Testing the PAS 280MP MK2 in the Office ........................... 16 Required Tools ................................. 16 Connecting a PAS 280MP MK2 in the Office ........................16 Powering the PAS 280MP MK2 and Mount in the Office ....................20 Configuring the PAS 280MP MK2............................. 21 4.4.1 Changing Monitor Orientation .........................
Page 4
Installing the PAS 280MP MK2 on the Mount ......................... 33 Installing the Pilot Monitor .............................. 34 Installing the Operator Monitor............................34 Connecting a PAS 280MP MK2 and Mount in the Aircraft ....................35 5.8.1 Connecting PAS 280MP MK2 Components ...................... 35 5.8.2...
Page 5
PAS 280MP MK2 Operation Guide Table of Contents iXM-RS150F Achromatic Camera ............................. 51 Page 5 of 51...
PAS 280MP MK2 Operation Guide 1. Introduction 1 Introduction Scope This manual describes how to install and use the PAS 280MP MK2 as follows: • Section 2 - PAS 280MP MK2 Overview • Section 3 - Unboxing the PAS 280MP MK2 •...
2. PAS 280MP MK2 Overview 2 PAS 280MP MK2 Overview The PAS 280MP MK2 is a large format, photogrammetric, large area coverage system, with a central projection resolution of 20,150 x 14,118 pixels using the latest BSI CMOS sensors. The aerial system comprises the camera(s), Phase One iX Controller with an integrated Applanix GNSS, IMU and SOMAG mount.
PAS 280MP MK2 Operation Guide 2. PAS 280MP MK2 Overview 2.1.1 iX Controller The iX Controller is the communication center, and 1 TB data storage for the PAS. Based on Microsoft Windows 10, it is responsible for controlling power and communication for all ancillary systems. The storage solution consists of 2 x 500 GB SATA SSDs. For more information on storage, see Appendix C - Data Storage Management.
Single-Band PAS 280MP MK2 Frame The PAS 280MP MK2 frame enables mounting of the cameras and iX Controller. The PAS 280MP MK2 frame legs allow placing the PAS 280MP MK2 frame on a maintenance bench while maintaining sufficient clearance for the camera lenses.
PAS 280MP MK2 Operation Guide 2. PAS 280MP MK2 Overview 2.1.5 Applanix GNSS/IMU The Applanix GNSS/IMU contains a precision GNSS receiver and inertial sensor components, logging capability, and interfaces for mapping sensors and flight management systems. Data such as geographic position (latitude, longitude and attitude), velocity, acceleration, angular rate, orientation (roll and pitch), ground track and performance metrics are available in real-time and through post-processing.
The antenna is powered by the Applanix AP+ card in the iX Controller via a coaxial cable supplied with the antenna. 2.1.7 Monitor Kit The monitor kit allows full control and flight feedback of the PAS 280MP MK2. The monitor kit consists of the following monitors: • pilot monitor •...
SOMAG GSM 4000 Mount You can install the PAS 280MP MK2 frame into a GSM 4000 mount (76013500) instead of the regular DSM 400 mount. The SOMAG GSM 4000 Mount is a hydraulic gimbal system containing four cylinders and two servo pumps.
The iX Flight Pro is pre-installed in iX Controller. For detailed information on using iX Flight Pro, see the iX Flight Pro Operation Guide provided with your PAS 280MP MK2. Note To process captured images, use iX Process available from Phase One.
Page 14
PAS 280MP MK2 Operation Guide 2. PAS 280MP MK2 Overview Dataflow for the PAS 280MP MK2 Cable Signal/Data From Protocol Description Camera Camera trigger iX Controller Camera Analog I/O iX Flight Pro (in iX Controller) calculates Trigger & MEP discrete...
Verify that all parts were supplied according to the specific packing list for your PAS 280MP MK2. Product Identification To enable support for your PAS 280MP MK2, you must identify and record the model and serial numbers for each of the following components: •...
Make sure you place the PAS 280MP MK2 on a work bench capable of withstanding the PAS 280MP MK2 weight. • The PAS 280MP MK2 does not have to be assembled in the mount for testing. You can place the PAS 280MP MK2 next to the mount.
Page 17
Description Connects to 70364000 Power cable, iX Note Controller/Camera (one for each camera) This cable is pre-connected in the PAS 280MP MK2 frame. 1. iX Controller, AUX2 ports 2. iXM-150, right-LEMO port 73234000 USB cable (one for Note each camera) This cable is pre-connected in the PAS 280MP MK2 frame.
Page 18
PAS 280MP MK2 Operation Guide 4. Testing the PAS 280MP MK2 in the Office Order Description Connects to 1. Operator monitor (power, video, USB ports) 75022000 Power, Video DP, USB harness 2. iX Controller AUX1 ports (power); DP (video); USB ports...
Page 19
PAS 280MP MK2 Operation Guide 4. Testing the PAS 280MP MK2 in the Office System and Power Connections Page 19 of 51...
1. Connect the PAS 280MP MK2 power supply to a mains power outlet in the office. 2. Connect the PAS 280MP MK2 power supply cable LEMO connector to the PAS 280MP MK2 28 VDC port. To connect the mount to a power supply: 1.
PAS 280MP MK2 Operation Guide 4. Testing the PAS 280MP MK2 in the Office 2. Wait 10 seconds. 3. On the iX Controller, push the AUXILIARY circuit breaker and confirm that the green LED comes on. Note • The MAIN circuit breaker provides power to the iX Controller motherboard.
Page 22
PAS 280MP MK2 Operation Guide 4. Testing the PAS 280MP MK2 in the Office To change the orientation of the monitors in Windows: 1. On the desktop, tap and hold for 1 second. 2. Tap Display settings. 3. Tap display 1 (pilot monitor), then in Display orientation, select Portrait (flipped).
Page 23
PAS 280MP MK2 Operation Guide 4. Testing the PAS 280MP MK2 in the Office 4. Tap Keep changes. 5. Tap display 2 (operator monitor), then in Display orientation, select Landscape (flipped). 6. Tap Keep changes. Page 23 of 51...
PAS 280MP MK2 Operation Guide 4. Testing the PAS 280MP MK2 in the Office 4.4.2 Changing the Mouse Pointer Color Usually, the operator controls the mouse. In order for the operator to see the pointer on the pilot display, it needs to be enlarged.
PAS 280MP MK2 Operation Guide 4. Testing the PAS 280MP MK2 in the Office 4.4.3 Configuring Touch Monitors 1. In the Windows search box, type calibrate and tap Calibrate the screen for pen or touch input. 2. On the Display tab, tap Setup.
PAS 280MP MK2 Operation Guide 4. Testing the PAS 280MP MK2 in the Office 4. Tap OK. 5. Test the configuration on each monitor by tapping and dragging. The blue frame created by your finger should appear only on the monitor you are touching.
Page 27
PAS 280MP MK2 Operation Guide 4. Testing the PAS 280MP MK2 in the Office Note If Screen Recorder Pro is already running, tap its icon in the taskbar corner ((if it is not shown, first tap the overflow window arrow).
PAS 280MP MK2 Operation Guide 4. Testing the PAS 280MP MK2 in the Office 5. Tap Record | Stop. 6. Tap minimize. 4.4.7 Configuring iX Flight Pro 1. In iX Flight Pro, configure System Settings and Camera Settings as described in the iX Flight Pro Operation Guide.
Page 29
PAS 280MP MK2 Operation Guide 4. Testing the PAS 280MP MK2 in the Office Transferring these position and angular measurements to the camera entrance pupil (nodal point) location requires accurate determination of the lever arms between the antenna and the camera entrance pupil and between the IMU measurement center and the Mount Rotation Center (MRC).
4. Testing the PAS 280MP MK2 in the Office Disconnecting the PAS 280MP MK2 in the Office When you have completed testing the PAS 280MP MK2 in the office: 1. On the operator monitor, shut down Windows. 2. Set the mount POWER SWITCH to OFF.
This section describes how to install a typical PAS 280MP MK2 in an aircraft. Note • The following aircraft installation procedure assumes the PAS 280MP MK2 was previously assembled and tested in the office as described in Section 4 - Testing the PAS 280MP MK2 in the Office. •...
PAS 280MP MK2 Operation Guide 5. Installing the PAS 280MP MK2 in the Aircraft Securing the Mount to the Interface Plate Note • For complete installation instructions and user care for the DSM 400 or GSM 4000, refer to the respective SOMAG manual.
3 x M8-20 screws, as shown in the following figure: To install the PAS 280MP MK2 on the mount: 1. Carefully lower the PAS 280MP MK2 into the center cavity while making sure that there is enough vertical space between the camera lenses and the aircraft optical glass hatch.
5. Installing the PAS 280MP MK2 in the Aircraft To secure the PAS 280MP MK2 to the mount: 1. Fasten the PAS 280MP MK2 frame to the mount using the four M6*16 screws provided. 2. Secure the screws using a maximum torque of 6 Nm.
Connecting a PAS 280MP MK2 and Mount in the Aircraft 5.8.1 Connecting PAS 280MP MK2 Components Verify that all components are connected as described in section 4.2 - Connecting a PAS 280MP MK2 in the Office. 5.8.2 Powering the PAS 280MP MK2 and Mount in the Aircraft Warning •...
4. On the iX Controller, push the AUXILIARY circuit breaker and confirm that the green LED comes on. PAS 280MP MK2 Installed in Aircraft The following figure shows a PAS 280MP MK2 installed and connected in an aircraft. PAS 280MP MK2 Installed in Aircraft...
PAS 280MP MK2 Operation Guide 6. Recommended Flight Operation Procedure 6 Recommended Flight Operation Procedure 1. Follow the recommended flight operation procedure as described in the iX Flight Pro Operation Guide. Page 37 of 51...
PAS 280MP MK2 Operation Guide 7. Post Flight Operations 7 Post Flight Operations 1. Follow the recommended post flight operations as described in the iX Flight Pro Operation Guide. Page 38 of 51...
PAS 280MP MK2 Operation Guide 8. Disassembling the PAS 280MP MK2 8 Disassembling the PAS 280MP MK2 1. On the operator monitor, shut down Windows. 2. Set the mount POWER SWITCH to OFF. 3. On the iX Controller, pull the MAIN circuit breaker out.
PAS 280MP MK2 Operation Guide 9. Troubleshooting 9 Troubleshooting The following table details how to troubleshoot common PAS 280MP MK2 faults. Troubleshooting PAS 280MP MK2 Faults Fault Probable Cause Solutions Camera not ready. No space on SSD storage. • Change SSD storage.
PAS 280MP MK2 Operation Guide Appendix A. Technical Data Appendix A Technical Data PAS 280MP MK2 Weight A.1.1 Single-Band System The weight of the single-band system components is listed in the following table: Description Weight iXM-RS280 F camera (with dual 90mm lens) 4.7 kg/10.4 lb...
B.1.1 IMU-91 or IMU-82 The following table detail the lever arm values for a PAS 280MP MK2 installed in SOMAG DSM 400 Mount with an IMU-91 or IMU-82. Lever Arms Values for PAS 280MP MK2 with IMU-91/IMU-82 in SOMAG DSM 400 Mount...
B.2.1 IMU-91 or IMU-82 The following table detail the lever arm values for a PAS 280MP MK2 installed in SOMAG GSM 4000 Mount with an IMU-91 or IMU-82. Lever Arms Values for PAS 280MP MK2 with IMU-91/IMU-82 in SOMAG GSM 4000 Mount...
PAS 280MP MK2 Operation Guide Appendix C. Data Storage Management Appendix C Data Storage Management Disk Management The iX Controller storage consists of a built-in frame with a removable carrier containing two SSD drives. The drives store the images captured by cameras connected to the iX Controller.
PAS 280MP MK2 Operation Guide Appendix C. Data Storage Management To lock the carrier in the SSD drive bay frame: Note The SSD carrier key is attached to the left side of the iX Controller. 1. Insert the SSD carrier key into the SSD carrier keylock and turn it 90° clockwise. The yellow and green SSD drive LEDs come on momentarily and the green LED remains on.
PAS 280MP MK2 Operation Guide Appendix C. Data Storage Management 4. Push the SSD carrier eject button once to release the button, and again to eject the carrier from the frame. Press eject button once 5. Gently remove the SSD carrier from the iX Controller.
PAS 280MP MK2 Operation Guide Appendix C. Data Storage Management Replacing SSD Drives The iX Controller is factory provided with two 1 TB SSD drives installed in a removable carrier. You can replace the SSDs as required. To achieve optimal performance, both SSDs should have a high writing speed (>500 MB/S).
Page 48
PAS 280MP MK2 Operation Guide Appendix C. Data Storage Management Page 48 of 51...