Download Print this page
Fortin Evo One Installation Manual

Fortin Evo One Installation Manual

For honda accord
Hide thumbs Also See for Evo One:

Advertisement

Quick Links

ONE
REGULAR INSTALLATION
INSTALLATION RÉGULIÈRE
VEHICLE
VEHICULES
HONDA
Accord
Push-to-Start
D'UN CONTACT DE CAPOT FONCTIONNEL:
Program remote
starter option for
OEM REMOTE STAND
Programmez l'option
démarreur à distance
pour
TÉLÉCOMMANDE
D'ORIGINE STAND
Program remote
starter option for
HEATED SEATS
Programmez l'option
démarreur à distance
pour
SIÈGES CHAUFFANTS
MANDATORY INSTALL | INSTALLATION OBLIGATOIRE
HOOD STATUS : THE HOOD PIN SWITCH (INCLUDED)
* HOOD
MUST BE INSTALLED IF THE VEHICLE CAN BE
PIN
REMOTE STARTED WITH THE HOOD OPEN, SET FUNCTION A11 TO OFF.
CONTACT
STATUT DE CAPOT : LE CONTACT DE CAPOT (INCLUS), DOIT ÊTRE
DE CAPOT
INSTALLÉ SI LE VÉHICULE PEUT DÉMARRER À DISTANCE, LORSQUE LE
CAPOT EST OUVERT, PROGRAMMEZ LA FONCTION A11 À NON.
1 / 9
Page
Vehicle functions supported in this diagram (functional if equipped) | Fonctions du véhicule
YEARS
ANNÉES
2018-2022
BYPASS FIRMWARE VERSION
VERSION LOGICIELLE CONTOURNEMENT
[
73.
38
HONDA/ACURA MINIMUM
IF THE VEHICLE IS NOT EQUIPPED
WITH FUNCTIONAL HOOD PIN:
SI LE VÉHICULE N'EST PAS ÉQUIPÉ
Program bypass option:
Programmez l'option du contournement:
FUNCTION
FONCTION
R.S.
:
ALONE
38
:
ALONE
FUNCTION
FONCTION
:
39
L'ACTIVATION
:
A11
REV.: 20221212
supportées dans ce diagramme (fonctionnelles si équipé)
To add the firmware version and the options, use the
FLASH LINK UPDATER or FLASH LINK MOBILE tool,
]
A11
OFF
NON
UNIT OPTION
OPTION UNITE
C1
D6
MODE
DESCRIPTION
Enable
Press 3x Lock to remote start with the OEM remote.
2
Activé
Appuyez x3 sur Verrouille de la télécommance d'origine
pour démarrer à distance le véhicule.
MODE
DESCRIPTION
Temperature option : AUX.1 activated at 5
remote started
2
Option de température: AUX.1 s'active à 5
démarrage à distance
Notice: the installation of safety
elements are mandatory. The hood pin
SECURITY STICKER
OFF
and the sticker are essential security
NON
elements and must be installed.
AUTOCOLLANT DE
Notice: l'installation des éléments de
SÉCURITÉ
sécurité est obligatoire. Le contact de
WARNING
capot et l'autocollant de sécurité sont
ATTENTION
des éléments de sécurité essentiels et
Included
doivent absolument être installés.
Inclus
Guide # 72341
ADDENDUM - SUGGESTED WIRING CONFIGURATION
ADDENDA - SCHÉMA DE BRANCHEMENT SUGGÉRÉ
sold separately.
Pour ajouter la version logicielle et les options,
utilisez l'outil FLASH LINK UPDATER
ou FLASH LINK MOBILE, vendu séparément.
Hood trigger (Output Status).
Contact de capot (état de sortie).
DESCRIPTION
OEM Remote status (Lock/Unlock)
monitoring
Suivi des status (Verrouillage/Déverrouil-
lage) de la télécommande d'origine
Push-to-Start
Push-to-Start
C, 5 seconds after
o
C, 5 secondes après le
o
THIS MODULE MUST BE INSTALLED BY A
QUALIFIED TECHNICIAN. A WRONG
CONNECTION CAN CAUSE PERMANENT
DAMAGE TO THE VEHICLE.
CE MODULE DOIT ÊTRE INSTALLÉ PAR
UN TECHNICIEN QUALIFIÉ, TOUTE
ERREUR DANS LES BRANCHEMENTS
PEUT OCCASIONNER DES DOMMAGES
PERMANENTS AU VÉHICULE.

Advertisement

loading
Need help?

Need help?

Do you have a question about the Evo One and is the answer not in the manual?

Questions and answers

Summary of Contents for Fortin Evo One

  • Page 1 1 / 9 REV.: 20221212 Guide # 72341 Page REGULAR INSTALLATION ADDENDUM - SUGGESTED WIRING CONFIGURATION INSTALLATION RÉGULIÈRE ADDENDA - SCHÉMA DE BRANCHEMENT SUGGÉRÉ Vehicle functions supported in this diagram (functional if equipped) | Fonctions du véhicule supportées dans ce diagramme (fonctionnelles si équipé) VEHICLE YEARS VEHICULES...
  • Page 2 This guide may change without notice. See www.fortin.ca for latest version. 2 / 9 Page Ce guide peut faire l’objet de changement sans préavis. Voir www.fortin.ca pour la récente version. DESCRIPTION | DESCRIPTION BCM Brown 66-PINS connector. BCM Blue 66-PINS connector.
  • Page 3 This guide may change without notice. See www.fortin.ca for latest version. 3 / 9 Page Ce guide peut faire l’objet de changement sans préavis. Voir www.fortin.ca pour la récente version. AUTOMATIC TRANSMISSION WIRING CONNECTION | SCHÉMA DE BRANCHEMENT TRANSMISSION AUTOMATIQUE Yellow...
  • Page 4 This guide may change without notice. See www.fortin.ca for latest version. 4 / 9 Page Ce guide peut faire l’objet de changement sans préavis. Voir www.fortin.ca pour la récente version. MANUAL TRANSMISSION WIRING CONNECTION | SCHÉMA DE BRANCHEMENT TRANSMISSION MANUELLE Yellow...
  • Page 5 This guide may change without notice. See www.fortin.ca for latest version. 5 / 9 Page Ce guide peut faire l’objet de changement sans préavis. Voir www.fortin.ca pour la récente version. DESCRIPTION | DESCRIPTION THIS MODULE MUST BE INSTALLED BY A HIGHLY QUALIFIED TECHNICIAN. A WRONG CONNECTION CAN CAUSE PERMANENT DAMAGE TO THE VEHICLE.
  • Page 6 This guide may change without notice. See www.fortin.ca for latest version. 6 / 9 Page Ce guide peut faire l’objet de changement sans préavis. Voir www.fortin.ca pour la récente version. DCRYPTOR PROGRAMMING PROCEDURE | PROCÉDURE DE PROGRAMMATION AVEC DCRYPTOR Parts required (not included) Pièces requises (non incluses)
  • Page 7 7 / 9 Page Ce guide peut faire l’objet de changement sans préavis. Voir www.fortin.ca pour la récente version. KEY BYPASS PROGRAMMING PROCEDURE 2/2 | PROCÉDURE DE PROGRAMMATION CONTOURNEMENT DE CLÉ 2/2 Disconnect all connectors and after the 6-Pin (Main-Harness) or the 4-Pin Data-link connector.
  • Page 8 8 / 9 Page Ce guide peut faire l’objet de changement sans préavis. Voir www.fortin.ca pour la récente version. REMOTE STARTER PROGRAMMING PROCEDURE | PROCÉDURE DE PROGRAMMATION DU DÉMARREUR À DISTANCE REFER TO THE QUICK INSTALL GUIDE INCLUDED WITH THE MODULE FOR THE REMOTE STARTER PROGRAMMING.
  • Page 9 The installation in every case is the sole responsibility of the installer performing the work and FORTIN ELECTRONIC SYSTEMS assumes no liability or responsibility whatsoever resulting from any type of installation, whether performed properly, improperly or any other way.