General Description

The Sentry® ISOLOK® SAL-Q automatic isolatable sampler is designed to obtain samples of liquid and slurry flowing
in a process stream, into which extends a plunger with an annulus for sampling . The ISOLOK SAL-Q sampler has been
configured specifically for use in sampling the process media at the process conditions provided by the user at time of
manufacture .
Each sampler cycle consists of a plunger extension and a plunger retraction . During plunger extension, the volume of
the annulus is filled with a sample of the process stream . The plunger is then retracted into the body of the sampler,
thereby capturing a volume of sample . This sample is then deposited into a sample collection container .
The ISOLOK SAL-Q automatic fixed volume sampler is pneumatically operated . Pressurized air (or other gas) is used to
provide the force to extend and retract the plunger . When in the retracted position, air or other inert gas may be used
to assist the displacement of the sample material from the plunger annulus .
The maximum rated temperature of the ISOLOK SAL-Q sampler is defined by the plunger seals . The plunger seals are
selected based on material compatibility and temperature of the process being sampled . Reference the following
chart:
TX
plunger seal material
T2
Perfluoronated elastomer (FFKM)
Filled PTFE
T3
Fluoroelastomer (FKM)
T4
ECTFE
Ethylene propylene
95 Duro polyurethane
T5
Nitrile
75 Duro polyurethane
T6
UHMW PE
 NOTE:
Figures in this manual may differ from actual purchased equipment . Please refer to the drawings in the appendices of this
document .
Read these instructions completely before proceeding to assemble, install or operate this machine . This machine should
be installed, operated and serviced by qualified individuals . All drive guards and doors must be secured in place when
this machine is being operated . Follow proper local, state and federal regulations for proper installation and operational
requirements .
6
max temperature
550°F (288°C)
500°F (260°C)
400°F (204°C)
325°F (163°C)
250°F (121°C)
230°F (110°C)
225°F (107°C)
212°F (100°C)
200°F (93°C)