TrolMaster HS-1 Manual
Hide thumbs Also See for HS-1:

Advertisement

Overview
Thank you for purchasing the TrolMaster's HS-1 Humidistat Station. It is
specially designed to control dehumidifier with 24V terminal.
With the connection to Hydro-X by four data lines through the four ports on the
back panel, user can use HS-1 to control any dehumidifier with 24V terminal.
Choose your desired humidity setpoint for the Day / Night mode (see Humidity
Settings in Hydro-X's instructions P19-20), the HS-1 will control the dehumidifier
based on the setpoint.
The LCD screen of HS-1 will display the setpoint humidity (upper part) and
current humidity (lower part). When the current measured humidity is higher
than the setpoint, the HS-1 unit will control the dehumidifier to decrease the
humidity to normal setpoint.
Features
Digital Control of Relative Humidity (digital set-point)
LCD Display, Easy Operation
Micro-SD for Firmware Update
Seamless Connectivity with Hydro-X
Control Dehumidifier based on Humidity Setpoint

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HS-1 and is the answer not in the manual?

Questions and answers

Summary of Contents for TrolMaster HS-1

  • Page 1 With the connection to Hydro-X by four data lines through the four ports on the back panel, user can use HS-1 to control any dehumidifier with 24V terminal. Choose your desired humidity setpoint for the Day / Night mode (see Humidity Settings in Hydro-X’s instructions P19-20), the HS-1 will control the dehumidifier...
  • Page 2: Installation

    Installation Pull the 2 tabs outward to release the bracket from the unit, mount the bracket to wall or surface near the dehumidifier. Peel off the outer sheath of all signal cable of a dehumidifier to reveal the copper wire. Then, insert each bare wire into the corresponding terminals on the back panel while pressing the button of the terminal designation at the same time.
  • Page 3 Operation Instructions 1. Connection to Hydro-X When the signal wires are successfully connected to the HS-1 unit, and then connect the HS-1 to the Hydro-X with a RJ12 cable through the DEVICES socket on the bottom of Hydro-X, so now you can see the performance of the...
  • Page 4: Address Assignment

    “Offline” when the HS-1 is connected incorrectly. 2. Address Assignment Press the Addressing button on the HS-1 unit so that the Hydro-X will assign an address such as H1 to HS-1 unit accordingly. The LCD screen of Hydro-X will display “Station H1 has been added”. Please note H1 is not the constant product code, it can be H2 depending on the connection sequence of the dehumidifier device.
  • Page 5: Fan Setting

    You can also check the address code on the Hydro-X as shown below : 3. FAN Setting Press FAN button to select ON or AUTO (toggle to re-select) mode for the fan inside an air-conditioner. AUTO : Fan runs only when the heating or cooling system is on. Auto is the most commonly used setting.
  • Page 7: Firmware Upgrade

    4. Firmware Upgrade Press and hold “Addressing” button while replugging the RJ12 cable, the upgrade process will be done automatically. NOTE : Make sure the file name of firmware upgrade should be named as “hs1_update.hex”. 5. Diagram Appendixes...
  • Page 10: Specifications

    ) In the case of defects of the Humidistat Station, the Humidistat Station will either be replaced or repaired using new or reconditioned products or parts by TrolMaster within three-year warranty from the original date of purchase. For service, return the Humidistat Station in good packaging to our agent with the original sale receipt.
  • Page 11 occur, the current would flow through the ground wire, causing a blown fuse or tripped circuit breaker. 4 . The Humidistat Station should be positioned in a place that it’s easily to be pull out when a fault occurs.

Table of Contents