Easy to use
The Transmation CheckMate 200 will check, calibrate
and measure all the DC voltage instruments in your plant.
Three ranges cover most instrumentation voltage signals.
Source voltage
Calibrate recorders, digital indicators, computer inputs or
any other instruments that measure DC volts. Easily set
any value within 0.01 millivolt or volt with the intuitive UP
and DOWN pushbuttons. Separate buttons for each digit
make adjustments fast and easy.
"No-break" calibration
Calibrate any 1 to 5 volt device in a live 4 to 20 milliamp
loop without disconnecting any wires. The CheckMate
200 will automatically source or sink 0 to > 16 milliamps
to clamp the test voltage in all source ranges. Output
impedance is less than 0.3 ohm to let you calibrate
voltage instruments in milliamp loops without removing
the 250 ohm input load resistors.
Recall output settings
The "QUIK-CHEK" pushbuttons provide rapid checking of
any three points in each range. Quik-Chek settings
remain in memory even when the CheckMate 200 is
powered off.
Measure DC voltages
Check controller outputs, batteries or measure the loop
power supply. The CheckMate 200 measures up to
110.00 mV, 11.00 V and 45.0 VDC
Display the present reading, maximum or minimum by
pressing the READ, MAX or MIN pushbuttons to quickly
check how much the loop has varied or the stability of
control.
Voltage Calibrator
CheckMate™ 200
• Calibrate DC voltage instruments
Source 0.00 to 110.00 millivolts
Source 0.00 to 10.25 Volts
• Measure process voltages
Read 0.00 to 110.00 millivolts
Read 0.00 to 10.25 volts
Read 0.0 to 45.0 volts
• Calibrate voltage instruments in
live loops
No need to disconnect current loop or 250
ohm resistor
• Compact and low cost
The CheckMate 200 fits easily into your
pocket and budget.
• Easy to use
One touch to set the output & function
• Accuracy to ±0.025%
Within ±0.02 V or ±0.07 mV
• Long lasting alkaline batteries
Four "AA" Alkaline cells can provide months
of typical use
• Settable "Quik-Chek®"
pushbuttons
Set any HI and LO output in both ranges

Advertisement

loading
Need help?

Need help?

Do you have a question about the CheckMate 200 and is the answer not in the manual?

Questions and answers

Summary of Contents for Transcat CheckMate 200

  • Page 1 Recall output settings The “QUIK-CHEK” pushbuttons provide rapid checking of any three points in each range. Quik-Chek settings remain in memory even when the CheckMate 200 is powered off. Measure DC voltages Check controller outputs, batteries or measure the loop power supply.
  • Page 2 Min/Max Auto-off To read the maximum or minimum input since read CheckMate 200 can be set up to turn itself off HI / MAX mode was entered, simply press the MAX or MIN after 30 minutes of inactivity. The internal timer is pushbutton.
  • Page 3 It is important to remember the CheckMate 200 drives only the device to which it is connected. It has no effect on other devices in the 4 to 20 mA loop. The CheckMate 200 will clamp the selected value in the mV and V Ranges to the maximum sink current of >16 mA.
  • Page 4 Ordering information Part No. CheckMate 200 Voltage Calibrator 23403E Included with each CheckMate 200 are: 1 Pair of test leads with banana plugs and alligator clips Carrying Case PN 1887092 April 2002 Rev A ©2002 Transmation, Inc. Specifications subject to change without notice.

This manual is also suitable for:

23403e