Installation Guide
Progressive Wall Mixers
Suits Models:
30908, 30948, 33730, 33880, 33887, 35346, 35360
Important requirements:
Must be fitted in
Mains
accordance with
500kpa
AS/NZS 3500
regulator
by qualified
must be
plumber
fitted
Cleaning
Clean only with a soft microfiber or similar cloth and warm clean water. Ensure that
the cloth is clean and free of any grit or chemical. Dry tap off with a soft clean cloth.
Ensure that your tap is not subject to any chemicals, building grit or any type of
abrasive of polish. For care of special finishes please visit our website.
Maintenance
Aerators may need to be flushed from time to time if flow diminishes or stream
pattern deteriorates. For Pegasi & Cascade mixers, use the aerator key provided
to unscrew the aerator, you will notice a "castle" pattern around the edge of the
aerator, the key engages with this enabling you to unscrew the insert easily. For Zeos
models, use the aerator key to unscrew the aerator housing, you will then be able to
pop the insert out the top of the housing. Rinse off the upper face of the insert with
running water and gently brush clean with an old toothbrush to remove any debris
before refitting the aerator.
Faucet Australia Pty Ltd
ABN 83683523321
www.faucetstrommen.com.au
P: +61 3 5450 4236
IG 017
Release Date: 15.02.23
Maximum hot
Water lines
water temp.
must be
municiple water
flushed prior
supply. No bore,
65°C
to connection
dam or hard water
without filtration
31 Tate Drive, Kerang VIC 3579
sales@faucetstrommen.com.au
Only clean
& treatment

Advertisement

loading

Summary of Contents for faucet strommen 30908

  • Page 1 For warranty details see our website: Installation Guide IG 017 https://www.faucetstrommen.com.au/warranty/ Release Date: 15.02.23 Progressive Wall Mixers Suits Models: 30908, 30948, 33730, 33880, 33887, 35346, 35360 Important requirements: Must be fitted in Mains Maximum hot Water lines Only clean accordance with 500kpa water temp.
  • Page 2 90-180 degrees the valve goes from warm to hot. place. 18. Thoroughly check operation and seek assistance from Faucet Strommen should anything Wall sheeting and tiling can be laid close to the shroud and waterproofing membrane not be functioning to expectation.

This manual is also suitable for:

309483373033880338873534635360