Download Print this page
Fortin EVO ONE Regular Installation
Fortin EVO ONE Regular Installation

Fortin EVO ONE Regular Installation

Mitsubishi outlander (automatic transmission) 2014-2019
Hide thumbs Also See for EVO ONE:

Advertisement

Quick Links

ONE
REGULAR INSTALLATION
INSTALLATION RÉGULIÈRE
VEHICLE
VEHICULES
MITSUBISHI
Outlander
(Automatic Transmission)
HARDWARE VERSION
VERSION MATÉRIELLE
Program remote
Programmez l'option
démarreur à distance:
starter option for
REMOTE STAND
démarreur à distance pour
TÉLÉCOMMANDE D'ORIGI-
Parts required (Not included)
1X 15 AMP Fuse
MANDATORY INSTALL | INSTALLATION OBLIGATOIRE
HOOD STATUS : THE HOOD PIN SWITCH (INCLUDED)
* HOOD PIN
MUST BE INSTALLED IF THE VEHICLE CAN BE REMOTE
STARTED WITH THE HOOD OPEN.
CONTACT
STATUT DE CAPOT : LE CONTACT DE CAPOT (INCLUS), DOIT
DE CAPOT
ÊTRE INSTALLÉ SI LE VÉHICULE PEUT DÉMARRER À DISTANCE,
LORSQUE LE CAPOT EST OUVERT.
1 / 7
Page
YEARS
ANNÉES
2014-2019
2
MINIMUM
Program bypass option:
Programmez l'option du contournement:
Program bypass option
(If equiped with OEM
Programmez l'option du contournement
(Si équipé d'une alarme
FUNCTION
FONCTION
starter option:
31
Program remote
FUNCTION
FONCTION
R.S. OEM
ALONE:
Programmez l'option
38
NE STAND
ALONE:
REV.: 20190513
Vehicle functions supported in this diagram (functional if equipped) | Fonctions du
véhicule supportées dans ce diagramme (fonctionnelles si équipé)
BYPASS
FLASH LINK UPDATER or FLASH LINK MOBILE tool,
FIRMWARE VERSION
[
]
86.
01
MINIMUM
UNIT OPTION
OPTION UNITE
C1
UNIT OPTION
OPTION UNITE
alarm):
D2
d'origine):
MODE
DESCRIPTION
(+) Parking Lights (E1)
6
(+) Parking Lights (E2)
(+) Feux de stationnement (E1)
(+) Feux de stationnement (E2)
MODE
DESCRIPTION
Enable : Press 3x Lock to remote start with the OEM remote.
2
Activé : Appuyez x3 sur Verrouille de la télécommance d'origine
pour démarrer à distance le véhicule.
Pièce(s) requise(s) (Non incluse(s))
1X Fusible 15 AMP
Notice: the installation of safety
elements are mandatory. The hood pin
SECURITY STICKER
and the sticker are essential security
elements and must be installed.
AUTOCOLLANT DE
Notice: l'installation des éléments de
SÉCURITÉ
sécurité est obligatoire. Le contact de
WARNING
capot et l'autocollant de sécurité sont
ATTENTION
des éléments de sécurité essentiels et
Included
doivent absolument être installés.
Inclus
Guide # 28791
ADDENDUM - SUGGESTED WIRING CONFIGURATION
ADDENDA - SCHÉMA DE BRANCHEMENT SUGGÉRÉ
To add the firmware version and the options, use the
sold separately.
Pour ajouter la version logicielle et les options,
utilisez l'outil FLASH LINK UPDATER
ou FLASH LINK MOBILE, vendu séparément.
DESCRIPTION
OEM Remote status (Lock/Unlock)
monitoring
Suivi des status (Verrouillage/Déverrouil-
lage) de la télécommande d'origine
DESCRIPTION
Unlock before / Lock after (Disarm OEM
alarm)
Déverrouille avant / Verrouille après
(Désarme l'alarme d'origine)
THIS MODULE MUST BE INSTALLED BY A
QUALIFIED TECHNICIAN. A WRONG
CONNECTION CAN CAUSE PERMANENT
DAMAGE TO THE VEHICLE.
CE MODULE DOIT ÊTRE INSTALLÉ PAR
UN TECHNICIEN QUALIFIÉ, TOUTE
ERREUR DANS LES BRANCHEMENTS
PEUT OCCASIONNER DES DOMMAGES
PERMANENTS AU VÉHICULE.

Advertisement

loading
Need help?

Need help?

Do you have a question about the EVO ONE and is the answer not in the manual?

Questions and answers

Summary of Contents for Fortin EVO ONE

  • Page 1 1 / 7 REV.: 20190513 Guide # 28791 Page REGULAR INSTALLATION ADDENDUM - SUGGESTED WIRING CONFIGURATION INSTALLATION RÉGULIÈRE ADDENDA - SCHÉMA DE BRANCHEMENT SUGGÉRÉ Vehicle functions supported in this diagram (functional if equipped) | Fonctions du véhicule supportées dans ce diagramme (fonctionnelles si équipé) VEHICLE YEARS VEHICULES...
  • Page 2 This guide may change without notice. See www.fortin.ca for latest version. 2 / 7 Page Ce guide peut faire l’objet de changement sans préavis. Voir www.fortin.ca pour la récente version. DESCRIPTION | DESCRIPTION Key barrel Ignition harnais Fuse box Connecteur d'ignition au Barillet d'ignition Boîte à...
  • Page 3 This guide may change without notice. See www.fortin.ca for latest version. 3 / 7 Page Ce guide peut faire l’objet de changement sans préavis. Voir www.fortin.ca pour la récente version. AUTOMATIC TRANSMISSION WIRING CONNECTION | SCHÉMA DE BRANCHEMENT TRANSMISSION AUTOMATIQUE Yellow...
  • Page 4 This guide may change without notice. See www.fortin.ca for latest version. 4 / 7 Page Ce guide peut faire l’objet de changement sans préavis. Voir www.fortin.ca pour la récente version. DCRYPTOR PROGRAMMING PROCEDURE | PROCÉDURE DE PROGRAMMATION AVEC DCRYPTOR Parts required (not included) Pièces requises (non incluses)
  • Page 5 5 / 7 Page Ce guide peut faire l’objet de changement sans préavis. Voir www.fortin.ca pour la récente version. KEY BYPASS PROGRAMMING PROCEDURE 2/2 | PROCÉDURE DE PROGRAMMATION CONTOURNEMENT DE CLÉ 2/2 Disconnect all connectors and after the 6-Pin (Main-Harness) or the 4-Pin Data-link connector.
  • Page 6 6 / 7 Page Ce guide peut faire l’objet de changement sans préavis. Voir www.fortin.ca pour la récente version. REMOTE STARTER PROGRAMMING PROCEDURE | PROCÉDURE DE PROGRAMMATION DU DÉMARREUR À DISTANCE REFER TO THE QUICK INSTALL GUIDE INCLUDED WITH THE MODULE FOR THE REMOTE STARTER PROGRAMMING.
  • Page 7 The installation in every case is the sole responsibility of the installer performing the work and FORTIN ELECTRONIC SYSTEMS assumes no liability or responsibility whatsoever resulting from any type of installation, whether performed properly, improperly or any other way.