Summary of Contents for Anodyne Therapy FREEDOM 300
Page 1
Important Safety Information and Instructions Read Entire Booklet Before Operating...
Page 2
Thank you for choosing the Anodyne Freedom 300 for treating your foot/lower leg pain. Using our Freedom 300 could not be any easier. Simply place the Calf Therapy Pad over your calf and the Foot Therapy Pad under your foot and then hold in place with Anodyne attachment system.
TABLE OF CONTENTS Summary: Warnings and Cautions ............4 Summary: Basic Operating Instructions ..........5 General Warnings and Precautions............ 6-8 Purpose of Device (Indications for Use) ..........8 Components (Device and Parts Description) ........9 Environmental Conditions Affecting Use ........... 9 Set Up Instructions ..................10 Operating Instructions ..............
SUMMARY This summary is not intended to replace the complete user instructions. The entire manual should be read and understood before operating the Freedom 300. Warnings and Cautions This device emits heat and may cause burns. Risk of burns is reduced in the following ways: •...
SUMMARY Basic Operating Instruction Set Up: Plug Power Supply into an electrical outlet and depress the On/Off Switch on the Control Unit to the On position. If the Green Indicator Light turns on the device is operational. Turn the On/Off Switch to the Off position. Put the Calf Treatment Pad over the back of your calf: Place the Calf Treatment pad over the back of your calf with the diode clusters resting on the back of your calf.
Freedom 300 should not be used directly over or near the ® womb during pregnancy or directly over an active cancer lesion. The effects of the Freedom 300 (like other modalities) with these types of conditions are unknown. GENERAL WARNINGS AND PRECAUTIONS WARNING: Use carefully.
Page 7
• Like any other electrical device, do not use the Freedom 300 in water, near water or while wet. Use of the Freedom 300 in these situations could cause electrical shock. • Do not use a portable electric generator as a power source as this may damage the electrical components of your Freedom 300.
Treatment Pads or your affected foot or leg with a clear plastic barrier (clear plastic wrap or clear plastic bag) to keep the Freedom 300 clean. • Do not leave your Freedom 300 unattended around small children or pets. This could lead to serious shock, cuts and or infections. •...
COMPONENTS The Anodyne Freedom 300 includes a Calf Treatment Pad with ® Attachment Straps and a Foot Treatment Pad with an Attachment Sandal, Control Unit and Power Supply. Upper Calf Treatment Pad Attachment Strap Lower Attachment Strap Attachment Sandal On/Off...
300 is portable and does not have to be set up in the same location each time. STEP 5: Plug the Power Supply into an active electrical outlet. Note: If you do not set up the Freedom 300 as directed, it will not function properly but there are no other adverse consequences.
INSTRUCTIONS FOR USE OPERATING YOUR FREEDOM 300 Warning: The Freedom 300 emits heat and may cause burns! If either the Calf Treatment Pad or Foot Treatment Pad feels too hot, immediately remove both Treatment Pads and stop treatment by depressing the On/Off switch on the Control Unit to the OFF position.
Page 12
INSTRUCTIONS FOR USE APPLYING THE CALF TREATMENT PAD (CONTINUED) Step 2b: Hold the short side of the top attachment strap against your shin. Wrap the longer side of the top attachment strap around your leg and over the short side of the attachment strap and press the Velcro end to hold in place.
Page 13
The back of your heel should be positioned at the rounded side of the Foot Treatment Pad. Your Freedom 300 should now look like this on your calf and foot, and you are ready to begin treatment.
Calf. Step 5d: Unplug the Power Supply from the wall outlet and store your Freedom 300 in a safe, dry and cool place away from children and pets until the next use. When putting on or taking off the Freedom 300: •...
1. Cleaning is necessary only if the Attachment Straps become excessively soiled. 2. Unplug the Freedom 300 from the electric outlet. 3. Remove the Attachment Straps from the Treatment Pads by placing one hand on the Strap near the Velcro and gently pulling the Treatment Pad away from the strap.
Freedom 300 from working properly and void product warranty. STORAGE When not in use, store your Freedom 300 in a cool, dry area away from access by either children or pets. Storage in a wet or excessively damp location may cause corrosion of electrical components or wiring that may result in electrical shock or impair the proper function of the device.
6664 to arrange for service. RETURNING A UNIT FOR REPAIR To send a unit to Anodyne Therapy, LLC for repair, you must first call 1-800-521-6664 and obtain a return authorization (RA). The following information must be supplied to Anodyne...
LIMITED WARRANTY nodyne Therapy, LLC (“Manufacturer”) warrants the Anodyne ® Freedom 300 (“The Product”) to the immediate purchaser as follows: Limited Warranty Manufacturer warrants that The Product sold hereunder will be free from defects in material and workmanship for a period of one (1) year from the date of purchase with normal use.
Need help?
Do you have a question about the FREEDOM 300 and is the answer not in the manual?
Questions and answers
I have the Model 300. Can you see any lights when using this?
Yes, the Anodyne Therapy FREEDOM 300 model has an indicator light that turns green when the device is turned on and delivering a treatment cycle.