4-3-12. VCO Adjustment (SSC-DC314/DC318P)

1. Press the STEP FORWARD button of the commander
once, LCD indicator of the commander will disappear
for a few seconds and then mode indicator "C8" will
reappear.
2. Press the CHANGE DATA button to display DATA
"1F".
3. Press the STEP FORWARD button of the commander
once. As a result, the displayed mode will change to "FD".
4. Press the CHANGE DATA button to ensure that the
measured voltage is within the specification.
Subject
: Unnecessary
Measurement point : Relay tool TP6 (VCO CONT)
Equipment
: Digital voltmeter
: DC2.1 ± 0.1 V
Specification
Power supply
: 60 Hz (SSC-DC314 )
frequency
50 Hz (SSC-DC318P)
n
When performing step 2, the picture may be disorder.
If the LCD indicator of commander appears, adjustment is
possible.
However, if the LCD indicator of commander not return as
it disappeared, repeat steps 1 to 4 again.
SSC-DC314/DC318P/DC310P (UC, CE)

4-3-13. Data Write

. SSC-DC314/DC318P
1. Press the STEP FORWARD button of the commander
once. Consequently, both mode and data indicators
displays "FF", that is performed for data writing
preparation.
2. Press the STEP FORWARD Button of the commander
once.
The LCD indicator will turn off for a few seconds,
then turn on.
Make sure that the mode indicator displays "00".
n
If the LCD indicator of commander not return as it disappeared,
or the mode indicator does not display "00", there may be
a defective part in the circuit. Repair it, then repeat these
steps.
In this time, do not press the DATA write (PAUSE) button.
. SSC-DC310P
1. Press the STEP FORWARD button of the commander
once, LCD indicator of the commander will disappear
for a few seconds and then mode indicator "C8" will
reappear.
2. Press the STEP FORWARD button twice. Conse-
quently, mode indicator displays from "FD" to "FF",
that is performed for data writing preparation.
3. Press the STEP FORWARD button of the commander
once.
The LCD indicator will turn off for a few seconds,
then turn on.
Make sure that the mode indicator displays "00".
n
If the LCD indicator of commander not return as it disappeared,
or the mode indicator does not display "00", there may be
a defective part in the circuit. Repair it, then repeat these
steps.
In this time, do not press the DATA write (PAUSE) button.
4-9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Super had ccd ssc-dc310pSuper had ccd ssc-dc318p

Table of Contents