MAX. REFRIGERANT PIPING LENGTH and MAX. HEIGHT DIFFERENCE
Model
MUZ-GS09NA
MUZ-GS09NAH
MUZ-GS09NAHZ
MUY-GS09NA
MUZ-GS12NA
MUZ-GS12NAH
MUZ-GS12NAHZ
MUY-GS12NA
MUZ-GS15NA
MUZ-GS15NAH
MUZ-GS15NAHZ
MUY-GS15NA
MUZ-GS18NA
MUZ-GS18NAH
MUZ-GS18NAHZ
MUY-GS18NA
MUZ-GS24NA
MUZ-GS24NAH
MUZ-GS24NAHZ
MUY-GS24NA
MUZ-GS30NA
MUZ-GS30NAH
MUZ-GS30NA2
MUZ-GS30NAH2
MUY-GS30NA
MUY-GS30NA2
MUZ-GS36NA
MUZ-GS36NAH
MUZ-GS36NA2
MUZ-GS36NAH2
MUY-GS36NA
MUY-GS36NA2
OBH875B
Refrigerant piping: ft.
Max. Height difference
Max. Length
A
65
65
100
100
Indoor
unit
Max. Height
difference
B
B
40
40
50
50
Max. Length
A
Outdoor unit
24
Piping size O.D: in.
Gas
Liquid
3/8
1/2
1/2
5/8
1/4
1/4
1/4
1/4