1. OVERVIEW

Z-595 iButton KEYS electronic lock is an iButton (Dallas Touch Memory) contact keys reader, a
keyboard and a controller powered by a 9 V (E / PP3) battery. One battery lasts ~20,000
openings or 2.5 years of stand-by mode. This lock has unique enclosure design and installation
method that enable it to be mounted on any metallic or wooden furniture, and connected, all
within 5 minutes.
Locking mechanism of Z-595 is the same size as CAM LOCK mechanical locks, which allows
for Z-595 mounting into the opening already made for a CAM LOCK.
Compact, with support for single-user and multi-user modes, easy in installation, programming
and servicing, this lock is a perfect Access Control solution for various storage places: work
clothes lockers, mailboxes, office furniture, trade equipment.
Z-595 iButton KEYS lock supports two operational modes:
- Single-User Mode typical lock's controller operation: the lock can only be opened by keys or
codes stored in its memory (up to 70).
- Multi-User Mode keys/codes not tied to single lockers, but can close/open any free locker.

2. SPECIFICATIONS

- Keys standards: ....................................................... iButton (DS1990, DS1996);
- Keyboard codes supported: .........................................................................YES;
- Normal keys/codes maximum number: ...........................................................70;
- Master keys maximum number: ........................................................................4;
- Power supply: ......................................................................one 9V PP3 battery;
- NVRAM: ..................................................................................................Present;
- Consumption current: ..................................................≤ 1µA (in standby mode);
- Audio-visual status indication: .......................................buzzer, bicoloured LED;
- Operating temperature: ......................................................................+5...+40°C
- Case materials: ..........................................................silumin, steel, ABS plastic;
- Colour: ........................................................................................................silver;
- Dimensions, mm: ..........................................................................145 x 37 x 27;
- Mounting: .................................................................................... screws and nut.
page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Z-595 iButton KEYS and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Iron logic Z-595 iButton KEYS

  • Page 1 User Manual 1. OVERVIEW Z-595 iButton KEYS electronic lock is an iButton (Dallas Touch Memory) contact keys reader, a keyboard and a controller powered by a 9 V (E / PP3) battery. One battery lasts ~20,000 openings or 2.5 years of stand-by mode. This lock has unique enclosure design and installation method that enable it to be mounted on any metallic or wooden furniture, and connected, all within 5 minutes.
  • Page 2 Z-595 iButton KEYS www.ironlogic.me 3. MOUNTING Alcohol (mm) page 2...
  • Page 3 Z-595 iButton KEYS www.ironlogic.me 4. PROGRAMMING In its factory state, Z-595 is in the Installer mode: its handle turns freely, no Master or Normal keys present in its memory, its keyboard enabled. 4.1. Initial power-up, Master keys creation To create Master keys, the lock must be in its initial power-up state (its memory having no keys stored).
  • Page 4 Z-595 iButton KEYS www.ironlogic.me 4.3. Erase Normal Keys/Codes (2t, 1T) Touch the reader by a Master key shortly twice; two beeps will sound, touch and hold the Master key for 5 s or longer, until a long beep sounds. Take away the Master key.
  • Page 5 Z-595 iButton KEYS www.ironlogic.me 5. SINGLE-USER MODE 5.1. Lock Opening/Closing Touch the probe with a key. - If the key is right, a short beep sounds and the green LED comes up. You now have 6 s to open or close the lock.
  • Page 6 Z-595 iButton KEYS www.ironlogic.me 7. RESET TO FACTORY DEFAULTS - Disconnect the battery - Press and hold the [ 1 ] button on the keypad. - Now connect the battery at the same time. - The red LED starts blinking, in 5 s it changes to solid red, and an intermittent tone will sound.
  • Page 7 Z-595 iButton KEYS www.ironlogic.me 9. FIRMWARE UPDATE The Z-595 iButton KEYS lock can update/replace its firmware from a DS1996 key. The firmware update takes 20 s. Just touch the reader with a DS1996 key containing firmware, and the update will start automatically.
  • Page 8 Z-595 iButton KEYS www.ironlogic.me 14. CONTACTS Authorized representative in the European Union ICONTROL SIA Slokas iela 79A, LV-1007, Riga, Latvia E-mail: info@icontrol.lv Phone: +37124422922 www.ironlogic.me The symbol of crossed-throught waste bin on wheels means that the product must be disposed of at f separate collection point. This also applies to the product and all accessories marked with this symbol.

Table of Contents