Page 1
22/06/2022 YAV904X8 Note the guidelines in this document are specific to the YAV904X8 . The other components in the system might not meet the same safety ratings. Refer to the documentation of each component in the system to determine...
ELECTROMAGNETIC COMPATIBILITY GUIDELINES The product YAV904X8 to which this manual relates meet the provisions of the EU Directives 2014/30/CE which declares the compliance of electromagnetic compatibility (EMC) and directive 2014/35/CE of low voltages electronic devices.
DESCRIPTION The YAV904X8 module contents 32 DPST Relays forming four banks of 2-Pole 1 to 8 ports. All bank common pins are connected to a twin contact, which makes it easy to re-configure for the following options: • 4 x (1 to 8) •...
CONNECTOR PINOUT (REAR) X1 Connector (Power and CAN) Pin Number Signal Description Ground connection +24V Board power supply CAN L CAN-Bus Low signal CAN H CAN-Bus High signal X1 pinout description Plug type: • Manufacturer: Weidmuller • Model: BLZF 3.50/04/180...
LED BEHAVIOUR LED Name LED Behaviour Definition of Behaviour STATUS Board is not powered on or power supply is not reaching the microcontroller. Solid green Board is powered on, but firmware of microcontroller is not present or is not running due an error. Blinking green Board is powered on and firmware is running properly.
10. HARDWARE SPECIFICATIONS Operation parameters Property Min. Typ. Max. Units • Control Voltage • Operating current @24VDC and 25ºC • kbps CAN Bus operation speed • degC Ambient operating temperature Operation specifications Switching specifications Property Min. Typ. Max. Units • Rated current •...
11. OPERATION Through the PHI6 Explorer soft panel the user can interface with the YAV904X8 board manually. This tool is a very useful for table-top debugging of test-systems or system maintenance on-site. Activate relays By clicking a relay in the panel, the relay closes and its status in the panel is updated.
To start using the product just remove vacuum bag carefully to avoid damage. To install the YAV904X8 simply insert the module on a VPC receiver, vertical or horizontally, according to the Receiver arrangement. Once it is completely inserted, fix YAV module with two 4-40 UNC screws on each side of connector.