Sun Microsystems XCP2040-TRN Manual
Sun Microsystems XCP2040-TRN Manual

Sun Microsystems XCP2040-TRN Manual

Transition card

Advertisement

Quick Links

XCP2040-TRN I/O
Transition Card Manual
For Netra
CP2040 and Netra CP2140 CompactPCI
Boards
Sun Microsystems, Inc.
4150 Network Circle
Santa Clara, CA 95054 U.S.A.
650-960-1300
Part No. 806-6743-11
October 2002, Revision A
Send comments about this document to: docfeedback@sun.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the XCP2040-TRN and is the answer not in the manual?

Questions and answers

Summary of Contents for Sun Microsystems XCP2040-TRN

  • Page 1 XCP2040-TRN I/O Transition Card Manual For Netra CP2040 and Netra CP2140 CompactPCI ™ Boards Sun Microsystems, Inc. 4150 Network Circle Santa Clara, CA 95054 U.S.A. 650-960-1300 Part No. 806-6743-11 October 2002, Revision A Send comments about this document to: docfeedback@sun.com...
  • Page 2 LOOK GUIs and otherwise comply with Sun’s written license agreements. Use, duplication, or disclosure by the U.S. Government is subject to restrictions set forth in the Sun Microsystems, Inc. license agreements and as provided in DFARS 227.7202-1(a) and 227.7202-3(a) (1995), DFARS 252.227-7013(c)(1)(ii) (Oct. 1998), FAR 12.212(a) (1995), FAR 52.227-19, or FAR 52.227-14 (ALT III), as applicable.
  • Page 3: Table Of Contents

    Contents Features 2 I/O Interfaces 3 PIM Card Support 4 SIP Switch Settings 5 Switch SW1101—SCSI Termination 6 Switch SW1401—I2C Write Protect 7 Switch SW0501—Ethernet Boot Selection 7 Software Support 8 Specifications 8 Mechanical Dimensions 8 Power Requirements 8 Environmental Specifications, Compliance, Reliability, and Availability 9 Determining Part Number, Serial Number, and Revision Number 9 Connectors 10...
  • Page 4 Floppy Header Connector 21 Backplane Interface 22 J3 Connector 22 J4 Connector 24 J5 Connector 25 PIM Card Interface 28 Installing the Transition Card in a CompactPCI Chassis 30 XCP2040-TRN I/O Transition Card Manual for Netra CP2040/CP2140 CompactPCI Boards • October 2002...
  • Page 5 Transition Card, its specifications, connectors, and installation process. Who Should Use This Book The XCP2040-TRN I/O Transition Card Manual for Netra CP2040 and Netra CP2140 CompactPCI Boards is written for computer hardware engineers, system programmers, computer technicians, and others involved in the integration of the Netra CP2040/CP2140 boards.
  • Page 6 See one or more of the following for this information: Solaris Handbook for Sun Peripherals ™ ™ AnswerBook2 online documentation for the Solaris operating environment Other software documentation that you received with your system 6 XCP2040-TRN I/O Transition Card Manual for Netra CP2040/CP2140 CompactPCI Boards • October 2002...
  • Page 7 Typographic Conventions Typeface Meaning Examples The names of commands, files, Edit your.login file. AaBbCc123 and directories; on-screen Use ls -a to list all files. computer output % You have mail. What you type, when contrasted AaBbCc123 with on-screen computer output Password: AaBbCc123 Book titles, new words or terms,...
  • Page 8 You can email your comments to Sun at: docfeedback@sun.com Please include the part number (806-6743-11) of your document in the subject line of your email. 8 XCP2040-TRN I/O Transition Card Manual for Netra CP2040/CP2140 CompactPCI Boards • October 2002...
  • Page 9 Manual for Netra CP2040/CP2140 CompactPCI Boards The XCP2040-TRN I/O Transition Card (806-6743-11) is designed to be used with the Netra CP2040/CP2140 CompactPCI boards and is fully compliant with the CompactPCI Core Specification, Release Note for PICMG 2.0 Revision 3.0 (October 1999, PCI Industrial Computers Manufacturers Group).
  • Page 10: Features

    SMC for temperature Supports A/B cPCI connectors as described in the CompactPCI Core Specification, Release Note for PICMG 2.0 Revision 3.0, "Connectors 2mm Type AB Connector System" section XCP2040-TRN I/O Transition Card Manual for Netra CP2040/CP2140 CompactPCI Boards • October 2002...
  • Page 11: I/O Interfaces

    I/O Interfaces The XCP2040-TRN I/O Transition Card provides additional I/O features (through the J3, J4, and J5 CompactPCI connector interfaces) to the CP2040/CP2140 board. Many I/O functions are provided on the transition card rear panel, and the rest of the I/O functions are provided from headers mounted on the card.
  • Page 12: Pim Card Support

    Typical PIM card J5 connector (not included with XCP-2040-TRN) J4 connector J3 connector PIM A connectors (J0801, J0802) Optional PIM Card Placement on XCP2040-TRN I/O Transition Card FIGURE 2 XCP2040-TRN I/O Transition Card Manual for Netra CP2040/CP2140 CompactPCI Boards • October 2002...
  • Page 13: Sip Switch Settings

    (SIP) switch settings on the FIGURE 3 XCP2040-TRN I/O Transition Card. SW0501 SW1401 SW1101 New switch ID Default SIP Switch Settings on XCP2040-TRN I/O Transition Card FIGURE 3 XCP2040-TRN I/O Transition Card Manual for Netra CP2040/CP2140 CompactPCI Boards...
  • Page 14: Switch Sw1101-Scsi Termination

    SCSI B are terminated at the terminated at the transition card Port B transition card Port B Port A Port A SW1101 Switch Settings (Example) FIGURE 4 XCP2040-TRN I/O Transition Card Manual for Netra CP2040/CP2140 CompactPCI Boards • October 2002...
  • Page 15: Switch Sw1401-I2C Write Protect

    Boot from CP2040/CP2140 Default setting: host board RJ45 port A Boot from transition card RJ45 ports Port A Port A Port B Port B SW0501 Switch Settings (Example) FIGURE 6 XCP2040-TRN I/O Transition Card Manual for Netra CP2040/CP2140 CompactPCI Boards...
  • Page 16: Software Support

    5V/3.3V/12V/-12V (maximum 2.5 W). For more information, see the Netra CP2040 Technical Reference and Installation Manual (P/N 806-4994-xx) or the Netra CP2140 Technical Reference and Installation Manual (P/N 816-4908-xx). XCP2040-TRN I/O Transition Card Manual for Netra CP2040/CP2140 CompactPCI Boards • October 2002...
  • Page 17: Environmental Specifications, Compliance, Reliability, And Availability

    Determining Part Number, Serial Number, and Revision Number The XCP2040-TRN I/O Transition Card part number, serial number, and revision can be found on stickers located on the card labels. For proper identification of the card, please see the list below and .
  • Page 18: Connectors

    XCP2040-TRN I/O Transition Card. Upgrading Backplanes for PICMG Compliance The system that you are installing the XCP2040-TRN I/O Transition Card into must have connectors that meet the PICMG 2.0 Revision 3.0 specification. You can upgrade the backplane connectors by using a shroud removal tool, such as provided by the Erni Companies.
  • Page 19: Transition Card I/O Rear Panel Connectors

    USB A connector Ethernet channel A Ethernet channel B TTY A serial port TTY B serial port Cutout for PIM Connector XCP2040-TRN I/O Transition Card Rear Panel Connectors FIGURE 8 XCP2040-TRN I/O Transition Card Manual for Netra CP2040/CP2140 CompactPCI Boards...
  • Page 20: Usb Ports

    Universal Serial Bus Port A (J1003) Signal Descriptions TABLE 3 Signal USB1VDD (PWR) USB1D-(N_CON) USB1D+ (P_CON) USB1_GND Universal Serial Bus Port B (J1005) Signal Descriptions TABLE 4 Signal USB2VDD (PWR) USB2D-(N_CON) USB2D+ (P_CON) USB2_GND XCP2040-TRN I/O Transition Card Manual for Netra CP2040/CP2140 CompactPCI Boards • October 2002...
  • Page 21: Serial Ports

    Note – The two serial ports require the use of specific adapter cables. Use the Serial Cable Adapter, MDSM-9F to DB9M, (6 inch 9 wires), P/N C-CEL-10110-10. The manufacturer is Computer Cable Makers Inc. and can be ordered directly through them. XCP2040-TRN I/O Transition Card Manual for Netra CP2040/CP2140 CompactPCI Boards...
  • Page 22: Fast Ethernet

    SCSI connectors have a direct wire from CP2040/CP2140 backplane signal. shows the SCSI connector pin locations and shows the signal FIGURE 10 TABLE 7 descriptions for the SCSI connector pins. XCP2040-TRN I/O Transition Card Manual for Netra CP2040/CP2140 CompactPCI Boards • October 2002...
  • Page 23 DGND DGND DGND DGND DGND DGND DGND DGND DGND DGND DGND DGND DGND DB12 DGND DB13 DGND DB14 DGND DB15 DGND DBP1 TermP TermP DGND DGND DB10 DGND DB11 DGND XCP2040-TRN I/O Transition Card Manual for Netra CP2040/CP2140 CompactPCI Boards...
  • Page 24 Parallel (J1004) PIM I/O (J0801) PIM power (J0802) C (J1007) Floppy (J1001) PS2 mouse (J1010) PS2 keyboard (J1009) XCP2040-TRN I/O Transition Card On-Board Connectors and Interfaces FIGURE 11 XCP2040-TRN I/O Transition Card Manual for Netra CP2040/CP2140 CompactPCI Boards • October 2002...
  • Page 25 C bus access header pin locations are shown in . The signal descriptions are listed in TABLE 8 C Bus Access Header Pin Locations FIGURE 12 Bus Access Header (J1007) Signal Descriptions TABLE 8 Signal I2C_BP_J4_SDA I2C_BP_J4_SCL XIR_L I2C_PWR DIAG_L_OC I2C_PWR BP_BKRST_OUT_L BP_BKRST_IN_L XCP2040-TRN I/O Transition Card Manual for Netra CP2040/CP2140 CompactPCI Boards...
  • Page 26 PMC_A_IO35 PMC_A_IO57 PMC_A_IO14 PMC_A_IO36 PMC_A_IO58 PMC_A_IO15 PMC_A_IO37 PMC_A_IO59 PMC_A_IO16 PMC_A_IO38 PMC_A_IO60 PMC_A_IO17 PMC_A_IO39 PMC_A_IO61 PMC_A_IO18 PMC_A_IO40 PMC_A_IO62 PMC_A_IO19 PMC_A_IO41 PMC_A_IO63 PMC_A_IO20 PMC_A_IO42 PMC_A_IO64 PMC_A_IO21 PMC_A_IO43 PMC_A_IO22 PMC_A_IO44 XCP2040-TRN I/O Transition Card Manual for Netra CP2040/CP2140 CompactPCI Boards • October 2002...
  • Page 27 SCSI A port on the rear panel. Only one of these SCSI A connectors should be used at a time to avoid long unterminated stubs on the SCSI chain. for SCSI connector pin locations and for signal descriptions for FIGURE 10 TABLE 7 the internal SCSI connector. XCP2040-TRN I/O Transition Card Manual for Netra CP2040/CP2140 CompactPCI Boards...
  • Page 28 TABLE 11 Pin # Signal Name Pin # Signal Name PAR_STB_F PAR_AFD_F PAR_D0_F PAR_ERR_F PAR_D1_F PAR_INIT_F PAR_D2_F PAR_SLIN_F PAR_D3_F PAR_D4_F PAR_D5_F PAR_D6_F PAR_D7_F PAR_ACK_F PAR_BUSY_F PAR_PE_F PAR_SLCT_F XCP2040-TRN I/O Transition Card Manual for Netra CP2040/CP2140 CompactPCI Boards • October 2002...
  • Page 29 Floppy Connector Signal Descriptions TABLE 12 Pin # Signal Name Pin # Signal Name DGND DENSEL DGND DGND DRATE0_MSEN0 DGND INDEX DGND DGND DGND DGND MTR0 DRATE1_MSEN1 DGND STEP DGND WDATA XCP2040-TRN I/O Transition Card Manual for Netra CP2040/CP2140 CompactPCI Boards...
  • Page 30 The pin locations for the J3 connector are shown in FIGURE 16 J3 Connector Pin Location FIGURE 16 The signal descriptions for the J3 connector are shown in TABLE 13 XCP2040-TRN I/O Transition Card Manual for Netra CP2040/CP2140 CompactPCI Boards • October 2002...
  • Page 31 PMC-59 PMC-60 PMC-61 PMC-62 PMC-63 PMC-64 VI/O BD_SEL_5# HEALTHY_5# PCI_RST_5# BD_SEL_4# HEALTHY_4# PCI_RST_4# BD_SEL_3# HEALTHY_3# PCI_RST_3# BD_SEL_2# HEALTHY_2# PCI_RST_2# PCIB_RST_L PCI_RST_6# BD_SEL_1# HEALTHY_1# PCI_RST_1# EP_5V HEALTHY_6# BD_SEL_0# HEALTHY_0# PCI_RST_0# BD_SEL_6# XCP2040-TRN I/O Transition Card Manual for Netra CP2040/CP2140 CompactPCI Boards...
  • Page 32 MIIA_TXD0 MIIA_TX_EN MIIA_MDC MIIA_RXD0 MIIA_TXD3 MIIA_TXD2 MIIA_TXD1 I2C_INT_L FR/BK_SEL MIIB_COL MIIB_MDIO_L MIIB_TX_ER MIIB_RX_CLK MIIB_RX_DV MIIB_RX_ER MIIB_TX_CLKI MIIB_CRS MIIB_RXD0 MIIB_RXD1 MIIB_RXD2 MIIB_RXD3 MIIB_TXD1 MIIB_TXD0 MIIB_TX_EN MIIB_MDC MIIB_TXD3 MIIB_TXD2 XCP2040-TRN I/O Transition Card Manual for Netra CP2040/CP2140 CompactPCI Boards • October 2002...
  • Page 33 SCD<11>_L SCD<10>_L SCD<9>_L SCD<8>_L RSV-MCU-use RSV-MCU-use +3.3V -12V GPIOI-RSV-MCU-use GND J5 Connector The pin locations for the J5 connector are shown in FIGURE 18 J5 Connector Pin Locations FIGURE 18 XCP2040-TRN I/O Transition Card Manual for Netra CP2040/CP2140 CompactPCI Boards...
  • Page 34 SC2D<5>_L SC2D<4>_L SC2D<3>_L SC2D<10>_L SC2D<9>_L SC2D<8>_L SC2DPL_L SC2D<7>_L SC2D<13>_L SC2D<12>_L MSEN0 SC2D<11>_L Term2_Disable SC2DPH_L SC2D<15>_L MSEN1 SC2D<14>_L I/O2_L REQ2_L C/D2_L SEL2_L MSG2_L BKRST_OUT_L SRST2_L ACK2_L BUSY2_L ATN2_L XCP2040-TRN I/O Transition Card Manual for Netra CP2040/CP2140 CompactPCI Boards • October 2002...
  • Page 35 SCSI parity low byte; provides parity for SCD[0:7] - Active low Select - Active low Request - Active low SRST SCSI bus reset - Active low TRM_PWR Termination power for external SCSI terminator XCP2040-TRN I/O Transition Card Manual for Netra CP2040/CP2140 CompactPCI Boards...
  • Page 36 PIM Card Interface The XCP2040-TRN I/O transition card supports a PMC I/O module (PIM). A PIM is generally located on a transition card to enable rear I/O from the CompactPCI bus chassis. Custom PIMs provide additional I/Os that do not fit on the standard transition card rear panel.
  • Page 37 (not included with XCP-2040-TRN) J4 connector J3 connector PIM A connectors (J0801, J0802) Typical PIM Card and Connectors on XCP2040-TRN I/O Transition Card FIGURE 19 Note – The PIM cards shown in are examples only and are FIGURE 2 FIGURE 19 not included with the XCP2040-TRN I/O transition card shipment.
  • Page 38 Caution – Transition cards built for use with other CompactPCI host boards are not compatible with these Netra boards and might cause damage to themselves, the host, and the backplane if installed. XCP2040-TRN I/O Transition Card Manual for Netra CP2040/CP2140 CompactPCI Boards • October 2002...
  • Page 39 These include USB A and B connectors, SCSI A and B connectors, ethernet A and B connectors and serial port A and B connectors. 5. Install the XCP2040-TRN I/O transition card into the chassis rear connector slot, as described in the following steps:...
  • Page 40 FIGURE 20 cPCI backplane XCP2040-TRN transition card Ejection lever Ejection lever Transition Card Alignment During Installation in Backplane FIGURE 20 XCP2040-TRN I/O Transition Card Manual for Netra CP2040/CP2140 CompactPCI Boards • October 2002...
  • Page 41 Using the ejection levers, gently maneuver the card toward the backplane, without engaging the card socket with the backplane pins. At this point, the card rear flange should project approximately 1/4 in. (6 mm) back from the fully home position. XCP2040-TRN I/O Transition Card Manual for Netra CP2040/CP2140 CompactPCI Boards...
  • Page 42 Reference and Installation Manual (P/N 806-4994-xx) or the Netra CP2140 Technical Reference and Installation Manual (P/N 816-4908-xx). 7. Install the supported peripheral devices at the transition card connector ports as required. XCP2040-TRN I/O Transition Card Manual for Netra CP2040/CP2140 CompactPCI Boards • October 2002...
  • Page 43 Index availability, 9 J3 connector, 22 J4 connector, 24 J5 connector, 25 cables, shielded, 3 compliance, 9 connectors parallel port, 20 backplane interface, 22 part number, 9 on-board, 16 PIM card PICMG specifications, 10 connectors, 18 rear panel, 11 installation, 28 to 29 support, 4 Ethernet connectors, 14 reliability, 9...
  • Page 44 5 environmental, 9 mechanical dimensions, 8 power requirements, 8 USB ports, 12 XCP2040-TRN I/O Transition Card Manual for Netra CP2040/CP2140 CompactPCI Boards • October 2002...

This manual is also suitable for:

06-6743-11

Table of Contents