LIMITED WARRANTY: Certain Watts Pure Water products come with a limited warranty from Watts Regulator Co. Other products may have no warranty or are covered by the original manufacturer’s warranty only. For specific product warranty information, please visit www.watts.com or the published literature that comes with your product. Any remedies stated in such warranties are exclusive and are the only remedies for breach of warranty.