® Contents R&S RT-Z2T Contents 1 Safety information..............4 2 Product description...............6 2.1 Supported Tektronix probes..............6 2.2 Deliveries....................6 2.3 Inspecting the contents................6 2.4 Description of the adapter..............7 3 Putting into operation............9 3.1 Connecting the adapter to the oscilloscope........9 3.2 Connecting the Tektronix probe to the adapter.......
® Safety information R&S RT-Z2T Safety information The product documentation helps you use the product safely and efficiently. Fol- low the instructions provided here and in the following chapters. Intended use The R&S RT-Z2T probe interface adapter is designed for measurements on cir- cuits that are only indirectly connected to the mains or not connected at all.
Page 5
® Safety information R&S RT-Z2T Product integrity The R&S RT-Z2T can withstand a moderate amount of physical and electrical stress. To avoid damage, treat the adapter with care: ● Do not exceed the specified voltage limits. ● Connect the R&S RT-Z2T only to an instrument with Rohde & Schwarz probe interface.
® Product description R&S RT-Z2T Inspecting the contents Product description The R&S RT-Z2T probe interface adapter is designed to connect active Tektronix oscilloscope probes with TekProbe BNC level II interface to oscilloscopes that have a Rohde & Schwarz probe interface. The adapter provides power to the probe.
® Product description R&S RT-Z2T Description of the adapter If the packaging material shows any signs of stress, notify the carrier and your Rohde & Schwarz service center. Keep the package and cushioning material for inspection. ● Inspect the adapter. If there is any damage or defect, or if the R&S RT-Z2T probe interface adapter does not operate properly, notify your Rohde &...
Page 8
® Product description R&S RT-Z2T Description of the adapter Figure 2-2: TekProbe BNC level II interface of the R&S RT-Z2T Manual 1326.4383.02 ─ 04...
® Putting into operation R&S RT-Z2T Connecting the adapter to the oscilloscope Putting into operation Read and observe the instructions in Chapter 1, "Safety information", on page 4 before using the adapter. For your safety, follow the safety instructions delivered with your Rohde &...
® Putting into operation R&S RT-Z2T Connecting the Tektronix probe to the adapter Connect the adapter (1) to the Rohde & Schwarz probe interface of the oscil- loscope (2). The adapter snaps in when connected properly to the port. Figure 3-1: Connecting the R&S RT-Z2T to the Rohde & Schwarz oscilloscope ►...
® Maintenance and service R&S RT-Z2T Contacting customer support Maintenance and service Like all Rohde & Schwarz products, Rohde & Schwarz probes and adapters are of high quality and require only minimum service and repair. However, if service or calibration is needed, contact your Rohde & Schwarz service center. Return a defective product to the Rohde &...
® Maintenance and service R&S RT-Z2T Calibration interval Figure 4-1: QR code to the Rohde & Schwarz support page Returning for servicing Use the original packaging to return your R&S RT-Z2T to your Rohde & Schwarz- service center. A list of all service centers is available on: www.services.rohde-schwarz.com If you cannot use the original packaging, consider the following: 1.
® Maintenance and service R&S RT-Z2T Disposal Storage Protect the product against dust. Ensure that the environmental conditions, e.g. temperature range and climatic load, meet the values specified in the data sheet. Store the product in a shock-resistant case, e.g. in the shipping case. Disposal Rohde &...