OWNER'S GUIDE & INSTALLATION INSTRUCTIONS
Thru-Hull:
1kW with Temperature Sensor
Tilted Element
Models:
B164, SS164
Chirp Models:
B175H, B175HW, B175L, B175M,
SS175H, SS175HW, SS175L, SS175M
Pairs:
SS264N & SS264W
Patent http://www.airmar.com/patent.html
Follow the precautions below for optimal
product performance and to reduce the risk of
property damage, personal injury, and/or death.
WARNING: Always install the two set screws with
marine sealant applied to the threads. This will hold
the hull nut firmly in place. Failure to do so may allow
the hull nut to become loose.
WARNING: Always wear safety glasses, a dust mask,
and ear protection when installing.
WARNING: Immediately check for leaks when the
boat is placed in the water. Do not leave the boat
unchecked for more than three hours. Even a small
leak may allow considerable water to accumulate.
WARNING: Stainless steel housing in a metal hull—
Be sure the washer contacts the hull. Do not tighten
the hull nut with the washer against the isolation
bushing, as the housing will not be firmly installed. If
necessary, sand the isolation bushing until the washer
rests against the hull.
CAUTION: Chirp transducer—Do not install in the
engine compartment or other hot place. The
transducer may fail if it overheats.
CAUTION: Chirp transducer—Always operate the
transducer in water. Operating in air will allow the
transducer to overheat resulting in failure.
CAUTION: The arrow on the top of the transducer
must point toward the keel or centerline of the boat.
This will align the angle of the element inside the
transducer with the deadrise angle of your hull.
CAUTION: Never install a metal transducer on a
vessel with a positive ground system.
CAUTION: Never pull, carry, or hold the transducer by
its cable; this may sever internal connections.
CAUTION: Stainless steel housing in a metal hull—
Stainless steel housing must be isolated from a metal
hull to prevent electrolytic corrosion. Use the isolation
bushing supplied.
CAUTION: Never use solvents. Cleaner, fuel, sealant,
paint, and other products may contain solvents that can
damage plastic parts, especially the transducer's face.
IMPORTANT: For optimal performance, apply marine
sealant to the entire inside surface of the spacer. This
will fill the gap between the spacer and the sidewall of
the transducer preventing vibration.
Transducer
Tilt Angles: 0
, 12
, 20
Record the information found on the cable tag for future reference.
Part No._________________Date___________Frequency________kHz
IMPORTANT: Read the instructions completely before
proceeding with the installation. These instructions supersede
any other instructions in your instrument manual if they differ.
Applications
• Bronze housing recommended for fiberglass or wood hulls.
Never install a bronze housing in an aluminum hull, because
electrolytic corrosion will occur.
• Stainless steel housing compatible with all hull materials.
Recommended for metal hulls to prevent electrolytic corrosion
provided the stainless steel housing is isolated from the metal hull.
Match Tilt Angle of Transducer to Deadrise
Be sure your transducer model matches the deadrise angle of
your hull at the selected mounting location. The tilt angle is printed
on the top of the transducer (Figure 1). To measure the deadrise
angle of your hull at the selected mounting location, use an angle
finder or a digital level (Figure 2).
• 0 transducer for deadrise angles from 0 to 7
• 12 transducer for deadrise angles from 8 to 15
• 20 transducer for deadrise angles from 16 to 24
Figure 1. Top of transducer
Copyright © 2008 - 2012 Airmar Technology Corp.
transom view
Figure 2. Deadrise angle of the hull
Copyright © 2005 Airmar Technology Corp.
tilt angle
B175H
130 - 210 kHz
(0° model shown)
slope of hull
deadrise angle
parallel to waterline

Advertisement

loading
Need help?

Need help?

Do you have a question about the Element B164 and is the answer not in the manual?

Questions and answers

Summary of Contents for Airmar Element B164

  • Page 1 Figure 1. Top of transducer (0° model shown) Stainless steel housing must be isolated from a metal Copyright © 2008 - 2012 Airmar Technology Corp. hull to prevent electrolytic corrosion. Use the isolation bushing supplied. CAUTION: Never use solvents. Cleaner, fuel, sealant,...
  • Page 2 The pigtail outboard and I/O inboard 200kHz 50kHz stepped hull Figure 3. Best location for the transducer Figure 4. Connecting a Pair—single transmission line Copyright © 2007 - 2011 Airmar Technology Corp. Copyright © 2008 Airmar Technology Corp.
  • Page 3 If the cable must be cut and Installing spliced, use Airmar’s splash-proof Junction Box No. 33-035 and 1. From outside the hull, thread the cable through the mounting follow the instructions supplied. Removing the waterproof hole.
  • Page 4 Apply only light pressure to the hole saw after cutting through the inner skin to avoid accidentally cutting the outer skin. 35 Meadowbrook Drive, Milford, New Hampshire 03055-4613, USA • www.airmar.com Copyright © 2007 - 2018 Airmar Technology Corporation. All rights reserved.

This manual is also suitable for:

Element ss164Element b175hElement b175hwElement b175lElement b175mElement ss175h ... Show all