Contact ............... 13 Guarantee ..............13 Introduction The Bluetooth Caliper is a tool that is capable of quickly measuring distances between two points and transferring the values to PC via Bluetooth. It speeds up registering the sensor positions for Arborsonic3D and ArborElectro, when the sensors are arranged in an irregular shape.
Trunk shapes registered with caliper in ArborSonic 3D and in ArborElectro software. Package content Display unit with screen, battery and electronics...
Installation Installing the Bluetooth unit of the caliper is very similar to the installation of the Bluetooth unit of the ArborSonic 3D or ArborElectro. Check if Bluetooth is enabled on your PC. (Some computers have an external button to turn Wireless communication on and off.) ...
Page 7
Wait for Caliper to appear in the list and select it. You may have to enter the security PIN code which is 1234. After pairing check the newly installed COM ports by clicking More Bluetooth options (you may have to scroll down), then click COM Ports, and then look for an Outgoing port with Caliper in the name.
The two arms of the caliper need to be inserted into the slots on the main part. The arms and extension arms are color-coded, the right arm has a yellow mark. The Bluetooth caliper has two arms and can have two extension arms. The distance will be measured between...
Page 10
Make sure to keep the screws clean, if needed apply grease. Measurement with the Bluetooth caliper 1. Switch on the caliper by pressing the yellow button, wait for the boot up the finish, this takes approximately 6 seconds.
Page 11
Zero calibration is done when the display shows C110 (for 1100 mm mode) or C200 (for 2000 mm mode when using extension arms). 3. Calibrate end position (only needed for calipers purchased after 2023) by fully opening the caliper and holding the yellow button for 5 seconds.
Page 12
trunk, then press the yellow button. The data should be transmitted immediately, and you should hear the directions for the next sensor pair. Make sure to turn the speakers on and set maximum volume. The distance from the caliper will always be registered in the selected (blue) cell on the geometry page.
Usage Notes Apply short presses for the measurement. Do not push and hold the button during the measurement because it may cause a recalibration at the wrong position. The caliper turns off automatically after 120 seconds of idle time, the display will start to blink before this happens.
Contact In case of any questions feel free to contact us: Email: office@fakopp.com Web: www.fakopp.com Guarantee The guarantee lasts for one year from the arrival of the device for proper use.