Firstech, LLC. CM6000 Installation Manual

Alarm and starter

Advertisement

Quick Links

Version 6.07

Advertisement

Table of Contents
loading

Summary of Contents for Firstech, LLC. CM6000

  • Page 1 Version 6.07...
  • Page 2 Alarm and Starter System www.firstechonline.com | www.compustar.com CM6000 Install Guide Table of Contents CM6000 Introduction Kit Contents Installation Basics Remote Programming Routine Placement and Use of Components Common Procedures Wiring Descriptions Option Programming Tables Option Menu Descriptions Special Option Groups 1 & 2...
  • Page 3 Alarm and Starter System www.firstechonline.com | www.compustar.com CM6000 Install Guide Copyright 2011 Firstech, LLC. Page 3...
  • Page 4: Kit Contents

    DAS sensor (FT-DAS) The remote(s) and antenna are modular and are not specific to the control modules. You have the ability to pair almost any Firstech remote(s) and antenna receiver to the CM6000. This includes all 4 and 6 pin antennas.
  • Page 5: Installation Basics

    Alarm and Starter System www.firstechonline.com | www.compustar.com CM6000 Install Guide Installation Basics CM6000 If you are new to installing Firstech Series Remote Starts and/or Alarms, we highly recommended that you thoroughly review this manual to installing your first unit. Key Points to Consider Before Installation: You must code remotes to this system before anything will function.
  • Page 6: Remote Programming Routine

    Alarm and Starter System www.firstechonline.com | www.compustar.com CM6000 Install Guide Remote Programming Routine CM6000 IMPORTANT: Any and all remotes must be coded to the control module prior to performing any and all operations. STEP 1: Activate programming mode by manually turning the vehicle’s key between the Ign On and Off (or the Acc &...
  • Page 7 Alarm and Starter System www.firstechonline.com | www.compustar.com CM6000 Install Guide Placement and Use of Components CM6000 RPS Touch and RPS (Remote Paging Sensor) The RPS is an optional feature. The car call/RPS feature uses a small sensor that is mounted on the inside of your windshield.
  • Page 8: Rps (Remote Paging Sensor) Unlock/Disarm

    Alarm and Starter System www.firstechonline.com | www.compustar.com CM6000 Install Guide Placement and Use of Components CM6000 2 Way LCD remote paging To page a 2 Way LCD remote just tap the ‘Red Circle’ twice. Touch Panel Sensitivity To change touch sensitivity open the driver’s door, hold the button on the back of the RPS Touch until the LEDs go out.
  • Page 9 Alarm and Starter System www.firstechonline.com | www.compustar.com CM6000 Install Guide STEP 5: The LED on the RPS will confirm your first number by flashing BLUE slowly. Once the LED begins to flash rapidly in BLUE, enter your second number by repeating step 4.
  • Page 10 OFF - 1.5 Degree Tilt OFF - 3 Inch Movement Adjusting DAS Shock Sensitivity (CM6000 or CM6300) STEP 1: Turn the ignition to the ‘on’ position. STEP 2: 2 Way remotes-hold buttons 1 and 2 (Lock and Unlock) for 2.5 seconds. You will get two parking light flashes.
  • Page 11: Backup Battery

    Every 2 Way LCD Firstech RF kit includes an optional thermister, which must be plugged into the 2 pin port of the control module for use. This plug is blue on the CM6000. The use of the thermister allows the 2 Way remote to display the vehicle’s interior temperature on the remote LCD (liquid crystal display) as...
  • Page 12 Alarm and Starter System www.firstechonline.com | www.compustar.com CM6000 Install Guide Jumper 3 (Parking Light or Trunk Output) Determines the output type (not polarity) of the green/white wire on connector one (CN1). In the default position it provides a positive (+) parking light output. To change to a positive (+) trunk output move the jumper.
  • Page 13 Alarm and Starter System www.firstechonline.com | www.compustar.com CM6000 Install Guide Alternator Sensing Alternator sensing is an alternative method the remote start can utilize to determine if the engine is running. This is different than the no tach sensing mode so a connection must be made. IMPORTANT: The remotes must be coded prior to setting up alternator sensing.
  • Page 14: Installation Requirements

    Current version starts with 1 flash. Blade Cartridge Slot and Connector CM6000, CM6200, and CM6300 slot gives you the ability to use the Blade-AL and Blade-TB modules from Firstech and ADS. With these modules you can virtually eliminate all wire connections between your control module and bypass module.
  • Page 15: Wiring Descriptions

    Alarm and Starter System www.firstechonline.com | www.compustar.com CM6000 Install Guide The CM6 Series Blade connector has a locking tab. Non-locking tab blade harnesses will work but you MUST TAKE CARE TO NOT PLUG THE HARNESS IN UPSIDE DOWN. Make sure the two notches on the top of the harness face the top (CM and barcode sticker side) of the brain.
  • Page 16 Alarm and Starter System www.firstechonline.com | www.compustar.com CM6000 Install Guide There are two wires coming off of the relay; yellow/black and yellow. To utilize the anti-grind or starter- kill features, the vehicles starter wire must be cut in half, otherwise, cut the relay out of the harness and connect the yellow (Pin 6) directly to the vehicles’...
  • Page 17 Alarm and Starter System www.firstechonline.com | www.compustar.com CM6000 Install Guide Pin 6 Green/White – This is a dual-purpose wire that features selectable functionality thru the parking light/trunk output jumper on the control module. It is either a positive (+) parking light output or positive (+) trunk output.
  • Page 18 Alarm and Starter System www.firstechonline.com | www.compustar.com CM6000 Install Guide Pin 8 Violet/Black - Trunk negative (-) input. This is an optional input that will monitor when the vehicle’s trunk has been opened. The proper wire will provide a (-) trigger while the trunk is open.
  • Page 19 Alarm and Starter System www.firstechonline.com | www.compustar.com CM6000 Install Guide Pin 17 White [POC 8] - Horn honk 250mA negative (-) output. This is an optional output that will pulse the factory horn. The proper wire will show ground (-) while the horn is sounding. To change horn output settings, review Options 3-08 and 3-09.
  • Page 20 Alarm and Starter System www.firstechonline.com | www.compustar.com CM6000 Install Guide Connector 6 (CN6), 4-Pin (RS 232 Data Port) This connector is used for updating control modules via www.firstechonline.com. You must also use this port to flash Blade bypass modules. This port provides simple connectivity of Fortin and iDataLink bypass modules.

Table of Contents