Summary of Contents for Savaria Track Bridge M92940 Series
Page 1
Savaria OWNER’S MANUAL To Be Retained by Owner After Installation by Authorized Savaria Dealer Part No. 001 Rev. 00...
Page 2
Savaria replacement parts. Regularly scheduled maintenance must be performed on your Track Bridge by an Authorized Savaria Dealer to ensure safety and proper operation of the Track Bridge. Refer to the Maintenance section in this manual. If a serious incident occurs in relation to the device should...
STANDARD NOTATIONS The following notations may be used throughout this manual to emphasize important safety information, mechanical concerns, and other important information. Please review and follow all of these messages. Danger messages indicate an imminently hazardous DANGER situation, which, if not avoided, results in death or serious injury.
Maintenance section in this manual. WARNING Savaria Concord Lifts, Inc. cannot ensure complete safety for a Track Bridge that has exceeded its useful life. Wear may cause failure of a part and lead to a patient fall.
Refer to the nameplate tags for the Maximum Load allowed. • Ensure the Track Bridge is installed only with a Savaria ceiling track system and used only with Savaria ceiling lifts. •...
Battery and Charger Safety WARNING Contact your Authorized Savaria Dealer if you are unsure of any of the safety instructions provided below. • Do NOT expose the battery or charger to water or any other liquid. • To avoid injury, do NOT alter the battery in any way. Stop using the battery if any damage is noted.
3. DESCRIPTION Exterior View The image below shows the Track Bridge uninstalled, viewed from below. The ON/OFF switch brings the Track Bridge into operation and safely terminates operation. Figure 1 ON/OFF switch Note that the Track Bridge will only work with devices equipped with a magnetic block as shown in Figure 2.
Page 9
Figure 2 Magnetic block kit provided with the Track Bridge Magnetic block installed on portable trolley Magnetic block installed on the Fixed Lift. Magnetic block installed on the Bariatric lift. Provided with the Track Bridge Bariatric. Part No. 001300-EN, 14-m02-2023 Track Bridge /Track Bridge Bariatric Owner’s Manual...
Charger (M920001) The Track Bridge is supplied with a battery charger as shown below. The Track Bridge is connected to the constant charging system (CCR system) in the track. The battery charger is external to the track system and it is intended to stay connected to CCR at all times.
Symbols The following chart illustrates the symbols that may be used on the nameplate, the packaging and the device. Symbols on nameplate Indicates the medical device manufacturer. This symbol is accompanied by the address of the manufacturer and the date of manufacture. YYYY: Represents the year MM: Represents the month DD: Represents the day...
Page 13
Caution Refer to instruction manual/booklet Consult instructions for use Type BF protection against electrical shocks Refers to the greatest permissible load that can be MAX.LOAD: applied to the product. Ingress Protection: : Protection level against ingress of solid particles : Protection level against ingress of liquids Unique Device Identification (UDI) symbol required by the FDA Indicates the product is a medical device according...
Page 14
Symbols on box label Indicates the temperature limits to which the medical device can be safely exposed Indicates the range of humidity to which the medical device can be safely exposed Indicates the range of atmospheric pressure to which the medical device can be safely exposed Track Bridge /Track Bridge Bariatric Owner’s Manual Part No.
Page 15
Symbols on device Charge Light. Indicates that the device is on charge or charged Power Light. Indicates the power status Maintenance Light. Indicates that maintenance is recommended on the device When activated will lock Track Bridges sections together When activated will unlock Track Bridges sections Clockwise rotation will lock Track Bridges sections together Counter-clockwise rotation will unlock Track...
4. SPECIFICATIONS WARNING This equipment is not suitable in the presence of flammable anesthetic mixtures with air or oxygen, or with nitrous oxide. Product Product Weight 9.8 kg (21.6 lb) Product Life 10 years Safe Working Load (SWL) - 272 kg (600 lb) Track Bridge Safe Working Load (SWL) - 544 kg (1200 lb)
Page 17
Environmental Conditions: Transport/Storage Temperature -25 °C to 70 °C (-13 °F to 158 °F) Humidity 0 to 93%, non-condensing Atmospheric Pressure 500 hPa to 1060 hPA Controls Control Lift presence detected by magnetic sensor Operating Force < 5 N Compliance IEC 60601-1:2005 A1:2012+A2:2020 (Medical Electrical Equipment) IEC 60601-1-11:2015 (Homecare) ISO 10535:2021...
5. USING THE TRACK BRIDGE Before Transfer • The Track Bridge has built-in stoppers that automatically close when the device is disengaged. Ensure these stoppers are in correct position. • Any track extremities other than the extremities blocked by the Track Bridge shall have end stops securely in place as shown below.
Using the Track Bridge 1 Move the ceiling lift inside the Track Bridge. Figure 5 2 Move the mobile Track Bridge (Primary) in front of the fixed Track Bridge (Secondary). You will hear a beep confirming that the Track Bridge is positioned correctly.
Page 21
3 After less than two seconds, the Track Bridge will automatically become engaged. 4 Move the lift across the fixed Track Bridge (Secondary) and into the track. The Track Bridges will remain locked together until the lift returns and crosses the Track Bridge to go back into the mobile track. Figure 7 Part No.
Page 22
5 To disengage the Track Bridge, move the lift across both Track Bridges for it to automatically disconnect. Figure 8 Figure 9 Track Bridge /Track Bridge Bariatric Owner’s Manual Part No. 001300-EN, 14-m02-2023...
CAUTION Do NOT move the lift by pulling the hand control. The handset may spring return and cause injuries. WARNING NEVER leave a person unattended during a transfer to prevent the person from falling and sustaining possible injuries. Manual Operation (electrical) In the unlikely event of a Track Bridge failure, you can use the bypass buttons to manually operate the Track Bridge.
Manual Operation (mechanical) In the unlikely event of a Track Bridge failure, you can use a 4mm Allen Key to manually operate the Track Bridge. Figure 11 Track Bridge /Track Bridge Bariatric Owner’s Manual Part No. 001300-EN, 14-m02-2023...
Recommended Operator Maintenance Schedule It is recommended to perform the following checks/actions as indicated. If any of the checks fail, contact your Authorized Savaria Dealer for service or replacement of parts. Operator Check/Action...
Recommended Dealer Maintenance Schedule It is recommended for an Authorized Savaria Dealer to perform the checks/actions listed in the Operator Maintenance Schedule as well as those listed in the table below. Dealer Check/Action Frequency Check all inside hardware to ensure it is properly tightened...
WARNING Do NOT open the Track Bridge cover. Only an Authorized Savaria Dealer is qualified to open it. Modifications made to the device by someone other than a qualified technician may cause serious injury.
7. TROUBLESHOOTING WARNING Do NOT open the Track Bridge covers. Only an Authorized Savaria Dealer is qualified to open it. Modifications made to the device by someone other than a qualified technician may cause serious injury. For complementary informations, please refer to Device Controls section.
8. ELECTROMAGNETIC COMPATIBILITY Electromagnetic Compliance The Track Bridge has been tested for compliance with current regulatory standards in regards to EMI (electromagnetic interference). WARNING Use of this equipment adjacent to or stacked with other equipment should be avoided because it could result in improper operation. If such use is necessary, this equipment and the other equipment should be observed to verify that they are operating normally.
Electromagnetic Immunity Guidance and Manufacturer’s Declaration - Electromagnetic Immunity - For All Equipment and Systems The Track Bridge is intended for use in the electromagnetic environment specified below. Immunity test IEC 60601 test Compliance Electromagnetic level level environment - guidance Electrostatic +/-8 kV contact +/-8 kV contact...
Page 31
Electromagnetic Immunity (continued) Guidance and Manufacturer’s Declaration - Electromagnetic Immunity - For All Equipment and Systems The Track Bridge is intended for use in the electromagnetic environment specified below. Immunity test IEC 60601 test Compliance Electromagnetic level level environment - guidance Radiated RF 10 V/m 10 V/m...
Page 32
Electromagnetic Immunity (continued) NOTE 1: At 80 MHz and 800 MHz, the higher frequency applies. NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. (a) Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM broadcast and TV broadcast cannot be predicted theoretically with accuracy.
Page 33
THIS PAGE WAS INTENTIONALLY LEFT BLANK Part No. 001300-EN, 14-m02-2023 Track Bridge /Track Bridge Bariatric Owner’s Manual...
Page 34
THIS PAGE WAS INTENTIONALLY LEFT BLANK Track Bridge /Track Bridge Bariatric Owner’s Manual Part No. 001300-EN, 14-m02-2023...
Page 35
THIS PAGE WAS INTENTIONALLY LEFT BLANK Part No. 001300-EN, 14-m02-2023 Track Bridge /Track Bridge Bariatric Owner’s Manual...
Page 36
Track Bridge Bariatric (M92942x) OWNER’S MANUAL Part No. 001300-EN Copyright2023 Rev. 003 14-m02-2023 Savaria Concord Lifts, Inc. 2 Walker Drive Brampton, Ontario, L6T 5E1, Canada www.savaria.com For service or questions about this product, please contact your installing dealer. DEALER NAME:...
Need help?
Do you have a question about the Track Bridge M92940 Series and is the answer not in the manual?