Indications for Use General Warnings The ARTEK Sport is indicated to aid in the Attention: The potential for cold reduction of pain and swelling injury is greater with extremity post-injury, or surgery, through the application. With foot/ankle or application of cold therapy. This...
• The system set-up requires 3 - 4 lbs. of ice. Each set-up will allow for up to 6 hours of continuous use. • The ARTEK Sport is prescription use only. Do not use without a prescription. • It is the responsibility of the prescribing physician to define the therapy use parameters for each patient, including application site and therapy duration.
The ARTEK Sport Therapy System is a single-patient use cooling system, designed to deliver effective and safe cooling therapy. These user instructions describe the operating and safety procedures for the ARTEK Sport. Read these user Instructions in their entirety, prior to using the ARTEK Sport.
Page 5
ARTEK Sport Keypad The ARTEK Sport device is controlled using a simple, touchpad operation. The touchpad provides the following information and control. Refer to this section during set-up and therapy instruction. Run/Rest Button Indicator Power Time Temperature Time Indicator Button...
9. Once the wrap is full of fluid, press 2. To set up the ARTEK Sport, remove the Run button again to stop water the lid from the tank by rotating flow.
Page 7
Using the ARTEK Sport The ARTEK Sport system delivers cold therapy in durations of 20 and 40 minutes. Refer to your physician’s instructions on which therapy you should use and their instructions on the duration and frequency of use. Apply the wrap to the site of injury. For instructions, see the instructions provide in the wrap kit or see our Universal Wrap instructional videos.
Wrap and Use Application The ARTEK Sport system (device and accessories) carries a 90-day manufacturer warranty. Physical damage not incurred during shipping or use of non-manufacturer provided accessories will void warranty. If a problem with the system presents, refer to the Problem/Resolution table below.
All therapy wraps are for single patient use only. Discard the therapy wraps per local government / city laws on acceptable method of disposal. For further information about your ARTEK Sport, visit us at www.directekusa.com/artek-sport or call us at 866.280.5844...
Technical Information The ARTEK Sport system (device and accessories) comes with a 90-day manufacturer’s warranty. 1.1 Safety Signed Marked on the Equipment 1.2 Technical Specifications ARTEK Sport Part Number 0V9PTSPRT01UNV01 Operating Environment 41F - 80F [5C - 27C] Relative Humidity...
Page 11
Technical Information 1.5 Guidance and Manufacture Declaration - Electromagenic Emissions Electromagnetic Environment - Emission Test Compliance Guidance Complies to Group 1, The equipment uses RF energy only Radiated Emissions EN 55011 Class B for its internal function. Therefore, its RF emissions are very low and Complies to Group 1, Conducted Emissions EN 55011 are not likely to cause interference...
Page 12
Technical Information 1.10 Calibration This equipment is comprised of 1.7 EMC Notice components that are of high accuracy This equipment generates, uses, and and low drift. Under normal operation, can radiate radio frequency energy. If during its useful life, the therapy unit not installed and used in accordance does not require calibration.
Page 13
The information and content within this User Manual is prprietary and confidential to ThermoTek. It may not be reproduced or distributed, in whole or in part, without the prior written permission of ThermoTek. QR Code Ref: Device Set Up and Use: 0P1PATSPTQSU...
Need help?
Do you have a question about the ARTEK SPORT and is the answer not in the manual?
Questions and answers